Reverberation time is calculated from the reverse integration of an impulse response that has been filtered into octave bands. Conventionally, the 125 Hz to 4 kHz bands are evaluated. Reverse time integration is also called Schroeder integration, after Dr. Manfred Schroeder whose brainchild it was. Clicking the Schroeder and T60 buttons at the bottom of the IR mode Control bar will plot the reverse time integration and level markers for calculating reverberation time on logarithmic time domain graphs (log IR or ETC).
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A00Z&se=2026-11-18T17%3A43%3A00Z&sr=b&sp=r&sig=k7b9UXaQagU1R6bRiD93lVIBbZy106UlWYluFkPI%2B38%3D)
Level Markers applied to an IR measurement
Notice the five level marker widgets shown on the plot in the figure above. These are turned on and off by the T60 button on the Control Bar. When multiple IR measurements are displayed, the level markers and reverse integration curve for the top trace (only) are shown.
To calculate reverberation time the level markers are conventionally positioned on the reverse integration curve as follows:
Ld = Level Direct. This marker is positioned on the reverse integration curve at the point corresponding to the arrival time of direct sound.
Le = Level Early (Decay). This marker is automatically positioned 10 dB down from the Ld marker on the reverse integration curve. The slope between Ld and Le is used to calculate EDT.
Lr1 = Level Reverberant 1. This marker designates the top of the reverberant decay range, 5 dB down the integration curve from the Ld marker. All of the level markers are user adjustable but positioning these three is pretty cut and dried. You should rarely find any need to touch them.
Lr2 = Level Reverberant 2. This marker designates the end point for the reverberant decay slope. If there is sufficient dynamic range – Lr2 should always be at least 10 dB above the noise floor – the preferred position is 30 dB down the reverse integration curve from Lr1. If not, 20 dB will do. This is one of the two markers that you may sometimes want to adjust by hand, the other being Ln (below).
Ln = Level of Noise. This is typically the most subjective of the five markers in terms of placement. Its time location determines the start point for the reverse time integration curve, which is the basis for positioning all of the other markers. Ideally, its time coordinate should roughly correspond to the saddle point in the impulse response. The magnitude coordinate for Ln is used to estimate the noise floor of the measurement and the Lr2 marker needs to be at least 10 dB above that.
Given a decent impulse response measurement, Smaart can usually place the Ld, Le, and Lr1 markers automatically with high confidence. The Lr2 marker position is also pretty straightforward, but its positioning is significantly influenced by the position of Ln, the potentially tricky one. The object is to place Ln at the saddle point of the IR, where the reverberant decay slope meets the noise floor, but this has always been a notoriously difficult thing to do algorithmically.
As a rule, Smaart does a pretty good job of placing the Ln marker most of the time. However, it may still benefit from a human touch in some cases – particularly if the dynamic range of the measurement is marginal or there are significant distortion artifacts from a swept sine measurement or any other prominent anomalies in the noise tail of the IR being analyzed.
When the level marker widgets for reverberation time are visible, a block of vital statistics also appears in the upper-right corner of the plot. These include the 60 dB reverberation and early decay times (RT60 and EDT) and the time and level differences between three pairs of markers. The Ld-Le level difference should always be 10 dB. Lr1-Lr2 should be either 20 or 30 dB – this number is convenient for checking your work if you end up adjusting Lr2 is by hand. The Ld-Ln delta is interesting also, as it gives you the dynamic range of the measurement. D/R stands for direct/reverberant ratio, an early-to-late energy ratio that gets its split time from the time coordinate of the Le marker.
Saving your work
If you adjust any of the Level marker positions by hand, you can save their positions to the IR .wave file header by clicking the Save button on the Data Bar. To import an existing decay marker CSV file for a .wav file in your IR mode data library, you can open the Trace Info and click the Import button.