SPL Statistics Bar

Prev Next

Below the SPL mode Detail pane, across the bottom of the main program window, is the Statistics Bar. This bar displays a statistical analysis of the data appearing within the selected time range for the top metric in the z order. For most metrics, the Statistics Bar displays Max, L10, L50, and L90 data for the selected time range.

Time Range Statistics Bar.

  • Max is the highest value logged for the metric within the selected time range.

  • L10 is the level that was exceeded by 10% of the data points within the selected time range.

  • L50 is the level that was exceeded by 50% of the data points within the selected time range. In other words, the median level.

  • L90 is the level that was exceeded by 90% of the data points and is sometimes regarded as a useful indicator of background or ambient noise levels.

Exposure Statistics

When Exposure O or Exposure N data is the selected metric (on top of the z order), the statistics bar instead changes to display Max, Min and Delta.

Exposure Statistics.

  • Max is the highest exposure value logged within the selected time range as a percentage.

  • Min is the lowest exposure value logged within the selected time range as a percentage.

  • Delta, the difference between Max and Min, is the sound exposure dose accumulated in the selected time range as a percentage.