Histogram Display

Prev Next

Selecting Histogram as your display type for an IR mode graph plots a chart of all reverberation times or early-to-late energy ratios by either octave or 1/3-octave bands. The type of data the Histogram displays and the resolution are selected by means of the list control in the upper left corner of the graph. You can change the Histogram to a line chart by opening Graph Settings > Impulse Response and selecting Lines under Histogram Settings.

Smaart’s Histogram plot and All Bands Table.

The All Bands Table in Smaart collects reverberation times and early-to-late energy ratios for all octave and 1/3-octave bands in a single table. Speech intelligibility metrics (STI and STIPA) are displayed here as well.  The Histogram chart can plot any column of the All Bands Table as a bar graph or line chart in octave or 1/3-octave resolution.