The Data Bar provides easy access to captured measurement data. It can be shown or hidden by pressing the [B] key on your keyboard or selecting Data Bar from the View menu. When hidden, a triangular button appears in the left border of the window and clicking this button will restore it.
The Data Bar contains captured “snapshots” of real-time frequency-domain data traces known as “reference traces.” The type of data files shown on the Data Bar will depend on the current active graph selection. The Data Bar shows you only one type of data at a time, depending on the active graph selection in the graph area.
Smaart’s Real-Time Mode (Suite, RT, LE) shows one of two options depending on view:
When in Spectrum View, the Data Bar shows RTA traces in .srf format.
When in Transfer Function View, the Data Bar shows Transfer Function traces in .trf format.
Smaart’s SPL Mode (Suite, SPL) Data Bar shows SPL logs in .txt format.
Smaart’s IR Mode (Suite only) Data Bar shows Impulse Response measurements in .wav format.
The heading at the top of the Data Bar tells you which type of Smaart data files are currently shown. The (three-line) menu button in the upper right corner of the Data Bar a opens a menu of actions applicable to captured measurement data. This menu, along with the right-click (or [Ctrl]+click on Mac) context menu for the Data Bar, is covered in detail in the Data Bar Menus article. There is also a search bar that allows you to filter the data library based on your text entry. The filter is applied automatically as you type; to remove the sorting filter, simply delete the text entry or click the X icon to the right of the text.
The center portion of the Data Bar lists the files and folders in your current data library folder that match the active graph type. Each file icon is colored to match the display color for the data trace stored in the file. An “X” appears in the icons for files that are currently not being displayed on the active graph.
You can organize your data files using folders and drag files from one folder to another, much as you would in any file system window on your computer, and you can drag files from the data bar onto a compatible graph in the graph area to display them. Notice that one folder is always “pinned” to the top of the library pane. We refer to this folder as the “session folder.”
The session folder is the destination for new data captures and any new folders you create during your current Smaart session. You can change the session folder by clicking the (three-line) menu button in the upper right corner of the Data Bar and selecting New Session Folder from the menu, or by dragging an existing folder to the top position in the data library pane with your mouse and then releasing the mouse button. Creating a new session folder automatically changes the session folders for both {{glossary.Spectrum}} and transfer function data and the previous session folders become ordinary file folders. Dragging and dropping an existing folder to make it the session folder works similarly, except that the change applies only to the current data type.
At the bottom of the Data Bar are two buttons: Info and Delete. The Info button opens the Trace Info dialog for a selected data file, where you can review and edit file properties. You can also open Trace Info for a selected trace by pressing the [Enter] key on your keyboard. The [Esc] key can be used to close the dialog when it is open. Please refer to Trace Info Dialog for more details. The Delete button permanently deletes a selected file, folder, or group of objects selected in the library pane. You can select multiple files in the library pane, either by holding down the [Ctrl/Cmd] key while clicking on file icons with your mouse (to select an arbitrary group of files) or you can hold down the [Shift] key while selecting a contiguous range of objects. Note that deleting a folder automatically deletes all of the files and folders that it contains.
Working with Captured and Imported Data
Smaart has the ability to capture and display static “snapshots” of live spectrum, transfer function, and impulse response measurements as data files for later reference. Smaart v9 can open and display captured spectrum (.srf) and transfer function (.trf) data files from Smaart v7 and newer. You can also create Smaart RTA and transfer function data files by importing data in ASCII text format.
Captured and imported data traces are written to files in the designated session folder and will immediately appear in data library pane on the Data Bar. More information on Real Time Mode’s Data Bar’s menus cane be found here. Alternatively, information on Impulse Response Mode’s Data Bar can be found here.
Capturing Data from Live Measurements
You can capture new data trace files from live measurements on the active graph in the graph area by clicking the Capture or Capture All buttons. The Capture command (keyboard shortcut: [Spacebar]) captures the active live measurement on the active graph. Capture All ([Shift] + [Spacebar]) captures all currently running measurements that match the active graph type.
When capturing a single trace you will be prompted for a file name. Capture All prompts you for a folder name and then uses the names of the real-time measurements being captured as the filenames for the corresponding trace files.
Captured data files in the data library that are not currently displayed on a graph have an “X” drawn on their file icons. To display a hidden file or hide one that is visible, click its icon. Clicking on a data file’s name in the data library pane selects/highlights it. If the file is unhidden, this will also bring it to the top of the z axis on the active graph in the graph area. For details about a selected file, press the [Enter] key on your keyboard or click the Info button on the Data Bar to open the Trace Info dialog.