Real Time Mode Control Bar

Prev Next

The Control Bar in real-time mode is home to live measurement controls for the active graph and signal generator. The Control Bar and in-tab SPL Meter (when present) can be shown or hidden by pressing the [O] key on your keyboard or selecting Control Bar from the View menu. When hidden, a triangular button appears in the right border of the window and clicking this button will restore it.

In Smaart Suite, three mode selector buttons appear above the control bar for switching between main display modes: Real-Time, Impulse Response, and SPL mode. You could say that Smaart RT and LE are always in real-time mode and Smaart SPL is always in SPL mode. In this topic, we will talk about the real-time control bar.

The in-tab SPL Meter/Clock can be hidden independently of the Control Bar, to make more room for live measurement controls. You can also change it to a clock by pressing the [K] key on your keyboard or selecting Toggle SPL/Clock from the View menu. To hide this display completely, use the SPL Meter command in the View menu or press [Alt/Option] + [K] on your keyboard.


Live Measurement Controls

The main section below the SPL Meter/Clock contains live measurement controls for the active graph (see Graph Area for more info). When the active graph is an RTA or Spectrograph, this area contains controls for Spectrum measurements. If the active graph is a Transfer Function, Magnitude, Phase Shift or Live IR graph, transfer function measurement controls appear here.

Control blocks for two spectrum measurements and one live average.

The label at the top of this section indicates which type of display (Spectrum or Transfer Function) is currently active. Notice that the label becomes a button when the mouse cursor hovers over it. Clicking this button opens the Measurement Settings dialog to the Spectrum or Transfer Function tab, depending on the current active display selection.

The Averaging control this section applies to the active live measurement, which is to say, the front-most live measurement on the active graph. The current active live measurement selection is indicated by the background color of its control block in the lower portion of the control strip. In the example shown here, measurement labeled “Mic 1” is active.

If the current active measurement uses the global settings for averaging, banding or smoothing (as applicable), changes to these settings will affect all measurements of the same type (unless otherwise specified). If the current active measurement is not subscribed to the global selections for a given setting, then the selector affects only the active measurement. A measurement engine’s parameters can be set independently from the global settings via the Spectrum Measurement Engine Settings fly-up menu. To access the fly-up, double-click the measurement engine you’d like to make changes to.

Below the active Averaging selector are tab-level measurement controls and individual control blocks for live measurement engines. Both spectrum and transfer function measurements have Stop All (■) and Run All (►) buttons that turn all measurements in the tab off or on as well as a Pause All button ( ▌▌). Note that the Stop All and Run All buttons are one-shot operations (clicking them a second time doesn't do anything) whereas the Pause All button latches; You click it once to pause and again to resume.

For transfer function measurements, the Track button turns delay tracking on for every measurement in the tab. The button to the right of it (with the stopwatch icon) triggers a timed measurement. The button labeled with the hammer and wrench icon opens the Measurement Config page.

The lower portion of the live measurement controls section is a scrollable area containing the control blocks for each individual measurement in the tab. If you have more measurement configured than can fit here, a scroll bar appears so that you can scroll through the list. The control blocks differ somewhat depending on the measurement type.

Live average control blocks (spectrum or transfer function) are the simplest. These consist of just the name of the measurement, a round Show/Hide button and a triangular Run/Stop button (►). The color of the Show/Hide button and the border color of the control block match the display color for the associated data trace on applicable graphs and their associated icons in Graph Legends. These elements are common to all types of live measurements.

Control blocks for two transfer function measurements and one live average.

To the above, we add an input level meter for single-channel spectrum measurements. Dual-channel transfer function measurements have two input level meters (labeled “M” and “R” for measurement and reference channel), a delay time field, and a delay-tracking indicator (●). You can click on the delay time field to make it editable and type in a new delay time (in milliseconds), then press the [Enter] key.

When a dual-channel transfer function measurement is the active measurement, an additional row of hover buttons appears below the base control set, labeled Find, Track, and −|+. The Find button starts the Delay Finder for the selected measurement, an automated routine for finding delay times for Signal alignment (see Activate Delay Finder for more on this). The Track button turns on delay tracking, which actively re-measures and adjusts measurement signal delay on each new update of the measurement – you can also turn delay tracking on and off by clicking the tracking indicator (●). The minus and plus (−|+) buttons decrease/increase the delay time for the measurement by one increment as specified in Transfer Function Measurement Settings. The default is one sample (about 21 microseconds per click at 48k Sampling Rate).

Clicking the Run button (►) for a live measurement starts the measurement, clicking it again when the measurement is running stops it. The run button turns green when the measurement is running and gray when it is stopped. Note that when you start a live average, at least one of the measurements that make up the averaged measurement must also be running in order to see any data on the graphs.

Notice that when you stop a live single-channel or dual-channel measurement, Smaart automatically hides it. If you unhide a stopped measurement, you will see the last data that it acquired on applicable graphs. This can be a handy way of “freezing” a trace for closer inspection without capturing a stored data trace.

The + Spectrum Engine and + TF Engine buttons below the live spectrum and transfer function measurement control blocks do the same thing as the New Spectrum and New TF commands in the Config menu. The View button opens a menu for selecting View Presets, which also includes main display control buttons for allocating the main graph area (à la Smaart 7 and 8, in case anyone misses them), Show/Hide buttons for the Data Bar, Tab Bar, Control Bar, and Command Bar, and a Tab selector drop list in case the tab bar is hidden. The Timer button opens the Timer Macro settings page.