General (Preferences)

Prev Next

The General tab of the Preferences dialog contains settings that apply to Smaart’s appearance and behavior and is accessible by either navigating to Options > Preferences > General or by using the [Alt/Option] + [O] hot key. Below and to the left is the full version of this dialog as seen in Smaart Suite, LE, and RT. Smaart SPL contains a similar version with fewer options, and is shown on the right. All options below will refer specifically to the Smaart Suite/RT/LE version of this dialog unless otherwise noted.

The General page of the Preferences dialog as seen in Smaart Suite, RT, and LE (left)

and as seen in Smaart SPL (right).

International

The selection in this section determines what types of distance and temperature units are used to calculate the Speed of Sound in air and approximate distance equivalents for delay times and time coordinates on time-Domain plots.

  • Measurement System selects whether the speed of sound and distance are displayed in feet (Imperial) or meters (Metric). Similarly, this determines whether temperatures are displayed using Fahrenheit or Celsius , respectively.

  • Session Folder Naming determines whether Session Folders are named using year/month/day or month/day/year. (Also Available in Smaart SPL)

  • Use Comma Decimal in Exported Text Files, when enabled, uses the comma character [ , ] as the decimal mark instead of an ASCII period [ . ] to separate the whole number parts of real numbers from the fractional parts in log files. This change affects only data written to log files; Numeric readouts in the GUI will still use the period as decimal mark.

Speed of Sound

The settings in this section determine the speed of sound that Smaart uses for calculating equivalent distances for time coordinates. It can also serve as a handy speed of sound calculator any time you need to know the speed of sound for a given air temperature.

At elevations where humans would be comfortable breathing, the speed of sound is mainly a function of temperature, and so the two input fields in this section are linked. Changing the temperature setting automatically recalculates the corresponding speed of sound and vice versa. The units used (feet/meters and degrees Fahrenheit/Celsius) are determined by the selection in the International section above.

Trace Behavior

  • Movement sets the move increment for the Front Trace Up and Front Trace Down commands (hot key [Ctrl/Cmd] + [ ↑ or ↓ ]). These commands move the selected plot’s front trace up or down by the number of decibels (dB) defined here. This field accepts decimal values if finer control is needed.

  • Color provides three choices to determine a newly captured trace:

    • Random – captured traces will be assigned a "random" color, based on the previously-observed behavior.

    • Based on Engine Color – captured traces will instead be assigned a color similar to the measurement engine's color.

    • Same as Engine Color – captured traces will instead be assigned the measurement engine's exact color.

  • Location determines whether traces appear in front of or behind the plot grid. (Available in Smaart SPL)

  • Session Folder Creation determines whether the Create Session Folder option will create a session folder for the current mode or for every mode simultaneously. (Available in Smaart SPL)

Online Behavior

Automatically Check for Updates determines whether Smaart automatically checks to see if a newer version of the software is available on startup (so long as your computer is connected to the internet). You always have the option of whether or not to install the update if a newer version is found. Deselecting this box bypasses this procedure, but you can still check for updates manually by selecting Check for Updates from the File menu.

Signal Generator

The Gain Increment dropdown will adjust the precision at which the signal generator can be adjusted. When set to 1.0 dB, whole numbers are used to set signal level and the signal generator + and – buttons will change the level in 1dB increments. When set to .5 dB, each Decibel of change will have two steps, and the + and – buttons adjust the level in .5 dB increments.

Fly-Out Window Behavior

Automatically Collapse when Clicking Outside – when selected, clicking outside of any "fly-out" or "fly-up" component will automatically close it.

Clock

  • 24 Hour Clock changes the clock display in Smaart from a 12-hour clock to 24-hour. The clock display replaces the numeric signal level/sound level meter in the upper right corner of Smaart windows when you press the [K] key on your keyboard.

  • Show Date in Clock toggles whether the date is shown in the clock underneath the time. When the date is not shown, the time display is larger.