The Transfer Function page of the Graph Settings dialog is devoted primarily to display settings for transfer function (Magnitude, Phase and Live IR) plots. It is accessible by selecting Options > Graph Settings > Transfer Function or via the [Alt/Option] + [T] hot key, or by clicking the settings button (
) in the lower-right corner of any transfer function graph in any main window graph area.
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A23%3A57Z&se=2026-11-18T17%3A41%3A57Z&sr=b&sp=r&sig=S6m9m6xTxLIQ87Ez%2B3cDM6jbsaTYjud3I3E22%2F%2Flmks%3D)
Options > Graph Settings > Transfer Function.
General Settings
Frequency Scale – determines the type of frequency scaling and grid ruling used for transfer function Magnitude and Phase displays. Actually, there are just two scaling options: linear (Lin) and logarithmic. The other choices in this list are grid-ruling options for log-scaled frequency.
Decade plots Magnitude and Phase graphs with logarithmic frequency scaling and decade (base 10) vertical grid ruling.
Octave plots Magnitude and Phase graphs with logarithmic frequency scaling and vertical grid lines spaced at one-octave intervals.
1/3 Octave plots Magnitude and Phase graphs with logarithmic frequency scaling and vertical grid lines spaced at 1/3-octave intervals.
Lin plots Magnitude and Phase graphs with linear frequency scaling and linearly-spaced vertical grid ruling.
Display Live IR – when this box is checked the Live IR graph is displayed whenever either of the two frequency-domain transfer function graphs (Magnitude or Phase) is visible.
Line Thickness – controls set the line thickness for all line charts in Smaart, including Transfer Function (Magnitude, Phase, Live IR) RTA line charts and Impulse Response mode time- and frequency-domain displays.
Foreground Trace – sets the line thickness in pixels for the data trace at the top of the z axis (the frontmost trace) on all line charts.
Background Trace – sets the line thickness in pixels for all data traces other than the top trace when multiple traces are displayed on any line chart.
The Weighting control assigns a global weighting curve to transfer function magnitude graphs. Smaart has built-in curves for A and C weighting curves used in SPL and Leq measurements with normal and inverted versions of each. You can also create your own weighting curves from transfer function data traces or by importing ASCII text files. See Weighting Curves for more about custom weighting curves.
When Weighting is set to something other than None, the state of the Display Weighting control determines whether an interactive drop-list control appears on transfer function magnitude graphs. This allows you to change the weighting setting directly from the graph in the main window. Note that the in-plot control is disabled when Display Weighting is un-checked or if Weighting is set to None.
Link Global Plot Smoothing – when this box is checked, the smoothing controls for all frequency domain transfer function graphs of the same type are linked, so that changing the smoothing setting on any one graph automatically changes the setting for all like graphs in all tabs and windows to match.
Link Phase & Mag Smoothing – when this box is checked, the smoothing controls for all phase and magnitude graphs are linked, so that changing the smoothing setting on any one graph automatically changes the smoothing setting for all graphs of both types in all tabs and windows to match.
Link Plot Zoom – when enabled, all plots of the same measurement type with a common axis share zoom. For example, rubber-band zoom in the a Magnitude plot also effects the Phase plot. This was the default behavior before v9.5, but now it is disabled by default (meaning all plots have independent zooms). Links between the IR navigation plot and other IR plots are excluded from this option and are always enabled.
Plot Proportional Graphs – sets the vertical height of the Live IR graph to occupy an equal proportion of the graph area relative to other graph panes (rather than a smaller, fixed-height graph pane).
Plot Instantaneous Response – displays un-averaged frequency data for the front trace from each new incoming measurement update, along with the (typically averaged) standard trace data. When enabled, frequency data points for the instantaneous response data will appear on the graph as unconnected dots, rather than a line trace.
Allow unsmoothed data – adds “No Smoothing” as an option in the smoothing drop-list controls on transfer function phase and magnitude graphs when checked.
Magnitude
Magnitude Range (dB) – sets the default Decibel range for the transfer function Magnitude display.
Track Peak – causes Smaart to track and display the magnitude and frequency of the data point with the highest magnitude in the front trace on the transfer function Magnitude plot when enabled.
Y-Grid Interval (dB) – sets the grid ruling interval for transfer function Magnitude graphs.
Y-Scroll Increment (dB) – sets the increment for keyboard scrolling in the transfer function magnitude display. When a transfer function Magnitude display is selected in the plot area, each press of the up/down arrow keys ([ ↑ ] or [ ↓ ]) will scroll the plot up or down by the number of decibels specified in this field.
Y-Zoom Increment (dB) – sets the increment used for keyboard zoom on the y axis of the Magnitude graph. When a transfer function magnitude display is selected in the plot area, pressing the [+/=] or [−] keys will increase or decrease the vertical scale of the graph by the number of decibels specified here.
Phase
Unwrap Phase – “unwraps” the phase display when selected, by looking for “wrap” points where the phase trace crosses the +/− 180° boundary, then “splices” the trace at these wrap points to give you a more continuous view of phase response. Keep in mind however, that the actual phase data is always in the range +/− 180°, meaning the wrapped display has to rely on some assumptions that may be questionable in some cases. This type of display tends not to work very well if the incoming measurement data has a poor signal-to-noise ratio. When Unwrap Phase is selected, the notation “Unwrap Center” appears on phase charts in the main Smaart window with a frequency in Hz. Clicking on the Unwrap Center frequency with your mouse makes it editable. This frequency should generally be set to the center of an SUT pass-band being analyzed or other frequency range of interest.
(Unwrapped Phase) Range – sets the minimum and maximum values (in degrees) for the unwrapped phase display. You can also adjust the range of the both unwrapped phase and group delay graphs using the [+]/[−] keys on your keyboard or by rubber-band zooming with your mouse or other pointing device.
Phase as Group Delay – when selected, converts phase angles between adjacent frequencies in the phase display to relative time values (in milliseconds). A value of zero milliseconds for a given data point means the reference and measurement signals are arriving at exactly the same time at that frequency. Positive time values indicate that the measurement signal is arriving later than the reference signal at those frequencies. Negative time values indicate that the measurement signal is arriving before the reference signal. Be aware that time values for frequencies where the measurement is noisy may be questionable.
Coherence
Show Coherence – displays the coherence function by frequency for the trace at the top of the z-axis on the transfer function Magnitude display. The coherence trace is normally shown in the upper half of the Magnitude display between 0 dB and the top of the graph. Please note that since coherence is calculated by comparing averaged and un-averaged transfer function data, the coherence trace is not displayed when averaging is set to None.
1/4 Height Coherence – compresses the coherence display into the topmost 1/4 of the transfer function Magnitude graph. When this box is un-checked, the upper half of the magnitude graph is used. Select this option if you want more unobstructed graph area for magnitude traces when displaying coherence.
Squared Coh – displays coherence data as magnitude squared coherence when selected, which can make coherence traces easier to read in some cases.
Coh Blanking Threshold % – sets the minimum allowable coherence value for transfer function Magnitude and Phase displays. Frequency data points with coherence values that fall below the value specified here will not be displayed. This setting can also be changed by moving the arrowhead-shaped widget that appears on the upper right edge of transfer function Magnitude graphs in the main window.
Line Thickness Follows Foreground – when enabled, causes the coherence trace's line thickness to match the Foreground Line Thickness setting. When disabled, the option below will become available and allow you to choose a separate line thickness value for the coherence trace.