IR Mode Control Bar.
The Control Bar in Impulse Response mode is home to the in-tab SPL meter/Clock and includes live measurement controls, bandpass filters Signal generator and main display controls. The Control Bar and in-tab SPL Meter (when present) can be shown or hidden by pressing the [O] key on your keyboard or selecting Control Bar from the View menu. When hidden, a triangular button appears in the right border of the window and clicking this button will restore it.
The in-tab SPL Meter/Clock can be hidden independently of the Control Bar. You can also change it to a clock by pressing the [K] key on your keyboard or selecting Toggle SPL/Clock from the View menu. To hide this display completely, use the SPL Meter command in the View menu or press [Alt/Option] + [K] on your keyboard. For more information about the in-tab SPL Meter/Clock, please refer to the SPL Meter/Clock article.
Live Measurement Controls
The next section below the SPL Meter/Clock houses live measurement controls for recording impulse response measurements in the field. Note that you can also analyze file-based data in impulse response mode.
Dual-Channel Measurement Settings
The FFT size and averaging (Avg) controls together determine the measurement duration for dual-channel impulse response (IR) measurements. Notice that for each FFT size, the Time Constant is given along with the FFT size in samples. The FFT time constant, also called the measurement "Time Window," is the amount time it takes to record the required number of samples for a single FFT frame at the currently selected Sample Rate.
The Averages (Avg) selector sets the number of successive IR measurements to average together to improve the signal-to-noise ratio of dual-channel measurements. When measuring with random signals or in noisy environments, more averaging can significantly improve the signal-to-noise ratio of impulse response measurements. For deterministic IR measurements made using period-matched signals, the number of averages is normally set to a low number or even “None”. Note that overlapping successive measurements (by setting Overlap % in the General Options section of Impulse Response Options to a number greater than 0) will generally reduce the noise reduction benefit of any given number of averages.
IR Measurement Controls
The row of buttons below the FFT size and Averaging selectors control the capture of new IR measurements and determine their type. The button labeled with a circle (●) works like the record button on a tape deck or digital recorder, but in this case, it is a measurement type control. Clicking the run/stop (►) button (or use the hot key [Shift] + [R]) without the record button punched in triggers a dual-channel IR measurement using both input channels of each selected "measurement engine" (see below). Smaart records the specified number of FFT frames at the selected FFT size for each selected measurement pair and then calculates and displays the results when finished. Clicking the run/stop (►) button while the measurement procedure is running cancels the measurement. The button labeled with the hammer and wrench icon opens the Measurement Config page.
With the record button (●) activated, Smaart becomes a single-channel digital recorder and records just the measurement signal channel(s) of selected measurement engine signal pairs. The idea is that you would start the recording and pop a balloon or fire your starter pistol (or whatever), and then click the run/stop (►) button again to end recording and display the results.
The Continuous (Cont) button causes dual-channel measurements to run continuously, starting over again automatically each time it finishes a measurement until you tell it to stop (by clicking the stop button). The results of the last measurement are displayed while it’s recording and processing the next measurement. Click the run/stop (►) button again to stop the measurement.
Measurement Engines
Dual-channel IR measurements in Smaart are essentially Transfer Function measurements (followed by an inverse Fourier transform) and so any of the transfer function signal pairs that you have set up in the current tab for real-time (frequency-Domain) transfer function measurements may also be used in any combination for IR measurements. The check box in the upper right corner of each measurement engine's control block determines whether or not it is included when capturing a new IR measurement – if left unselected, the measurement engine is ignored. After capturing a new IR, clicking the circular button to the right of the delay field in any active (checked) measurement control block sets its delay time to the highest peak found in the new measurement.
Note that new IR measurements are initially stored only in memory. Any previous unsaved measurement data captured for selected measurement engines is replaced by new date when you run a new measurement. To save new measurements to .wav files, click the Save or Save All buttons on the Data Bar.
The "+ TF Engine button below the live measurement control blocks does the same thing as the New TF commands in the Config menu. Creating a new transfer function measurement engine also creates a new Impulse Response mode measurement engine to match.
The View button opens a menu for selecting View Presets, which also includes main display control buttons for allocating the main graph area (à la Smaart 7 and 8, in case anyone misses them), show/hide buttons for the Data Bar, Tab Bar, Control Bar, and Command Bar, and a Tab selector drop list in case the tab bar is hidden. The Timer button opens the settings page for timed measurements however timed measurements are currently not available in Impulse Response mode.
Bandpass Filters
The broadband impulse response is useful for finding delay times and discrete reflections, but for most acoustical analysis purposes, the IR needs to be filtered into octave bands or sometimes 1/3-octave bands. Smaart includes complete sets of octave and 1/3-octave bandpass filters for impulse response analysis. Bandpass filtering is non-destructive and is done on the fly whenever you need it. All you have to do is select the filter set that you want to use (Octave or 1/3-Octave) using the Filters selector on the Control Bar and then choose the center frequency for the band that you want to analyze from the Band list. Smaart's octave and 1/3-octave band filters are linear Phase with Magnitude response conforming to IEC 61260-1:2014 Class 1 specifications.
In addition to the conventional octave and 1/3-octave bandpass filter, there is a user-defined bandpass filter option. When selected, a pair of input fields appear to specify cut-off frequencies for the high-pass and low-pass filter. These are the same filters that can optionally used for band-limiting the broadband IR (see Impulse Response Options) but settings for the user-defined bandpass filter are maintained separately. The high pass and low pass filter have linear phase response and are designed to approximate 6th-order Butterworth magnitude response in the pass band but have steeper roll-off in the transition band. The low-pass filter is based on a bi-linear transform design and will effectively increase in order at frequencies approaching Nyquist. The minimum bandwidth for the user-defined filter is one octave. When the high-pass and low-pass filter cut-off frequencies are set exactly one octave apart they form a bandpass filter conforming to EC 61260-1:2014 Class 2 magnitude response specifications.
Signal Generator Controls
The next group of controls on the Control Bar is for the signal generator. The label at the top of this section is actually a hover button (it turns into a button when your mouse cursor passes over it) that opens the Signal Generator dialog, which contains a lot more options for the signal generator than we could fit on the Control Bar. Below are a signal type selector (Pink Noise is selected in the example to the right) and an output level field that shows the current output level in normalized dB Full Scale. The On button turns the generator on or off – it glows an angry red when the generator is running. The minus and plus (−|+) buttons to the right of the output level field bump the signal level down or up by 1 dB.
Display Controls
The last group of controls consists of six buttons.
The All Bands button opens the All Bands table, where you will find nearly all of the quantitative acoustical metrics that Smaart can calculate automatically for an impulse response. See Histogram and All Bands Table for more in this feature.
Clicking the T60 button displays level marker widgets used for calculating Reverberation Time and early decay time on Log IR or ETC plots.
The Schroeder button displays a reverse time integration curve on Log IR or ETC plots.
To exit Impulse Response mode, click either the Real-Time or SPL mode selector buttons above the control bar.