Spectrum Graph Settings

Prev Next

The Spectrum page of the Graph Settings dialog is devoted to global display settings for all RTA and real-time Spectrograph plots. It is accessible by selecting Options > Graph Settings > Spectrum, using the [Alt/Option] + [S] hot key, or by clicking the settings button () in the lower-right corner of any Spectrograph or RTA graph in any main window graph area.

Spectrum Graph Settings.

General Settings

  • Frequency Scale – The frequency scale selector sets frequency scaling and grid ruling options for the RTA display. Actually, there are only two real scaling options: linear (Lin) and logarithmic. All of the other options in this list are grid-ruling options for log-scaled frequency.

    • Decade plots the RTA graph with logarithmic frequency scaling and decade (base 10) vertical grid ruling.

    • Octave plots the RTA graph with logarithmic frequency scaling and vertical grid lines spaced at one-octave intervals.

    • 1/3 Octave plots the RTA graph with logarithmic frequency scaling and vertical grid lines spaced at 1/3-octave intervals.

    • Lin plots the RTA graph with linear frequency scaling and linearly spaced vertical grid ruling.

  • The Weighting control assigns a global weighting curve to spectrum graphs. Smaart has built-in curves for A and C weighting curves used in SPL and Leq measurements with normal and inverted versions of each. You can also create your own weighting curves from transfer function data traces or by importing ASCII text files. See Weighting Curves for more about custom weighting curves.

    When Weighting is set to something other than None, the state of the Display Weighting control determines whether an interactive drop-list control appears on RTA plots, enabling you to change the weighting setting directly from the graph in the main window. Note that this control is disables when un-checked if Weighting is set to None.

  • Link Plot Banding – when this box is checked, the banding controls for all spectrum (RTA and Spectrograph) graphs are linked, so that changing the banding setting on graph automatically changes banding on all other spectrum graphs in all tabs and windows to match.

  • Link Plot Zoom – when enabled, all plots of the same measurement type with a common axis share zoom. When disabled, each plot zooms independently.

RTA Display Settings

  • The Banded Data setting determines the type of chart used for octave and fractional octave band RTA displays.

    • Selecting Bars plots banded RTA graphs as a bar chart.

    • Selecting Lines changes the banded RTA display to a line graph.

    • The Both option is a hybrid display that superimposes a narrowband spectrum trace over a fractional-octave banded bar graph.

  • Track Peak causes Smaart to track and display the magnitude and frequency of the data point with the highest magnitude in the front trace on the RTA plot.

  • When Show THD is enabled and the RTA graph is set to a fractional-octave banding resolution of 1/12th-octave or higher, the notation THD: n%, will appear in the cursor tracking readout above the RTA graph, where n is the THD percentage value calculated for the current cursor frequency. THD values in Smaart are the ratio of the power in the fractional octave band at the cursor frequency, to the sum of the power in the next three harmonic frequencies. If (and only if) the cursor is positioned at the frequency of a single sine wave being used to stimulate the system under test, this value should be indicative of the total harmonic distortion present in the system at that frequency. Otherwise, it is generally meaningless.

  • Plot Calibrated Level applies input calibration offset (e.g., for SPL calibration) to RTA measurements (if applicable) and makes the default RTA display range 20 dB to 120 dB. Note that this will result in a drastic difference in scale between data from inputs calibrated to SPL and inputs calibrated to digital Full Scale. When this option is not selected, Smaart ignores input sensitivity calibration and references all spectrum measurements to digital Full Scale. The default magnitude range for RTA displays in that case is 0 to −100 dB.

  • Magnitude Range (dB) sets the default decibel range for the y axis of the RTA graph. When you zoom the plot using mouse or keyboard shortcuts, you can reset the plot to the default magnitude range by clicking anywhere in the margins of the graph with your mouse.

  • The Line Thickness controls set the line thickness for RTA traces when viewed as Lines.

    • Foreground Trace – sets the line thickness in pixels for the data trace at the top of the z axis (the frontmost trace) on all line charts.

    • Background Trace – sets the line thickness in pixels for all data traces other than the top trace when multiple traces are displayed on any line chart.

  • Banded Data displays a line or series of bar segments (depending on the Banded Data setting above) at the peak magnitudes measured for each frequency point on the RTA graph. The peak hold function has the following options.

  • The Peak Hold checkbox turns RTA peak hold on. The following settings control the behavior of the RTA peak hold display.

  • Peak Type sets the time decay type for RTA peak hold:

    • Timed peak hold allows the peak trace to decay after some period of time, as specified in the Hold field (see below).

    • Infinite peak hold preserves the highest peak level recorded for each frequency until it is replaced by a higher reading or you turn the feature off or press the [V] key to flush the averaging buffers.

  • Hold – this field sets the decay time for Timed peak hold in seconds.

  • Averaged peak hold bases the peak hold trace on averaged RTA data when selected (if applicable). Otherwise, the peak hold function looks for the highest peaks in each incoming FFT, before the data goes into the average for the regular RTA display.

  • Y-Zoom Increment (dB) sets the increment used for keyboard zoom on the y axis of the RTA graph. When an RTA display is selected in the plot area pressing the [+/=] or [−] keys will increase or decrease the vertical scale of the graph by the number of decibels specified here.

  • Y-Scroll Increment (dB) sets the increment for keyboard scrolling on the RTA or Spectrograph displays. When an RTA or Spectrograph display is selected in the plot area, each press of the up arrow [↑] or Down arrow [↓] keys will scroll the plot up or down by the number of decibels specified.

  • Y-Grid Interval (dB) sets the y-axis grid-ruling interval for the RTA graph in decibels.

Spectrograph Settings

  • Slice Height sets the height in pixels for each row in the Spectrograph display.

  • Slices in History sets the maximum number of rows for the spectrograph history. This can exceed the number of rows you are able to display on your screen at a given time, allowing you to scroll back to see transient events or other features that have scrolled off the screen. The caveat is that the more rows in the history, the more memory is required. For large FFT sizes and very long histories, the memory requirements can be quite large

  • Max Memory Required shows you memory requirements for the specified spectrograph history size, based on the current FFT size selected for spectrum measurements in I-O Config.

  • Dynamic Range (dB FS) sets the upper and lower (Max and Min) boundaries for the spectrograph display in decibels. Frequency data points whose magnitude values fall below the specified minimum (Min) value are displayed in black. On the high end, out-of-range values that exceed the specified Max value are set to white.

  • Grayscale changes the spectrograph to shades of gray, rather than colors.