Measurement Settings (Global)

Prev Next

Spectrum Measurement Settings

  • Data Window sets the data window function, used to precondition time domain signals before performing an FFT for narrowband spectrum measurements (banded spectrum measurements always use a Hann window). The default setting is Hann, which is generally a good place to leave it unless you have some good reason to change it.

  • FFT size (in samples) determines the time constant and frequency resolution of the frequency domain displays. Increasing FFT size provides finer frequency resolution, enabling you to distinguish features more closely spaced in frequency, but does so at the expense of time resolution, the ability to resolve features transient of a Signal that are closely spaced in time. In general, the default setting of 16k is a pretty good trade-off between the two that works well for most applications, given the default Sample Rate of 48k.

  • Averaging Depth specifies the length of time over which individual measurements are averaged to smooth and stabilize the traces or bar graphs on the screen. Bigger numbers give you longer averaging times.


Transfer Function Measurement Settings

General Settings

  • FFT size (in samples) determines the Time Constant and frequency resolution of the frequency Domain displays. When MTW is selected, Smaart performs multiple FFTs and combines the results into a single frequency data set. The individual FFT sizes used in this case are not user selectable. (Suite and RT only)

  • Averaging Depth specifies the length of time over which individual measurements are averaged to stabilize transfer function traces on the analyzer screen and improve their signal-to-noise ratio. Bigger numbers give you longer averaging times.

  • Mag Threshold sets a normalized dBFS value that the reference signal must exceed before new data is accepted into the measurement at any given frequency. When the Magnitude of the reference signal does not cross threshold at some frequency, new incoming data at that frequency is excluded from the average.

Live IR & Delay Tracker

  • FFT Size sets the FFT frame size (in samples) for the Live IR display. The resulting time constant, based on the current sample rate setting in Audio Options, is calculated and displayed for each available FFT size.

  • Averaging sets the number of averages used for the Live IR display. Increasing this value may provide a more stable display at the expense of responsiveness. Increasing this value will also give you a better chance of capturing a usable Live IR measurement when measuring under difficult conditions.

Delay Finder

  • FFT size and Averages- The default is a 64k FFT with no averaging, which works out to a time constant of 1365 ms at 48k sample rate. This is sufficient for finding delay times at distances up to about 450 feet (140 meters) from a source. A good rule of thumb is that the FFT time constant should be least three times greater than the expected delay time. When measuring from extremely long distances or using a sample rate greater than 48k, you may need to increase the FFT size. When working in very noisy surroundings, increasing the number of averages may help as well.

  • Increment allows you to set how much delay is applied with each press of the + and - buttons on your Transfer Function measurement engine.