Reverberation Time (RT60, T30, T20, T)

Prev Next

Reverberation Time (commonly referred to as T60, RT60, T30, T20 or simply T) is the time required for reverberant sound energy in a space to decay by 60 dB from an excited level. It is regarded as an important metric in the acoustics of not only musical performance spaces but also classrooms, auditoriums and cinemas, where it is used as a rough predictor of speech intelligibility.

Here are a few common ranges for expected (or ideal) reverberation time:

Church

2 - 10 sec

Concert Hall

1 - 2 sec

Office

0.5 - 1.1 sec

Classroom

0.4 - 0.6 sec

Reverse Time Integration

In Smaart, reverberation time is calculated from the reverse integration of an Impulse Response that has been filtered into octave bands. Conventionally, the 125 Hz to 4 kHz bands are evaluated. Reverse time integration is also called Schroeder integration, after Dr. Manfred Schroeder whose brainchild it was.

In theory, you could start at the end of the time record and work your way back to the beginning, tallying up the “squares” of each sample in the IR as you go. A common problem, however, is that the integration will flatten out when the reverberant decay slope runs into the IR’s noise floor. This can lead to overestimation of the reverberation time, particularly if the IR has limited Dynamic Range and/or a lengthy noise tail.

The most straightforward solution for this problem is to find the “saddle point”, or the point where the decay slope meets the noise floor. The saddle point can serve as a better integration starting point than an arbitrary point such as the end of the recording. However, the location of the saddle point in an IR is notoriously difficult to estimate automatically.

Smaart uses a proprietary algorithm for IR saddle point estimation that works well most of the time but is not completely foolproof. Therefore, it is always a good idea to check each band to ensure you agree with the choices the software makes – particularly if there are any large anomalies in the tail of the IR such as a prominent spike or any distortion products piled up at the end of the record as a byproduct of using a sweep Signal.

Reverse integration of the IR from the “saddle point” provides a largely accurate estimation of reverberant decay time.

Evaluation Ranges (EDT, T20, T30)

Because it is rarely possible to measure a full 60 dB of reverberant decay in acoustical systems, reverberation is typically evaluated over a smaller range. The starting point is always 5 dB down on the reverse integration curve from the point corresponding to the arrival of direct sound. The end point of the range is 30 dB down the curve from the starting point, provided that it is at least 10 dB above the noise floor – if not, a 20 dB range may be used. In either case, the measured decay time is extrapolated to the equivalent 60 dB decay time. In ISO 3382 parlance, these are referred to as T20 or T30. Early decay time (EDT) is conventionally measured from the arrival of direct sound to 10 dB down the integration curve. Like reverberation time, EDT is also normalized to 60 dB decay time.

T60 and Schroeder options at the bottom of the Control Bar.

You can calculate the reverberation time of a captured Impulse Response measurement in Smaart by clicking the RT60 button at the bottom of the Control Bar. You can also click the Schroeder button to make the Schroeder curve appear on the plot. Impulse Response recordings captured in .wav format can also be dragged into Smaart, if captured using other software.

Level Markers applied to an IR measurement

Notice the five level marker widgets shown on the plot in the figure above. These are turned on and off by the T60 button on the Control Bar. When multiple IR measurements are displayed, the level markers and reverse integration curve for the top trace (only) are shown.

To calculate reverberation time the level markers are conventionally positioned on the reverse integration curve as follows:

  • Ld = Level Direct. This marker is positioned on the reverse integration curve at the point corresponding to the arrival time of direct sound.

  • Le = Level Early (Decay). This marker is automatically positioned 10 dB down from the Ld marker on the reverse integration curve. The slope between Ld and Le is used to calculate EDT.

  • Lr1 = Level Reverberant 1. This marker designates the top of the reverberant decay range, 5 dB down the integration curve from the Ld marker. All of the level markers are user adjustable but positioning these three is pretty cut and dried. You should rarely find any need to touch them.

  • Lr2 = Level Reverberant 2. This marker designates the end point for the reverberant decay slope. If there is sufficient dynamic range – Lr2 should always be at least 10 dB above the noise floor – the preferred position is 30 dB down the reverse integration curve from Lr1. If not, 20 dB will do. This is one of the two markers that you may sometimes want to adjust by hand, the other being Ln (below).

  • Ln = Level of Noise. This is typically the most subjective of the five markers in terms of placement. Its time location determines the start point for the reverse time integration curve, which is the basis for positioning all of the other markers. Ideally, its time coordinate should roughly correspond to the saddle point in the impulse response. The magnitude coordinate for Ln is used to estimate the noise floor of the measurement and the Lr2 marker needs to be at least 10 dB above that.

Given a decent impulse response measurement, Smaart can usually place the Ld, Le, and Lr1 markers automatically with high confidence. The Lr2 marker position is also pretty straightforward, but its positioning is significantly influenced by the position of Ln, the potentially tricky one. The object is to place Ln at the saddle point of the IR, where the reverberant decay slope meets the noise floor, but this has always been a notoriously difficult thing to do algorithmically.

As a rule, Smaart does a pretty good job of placing the Ln marker most of the time. However, it may still benefit from a human touch in some cases – particularly if the dynamic range of the measurement is marginal or there are significant distortion artifacts from a swept sine measurement or any other prominent anomalies in the noise tail of the IR being analyzed.

When the level marker widgets for reverberation time are visible, a block of vital statistics also appears in the upper-right corner of the plot. These include the 60 dB reverberation and early decay times (RT60 and EDT) and the time and level differences between three pairs of markers. The Ld-Le level difference should always be 10 dB. Lr1-Lr2 should be either 20 or 30 dB – this number is convenient for checking your work if you end up adjusting Lr2 is by hand. The Ld-Ln delta is interesting also, as it gives you the dynamic range of the measurement. D/R stands for direct/reverberant ratio, an early-to-late energy ratio that gets its split time from the time coordinate of the Le marker.

Saving your work

If you adjust any of the Level marker positions by hand, you can save their positions to the IR .wave file header by clicking the Save button on the Data Bar. To import an existing decay marker CSV file for a .wav file in your IR mode data library, you can open the Trace Info and click the Import button.

Reporting Results for Reverberation Time

Ideally, reverberation time is measured from several locations throughout the room and the results from each measurement position should be averaged together, octave-band-by-octave-band to get an average decay time for each octave. Smaart doesn’t do that part for you, but the All Bands table does make it easy to get the data from each measurement into a spreadsheet.

Frequency Ranges

The standard evaluation range for reverberation time consists of six one-octave bands from 125 Hz 4 kHz. Average times for each octave band can be presented in a table or on a graph.

When presenting reverb times on a graph:

  • The x axis should be labeled with the IEC standard nominal octave band center frequencies (31.5, 63, 125, 250, 500, 1000, 2000, 4000, 8000, and 16000 Hz).

  • The y-axis should have an origin of 0 and be labeled in seconds.

  • It should be noted both in the table and on the graph whether T20 or T30 was used.

  • ISO 3382-1 specifies that if a graph is presented, it should be a line graph with a standardized aspect ratio of 2.5 cm per second and 1.5 cm per octave. (ISO 3382-2 isn’t so picky. It just says “a graph.”)

Reverberation times for the 125 and 250 Hz bands may be averaged together to get a T Low figure. The average of the 500 Hz and 1 kHz band is called T Mid. When a single number figure is given for reverberation time, it is assumed to be T Mid unless otherwise stated. Smaart calculates these values for you automatically and displays them in the All Bands Table.

Dividing T Low by T Mid gives you the Bass Ratio. Bass Ratio quantifies the “warmth” of sound in a venue and is a particularly important parameter for concert halls. The word “Bass” in this case refers to vocal or instrument bass registers and should not be confused with PA-type sub-bass frequencies. Acceptable values are dependent on context. For instance, a Bass Ratio of 1.1-1.25 would be regarded as good for fairly reverberant concert halls (RT60 greater than 1.8 seconds) but the upper figure could be increased to 1.45 for less reverberant spaces.

Similarly, preferred reverberation times vary according to room size and purpose and the type of program material presented. Shorter reverberation times (0.4 to 0.5 seconds for smaller rooms, 0.8 to 1.2 seconds for larger rooms) are preferred for auditoriums, classrooms, theaters and cinemas where speech intelligibility is a primary concern. Opera houses and mixed-use performance spaces where both speech intelligibility and musical appreciation are equally important, typically aim for the lower end of the 1.2 to 1.8 second range. Spaces intended for symphonic performances and organ music can range from about 1.8 seconds up to 3 seconds or more in very large halls.

Reverberation times that are roughly equal across all frequencies are generally preferable for most purposes. Exceptions include things like spaces wher choral, organ and romantic classical musical music are performed. In these cases, a reverberation time curve weighted more toward the lower frequencies may be preferred.

It is fairly normal for higher frequencies to decay faster than lower frequencies, but it can be problematic when times that are wildly different in neighboring octaves. In general, though, acoustical treatments and/or physical changes to the sound system are typically required to effectively address problems any problems you may find.