To view detailed settings for a Spectrum measurement, double-click its control block on the Control Bar or open the Measurement Config panel and either double-click its color tile in the Measurement Configuration table or select its name and click the info button below the table. Any of these actions will take you to a page with the settings below.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A12Z&se=2026-11-18T17%3A43%3A12Z&sr=b&sp=r&sig=v%2B5JMPockUHwrxDnfZGDs69ndBVhRy%2Bq0ThdCyKN3G4%3D)
Spectrum Measurement Engine Settings flyup menu.
Measurement Settings
The Name field under Measurement Settings sets the measurement name. If you edit the measurement name, be sure to press the [Enter] key to set the change when you are finished.
The Delay field sets the signal delay for the measurement in milliseconds. For spectrum measurements this will normally be 0.00, but there may be special cases you would want to delay a signal for display purposes.
FFT size (in samples) determines the Time Constant and frequency resolution of the frequency Domain displays. Increasing FFT size provides finer frequency resolution, enabling you to distinguish features more closely spaced in frequency, but does so at the expense of time resolution, the ability to resolve features transient of a signal that are closely spaced in time. In general, the default setting of 16K points is a pretty good trade-off between the two that works well for most applications, given a sampling rate of 44.1k or 48k samples per second.
Averaging Depth specifies the length of time over which individual measurements are averaged to smooth and stabilize the traces or bar graphs on the screen. Bigger numbers give you longer averaging times.
The FFT and Averaging Depth settings normally follow the global settings for spectrum measurements set in the Spectrum Measurement Settings dialog. You can however, set either or both of these setting independently for an individual measurement engine by un-checking its Use Global check box and selecting a new setting from the drop-list control.
Display Settings
Color has a clickable tile that, when clicked, opens a color picker dialog to change the display color for the measurement. When committed, these changes apply to all linked copies of the measurement with the same name on other tabs and windows.
Plot sets the preferred graph assignment for the measurement. It is ignored when only one graph of a given type is displayed. If you bring up a second graph of the same type in the same tab, measurements with a Plot setting of 1 (the default setting) will stay with the first instance of the graph and any measurements with a setting of 2 will move to the second.
Weighting applies a weighting curve to the spectrum measurement to reshape its spectrum, subtracting from the level values at some frequencies and perhaps adding to them at others. Weighting in the frequency domain is analogous to filtering the in the time domain. Common weighting curves include A and C weighting used for SPL and Leq measurements. (Suite and RT only)
If the Follow Plot checkbox is checked for Weighting this setting follows changes to the global weighting setting for spectrum measurements set in the Spectrum Graph Settings dialog and/or via the on-graph weighting control if applicable. Un-checking this box enables you to set weighting specifically for the individual measurement.
Input Settings
Input settings for spectrum measurements consist of a single input Device and Channel selection.
Device - The I-O device (or driver).
Channel - The specific input from said I-O device that is being used.