The Advanced tab of the Preferences dialog contains settings for settings that most users will seldom need and may prefer to keep turned off and tucked away when not in use. This menu is only present in Smaart RT, LE, and Suite, but its appearance varies depending on edition.
Note: LE’s Advanced Preferences menu only contains the Multi-Device TF checkbox. Being the “Limited feature Edition” of Smaart, other advanced options are not present. Any other features discussed here are present in both RT and Suite, unless otherwise noted.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A13Z&se=2026-11-18T17%3A57%3A13Z&sr=b&sp=r&sig=hnuzHC%2BjLw88zWqmMko9TAJk0G099xy2FISGuEBdmuU%3D)
Smaart Suite’s Options > Preferences > Advanced dialog.
Tab & Window Settings
(Smaart Suite Only): Operation Modes (RT, IR, SPL) Open in New Window – When this option is selected, clicking any of the three operating mode buttons on the Control Bar (or invoking their associated menu commands or keyboard shortcuts) in Smaart Suite opens a new window in the selected operating mode instead of switching the current tab to that mode.
Stop Measurements on Tab Change – When this option is checked, Smaart automatically stops all running measurements on a tab when you switch to another tab in the same window. When unchecked, live measurements running on all tabs continue running until you stop them yourself or exit the program. The advantages of allowing background operation are that when you come back to a tab, you don’t have to restart all of your measurements again and wait for their averages to populate. Also, if a remote client is subscribed to the window, then changing tabs on the host machine does not interrupt measurement data being streamed to the client. The caveat is that if you have a lot of measurements running on multiple tabs, a lot of processor cycles can get eaten up crunching data that you are not actually using and performance may suffer as a result.
Transfer Function Settings
Allow Multi-Device Transfer Function lets you select input channels from two different input devices as your reference and measurement Signal sources for transfer function measurements. Please be aware that this will really only work if the sample clocks for the two devices are synchronized somehow, and even then you may encounter issues with relative delay time between the two devices changing when you stop and restart a measurement.
Frequency-Domain Time Windowing (FTW) is a complex linear smoothing technique performed in the frequency domain that is mathematically equivalent to applying a tapered window function to the Impulse Response in the time domain and transforming the result with a zero-padded FFT. FTW is applied globally to all live and captured transfer function measurements that use Complex Magnitude averaging (only). Note turning on this feature forces the global magnitude averaging selection (Mag Avg Type) for live transfer function measurements (see above) to Complex. When FTW is enabled, controls for turning it on and setting the nominal Time Window appear on the Control Bar in the main window. Please see the Frequency Domain Time Windowing for more information.
Sync-Source™ TF (synchronous source transfer function) is real-time transfer function measurement technique that uses a periodic excitation signal (pseudorandom Pink Noise or pink sweep) with a cycle length equivalent to that of the FFT size. When Sync-Source is enabled, controls are added to the transfer function Control Bar in the main window for specifying the Stimulus signal and FFT Length.
L-IFFT™, or Live Inverse Fourier Transform, is an alternate view of the Live IR plot that uses the single time record FFT calculated with every transfer function measurement in Smaart to plot an absolute time referenced live impulse response with the benefits of a real time transfer function measurement applied to it - specifically averaging and magnitude thresholding. When L-IFFT is enabled, a secondary drop down in the Live IR graph allows you to select between Live IR and L-IFFT.
Enable Plot Time Reference (PTR) enables a new control in the lower left of any Phase plot(s). This control is disabled when a live measurement is the top of the Z order. Please visit the Graph Legends chapter for more information on PTR.