The All Bands table in Smaart collects reverberation times and early-to-late energy ratios for all octave and 1/3-octave bands in a single table. Speech intelligibility metrics (STI, STIPA, and %ALCons) are displayed here as well. The Histogram chart can plot any column of the All Bands table as a bar graph or line chart in octave or 1/3-octave resolution.

Enabling the All Bands table via the Control Bar button.

The All Bands Table.

Clicking the All Bands button at the bottom of the IR mode Control Bar brings up a report window. This window contains just about every acoustical quantity that Smaart can automatically calculate from an IR, for each octave and 1/3-octave band, where applicable. Bass Ratio, T Mid, and T Low are calculated automatically from reverberation times for the 125 Hz to 4 kHz octave bands.

You may notice in these screenshots that some values are marked in red. This happens when Smaart detects there isn’t enough integration time in the measurement at those bands to calculate a T value. This generally happens when the Impulse Response is not sufficiently above the noise floor and can be improved by using more averaging in the measurement, longer FFT sizes, turning up the stimulus, manually adjusting the Ln positioning, or often a combination of each. Smaart calculates Ln and the other RT60 integration values automatically, but it requires a good measurement to get good data.

Older versions of Smaart also include the %ALCons metric, a precursor to STI and STIPA. This metric, however, was never standardized and, due to its controversial nature, it is absent from Smaart versions v9.7 and newer. When multiple IR measurements are displayed, the All Bands table analyzes the top trace and will recalculate if the z-axis order of the main graph is changed while the All Bands window is open.

Smaart can calculate STI from Impulse Response measurements provided that the Time Window is at least 1.6 seconds (though 5+ seconds is preferable), given some additional information about the measurement. If that information has been previously provided and stored in the header of an IR wave file being analyzed, the STI, STIPA, and CIS fields in the All Bands Table populate automatically. Otherwise, you can click the Calculate STI button to fill in the necessary details (see Calculating STI for details).

Clicking the Copy button in the All Bands window copies the entire table to the operating system’s clipboard in tab-delimited ASCII format suitable for pasting into a spreadsheet or any other program that accepts ASCII text. You can also save the information in this window to a text file by clicking the Export button.