The Data Bar in Impulse Response mode works almost exactly like the Data Bar in real-time mode but with a few exceptions. Here we have only one data file type to contend with – IR measurements, which are stored as .wav files. IR Mode’s Data Bar menu commands are a subset of the Real Time mode Data Bar menu commands. Menu commands that are not applicable to impulse response data are simply greyed out, as shown below:
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A11Z&se=2026-11-18T17%3A41%3A11Z&sr=b&sp=r&sig=hNJU4D9OSYZoDiqJJaAPlQf1LclqwEtHOnoPz9trLeQ%3D)
Smaart can read standard .wav files from almost any source, but IR measurements created in Smaart have extended information stored in the .wav file headers that tell us some things we would not know otherwise. These attributes can be viewed in the Trace Info dialog, which is generally a subset of the Real-Time mode Trace Info dialog with a single exception: the inclusion of an Import button. The Import button will import decay marker positions used to calculate RT60 reverberation times. Smaart can also store user-selected decay marker positions in the header of IR .wav files.
Previous versions of Smaart (optionally) stored these coordinates in separate companion files in comma-separated values (.csv) format, requiring you to import the marker position file each time you loaded the .wav file.

To write decay marker positions from an external .csv file to the header of a legacy IR data file, click the Import button in Trace Info, navigate to the location of the maker position file and open it, then click the OK button in the Trace Info dialog.