The real-time Spectrum analyzer, or RTA, is a familiar tool to most audio professionals and probably needs little introduction. It enables you to look at the frequency content of signals in real time. Essentially the RTA is a graph of the energy in an incoming Signal that’s been broken down by frequency or frequency ranges. This graph has frequency in Hertz (Hz) on the x axis and Level (energy) in decibels (dB) on the y axis. When one or more live spectrum measurements are running, the graph is updated continuously to produce a real-time display. By adjusting the scale and averaging of the display, we can refine measurement resolution and responsiveness to fit different tasks.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T17%3A43%3A07Z&sr=b&sp=r&sig=iQka7Wy93ypjsGvSvr80iiJ%2FTCOfprjnN2oaf036Qoc%3D)
RTA plot with No Banding (top left), Octave Banding (top right), 1/12 Octave Banding (bottom left), and 1/48 Octave Banding (bottom right).
In spectrum analysis, time resolution and frequency resolution are a trade-off, you can't maximize both at once. The FFT size is a core consideration that, fortunately, you should not have to spend much time thinking about - the default setting is a 16k FFT which gives a good balance between frequency resolution and responsiveness. Larger FFT settings are available and will give you finer frequency detail, especially at low frequencies, but they will also take longer to process, making the display slower to react to changes in the signal. RTA detail and responsiveness are further shaped by two additional settings: averaging and banding.
Averaging and Banding Controls
The RTA display typically averages data from successive incoming FFT frames over a period of time. This produces a display that is smoother, and less jumpy. Averaging also limits how quickly the RTA can respond to rapid changes in the frequency content signals. Unlike banding which is a display function that can be changed anytime, the FFT size and averaging settings used are baked into RTA data at the measurement level – capturing an RTA trace means capturing averaged data (if applicable) and the FFT that was calculated. Spectrum averaging, however, affects only data on the RTA plot. The Spectrograph is always plotted from instantaneous (non-averaged) spectrum data.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T17%3A43%3A07Z&sr=b&sp=r&sig=q%2Fv6%2BVnC%2Fd8No3uX41BgctPxchiHDKN5X12WD062vUM%3D)
Live measurement controls for Spectrum measurements.
Banding is a display parameter for Spectrum data. When you capture a snapshot of an RTA trace, you are capturing it at the original FFT resolution and can always change the banding after the fact. Using larger fractional octave bands can help reduce visual “noise” and make larger trends in the spectrum of a signal more obvious, but at the expense of limiting how much detail you can see.
The Banding setting can be adjusted from the bottom-right corner of the Spectrum plot. The Averaging setting, however, is adjustable from the Control Bar. Banding is a global setting that applies to all spectrum measurements. Averaging applies only to the RTA display and can be set specifically for individual spectrum measurements. If the current active measurement uses the global setting for spectrum averaging then the Averaging selector on the Control Bar controls the global setting. Otherwise, it applies only to the active measurement.
RTA Graph Types
Spectrum data is most commonly displayed as a bars with fractional-octave frequency scaling. However, Smaart can also display banded RTA data as a line graph or a combination of fractional octave data in bar chart form with the un-banded FFT data overlaid as a line graph. Un-banded (aka “narrowband”) FFT data, however, is always plotted as a line graph. These three options (Bars, Lines or Both) can be toggled within the RTA Display Settings section of the Spectrum Graph Settings dialog.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T17%3A43%3A07Z&sr=b&sp=r&sig=Fo6B4LyF%2FJWkpZwJJxBz3bIdproXcb9T95guPpk0OX4%3D)
RTA plot showing data as bars (left), lines (middle), and both (right).