Below the SPL mode Detail pane, across the bottom of the main program window, is the Statistics Bar. This bar displays a statistical analysis of the data appearing within the selected time range for the top metric in the z order. For most metrics, the Statistics Bar displays Max, L10, L50, and L90 data for the selected time range.

Time Range Statistics Bar.
Max is the highest value logged for the metric within the selected time range.
L10 is the level that was exceeded by 10% of the data points within the selected time range.
L50 is the level that was exceeded by 50% of the data points within the selected time range. In other words, the median level.
L90 is the level that was exceeded by 90% of the data points and is sometimes regarded as a useful indicator of background or ambient noise levels.
Exposure Statistics
When Exposure O or Exposure N data is the selected metric (on top of the z order), the statistics bar instead changes to display Max, Min and Delta.

Exposure Statistics.
Max is the highest exposure value logged within the selected time range as a percentage.
Min is the lowest exposure value logged within the selected time range as a percentage.
Delta, the difference between Max and Min, is the sound exposure dose accumulated in the selected time range as a percentage.