Live Inverse Fast Fourier Transform (L-IFFT®) is an alternate view of the Live IR plot that uses the single time record FFT calculated with every Transfer Function measurement to plot an absolute time referenced live Impulse Response with the benefits of a real time transfer function measurement applied to it - specifically averaging and Magnitude thresholding.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A09Z&se=2026-11-18T17%3A37%3A09Z&sr=b&sp=r&sig=ewidySsYPYUhrSj0yDHLc3td4aWuVaV8cRP4pKJB%2Fnc%3D)
Each TF measurement in Smaart is simultaneously calculating an MTW, 32k FFT (by default, other sizes are selectable), and the polar and complex magnitude averaging of each. L-IFFT® takes the single time record complex FFT data and applies an IFFT to get the L-IFFT view. Older data can also be displayed in the L-IFFT® plot only if it was calculated using a single FFT (no MTW data). If the measurement at the top of the Z-order only has MTW data available, the L-IFFT selection is disabled, and nothing will appear in the plot.
Accessing L-IFFT®
L-IFFT® is only available in Smaart Suite and RT. It is accessed by navigating to Preferences > Advanced > Transfer Function Settings and checking the box labeled L-IFFTTM.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A09Z&se=2026-11-18T17%3A37%3A09Z&sr=b&sp=r&sig=uAmRdFZMLFv8sKAA%2BvHMLqgxVwzq%2FIYWFOzO0uNvjKU%3D)
Once enabled, a secondary drop down in the Live IR graph allows you to select between Live IR and L-IFFT.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A09Z&se=2026-11-18T17%3A37%3A09Z&sr=b&sp=r&sig=aM148uutngSgV91AaweLULU%2Bu1PSqGGxSUGqxFkwznY%3D)
Both views offer the standard Lin/Log/ETC graph types.
Bandpass Filter
The same octave bandpass filter used in the Advanced Delay Finder can be applied to the L-IFFT data using the in-plot widget (on the right side of the plot) to both enter the desired filter center frequency and then toggle it on/off via the checkbox.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A09Z&se=2026-11-18T17%3A37%3A09Z&sr=b&sp=r&sig=0FMMUG9Z%2FGjLOpTmUGkIjg7kNXYCz56QNzYRc9AZSDw%3D)
This can be helpful when trying to view the Live IR of a low-frequency driver such as a subwoofer, which normally wouldn’t be visible using the Live IR. When doing this, it can also be helpful to switch to ETC view or use a larger FFT size, the latter of which can be set from within Transfer Function Measurement Settings. While it may take longer for the Delay Finder to lock onto a delay time using a larger FFT size, a benefit of doing this is that it allows more time for lower frequencies to resolve. Performance can further be improved by using a SyncSource measurement Signal.