Frequency-Domain “time windowing” (FTW) is a complex linear smoothing technique performed in the frequency domain that is mathematically equivalent to applying a tapered window function to the Impulse Response in the time domain and transforming the result with a zero-padded FFT. Since the bandwidth of the smoothing kernel is linear, the effects of FTW are most noticeable at lower frequencies. Because complex data includes both the time (phase) and magnitude response of the system, FTW smoothing affects both traces simultaneously, without separate controls like you'd see with fractional octave smoothing.
For some general context, we have an article on Smoothing available here.
FTW is a global function applied to all live and captured Transfer Function measurements that use Complex Magnitude averaging (only). Enabling FTW forces the global magnitude averaging selection for live transfer function measurements to Complex. However, live measurements do not use the global setting and are unaffected by FTW if their magnitude averaging selection is Polar. Stored data traces captured using polar magnitude averaging are also unaffected. When FTW is turned on, a vertical red line appears on transfer function Magnitude and Phase graphs denoting the low-frequency cutoff for the equivalent Time Window. Because FTW limits the effective window size of the equivalent impulse response, data at frequencies below the cutoff frequency cannot be reliably resolved and should not be considered trustworthy.
Impulse Response time-windowing is commonly used to 'clean up' measurements by eliminating reflections or later arriving energy from other sources. When a time-windowed IR is transformed into the frequency domain, some later-arriving noise and comb filter-causing reflections are "windowed" out of the frequency response. FTW Smoothing in Smaart emulates the frequency-domain resultant of IR time-windowing the IR in the time domain without requiring transforms back and forth between domains.
Enabling FTW
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A00Z&se=2026-11-18T17%3A39%3A00Z&sr=b&sp=r&sig=%2Fk%2BlO%2Fgy%2B4CeUpK2GzIdLBaCEuzShBtbXFlzxcOd3CY%3D)
FTW smoothing must first be enabled in
Options > Preferences > Advanced
via the "Frequency Time Windowing (FTW)" checkbox.
FTW Smoothing is set in terms of equivalent nominal half-window length. Once enabled, two additional controls appear below the averaging control for transfer function measurements:
A checkbox to turn FTW on and a text field to set the nominal time window size in milliseconds.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A00Z&se=2026-11-18T17%3A39%3A00Z&sr=b&sp=r&sig=g7pUJx%2B62Mtfs2p1QXPUXqF7msJYK7LnAUY4kyaSsjI%3D)
Activating FTW will change the global Magnitude Averaging (Mag Avg Type) setting for TF measurements to "Complex". Additionally, it will smooth any measurement set to "Complex" locally along with any captured data traces that were captured while set to "Complex".
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A00Z&se=2026-11-18T17%3A39%3A00Z&sr=b&sp=r&sig=zfn1tk2xC26tVLlqrlMgAgh4rGUYQnFCHp9RkH1c6wI%3D)
Setting the FTW Smoothing Value
FTW Smoothing is set in terms of nominal half-window length in milliseconds. The maximum half-window size is one half of the FFT Time Constant (TC = FFT Size / Sample Rate). It's generally more practical to stay below 25-30% of the FFT time constant, however.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A24%3A00Z&se=2026-11-18T17%3A39%3A00Z&sr=b&sp=r&sig=Y2z5%2FGeARR4FcopQztyxxBRuczJ2BiekFMnOpxGQpyg%3D)
When FTW is turned on, a vertical red line appears on transfer function magnitude and phase graphs indicating this threshold frequency, based on the current nominal time window setting.
Since FTW smoothing limits the effective time window of the measurement, the effective frequency resolution of the FTW-smoothed measurement depends on the nominal time window. For example, a 20ms FTW window size has an effective frequency resolution of 100Hz, regardless of FFT size. Data at frequencies below that point should be ignored, as they are below the first valid data point (100Hz). Smaart will indicate the lowest point for accurate frequency resolution via a vertical red line on each plot.