The small time-Domain display in the upper part of the IR mode graph area is used for navigation and is always visible. The on-graph in the upper-left corner of the navigation pane selects the graph type to be displayed in this area. The navigation pane is limited to time-domain graph types only (Lin, Log or ETC).
Right-clicking ([Ctrl] + click on Mac) and dragging across this panel selects a specific time range for display on the larger time-domain charts. The full IR time record remains visible in the navigation pane when zoomed in (unless you use the crop function). Clicking anywhere in the left margin of the plot clears the zoom range and returns any time-domain graphs in the main display pane(s) to the full IR time record.
The crop button in the lower-right corner of the navigation pane can crop a file for display purposes to show only the selected time range – a very useful feature when working with IR measurements with long noise tails. Cropping is non-destructive and can be undone – clicking the crop button again on a cropped measurement restores the full extent of the original time record – however if you save the IR to a file while cropped, the cropped version is written to file.
The small, arrow-shaped widget positioned in the lower-left corner of the navigation pane (circled in red in the screenshot to the right) is the Time 0 marker. When you record a dual-channel Impulse Response measurement in Smaart, this marker is automatically set to match the reference Signal delay time – if you are familiar with real-time Transfer Function measurement, this is analogous to the center point of the Live IR display. For single-channel measurements or file-based data, Time 0 is set to the beginning of the time record. Dragging the marker to the left or right moves the time-zero point for all time-domain graphs (Lin, Log or ETC) displayed in the main graph area.
In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays.
The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function.
Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time.
The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response.