Weighting curves are how we shape the frequency content of our measurements in Smaart. They are used in real time mode to shape the Magnitude Spectrum of live or stored measurement data. Another way to put it might be to say that filtering in the time Domain equates to weighting in the frequency domain. Weighting curves can be applied to all real-time frequency/magnitude charts in Smaart including RTA, Spectrograph and Transfer Function Magnitude plots.
Weighting curves are also used in Sound Pressure Level (SPL) measurements. For more information about SPL weighting, take a look at it’s dedicated article: Frequency Weighting
How to Apply a Weighting Curve
To add a weighting curve globally to a live spectrum or transfer function plot, open the Graph Settings dialog by clicking the gear icon to the bottom-right of the plot. Here you will see a Weighting setting accompanied by a dropdown menu and a Display Weighting checkbox. This setting can also be set individually for each measurement engine separately in Measurement Engine Settings (both for Spectrum and Transfer Function measurements).
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T17%3A44%3A08Z&sr=b&sp=r&sig=nrOx0e5gKMzAybmSUiIJQUk11SQm570uop4La%2F069qI%3D)
Weighting selection in both Spectrum (left) and Transfer Function (right) Graph Settings.
To add a weighting curve to a captured data trace, use the Weighting selector in the Trace Info dialog. You can open Trace Info for a selected file using the Info button at the bottom of the Data Bar or by right-clicking said file and select Info.
Custom Weighting Curves
By default, Smaart includes A, C, X, and Pink weighting curves both in their standard forms and as inverted variants. User-defined weighting curves can be created from a captured transfer function trace or imported as an ASCII-formatted .txt file.
How to Import Weighting Curves
To import a weighting curve stored in an ASCII .txt file, select File > Import > Weighting Curve or open the Custom Weighing Curves dialog (Options > Weighting Curve) and then click the Import button. Either option will open your operating system’s file browser so that you can find your custom weighting curve file and open it to import the curve data.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T17%3A44%3A08Z&sr=b&sp=r&sig=2QSNvIOtqC%2Bzyt8ujlj7kY%2BZf0Df6D9IOf2KVUtBRJs%3D)
The Custom Weighting Curves dialog.
Weighting Curve Formatting
Weighting curve text files need to be in ASCII text format: two columns of data in Frequency[Tab]Level (dB) format. Smaart will ignore lines beginning with an asterisk (*) or semicolon (;) so these may be used to add human readable headings or comments above these two columns of data.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T17%3A44%3A08Z&sr=b&sp=r&sig=PIqPD0479WhDSBs4NkI2%2Ff2R%2BHBpgGfmQ19Bz3kEHro%3D)
Example weighting curve formatting.
Export Captured Transfer Function Trace as Weighting Curve
To export a transfer function trace as a weighting curve, select it on the Data Bar, click the hamburger menu (☰) button, and select Export as Weighting Curve. Alternatively, you can right-click the desired trace and select Save As > Weighting Curve. Doing either causes a dialog to appear, allowing you to name the new weighting curve.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T17%3A44%3A08Z&sr=b&sp=r&sig=zLK2VoIQ9tY2vmGcDfYvoDv%2FdXurWXY5asAgPZQvPWQ%3D)
New Weighting Curve dialog.
Clicking OK in this New Weighting Curve dialog will add the new curve to the Weighting dropdown list. Smaart automatically creates an inverted version of the curve as well and appends the notation “Inv” to its name.
Delete Weighting Curve
To delete a custom weighting curve, select Weighting Curves from the Options menu to open the Custom Weighting Curves dialog, then click the name of the curve that you no longer want and click the Delete button. Deleting a weighting curve removes both the normal and inverted versions.
The standard A and C (sound level) weighting curves are hard coded in Smaart and cannot be deleted.