A Smaart SPL rig consists of the following components:
A license of Smaart with the SPL feature set (Smaart Suite, Smaart SPL)
A computer that meets Smaart’s minimum system requirements.
Or (instead of microphone, interface, and calibrator)
Microphones
Unlike most general measurement applications, SPL measurement at concert levels can be more demanding on the hardware used. For this reason, SPL measurement requires additional consideration from the general measurement hardware guidelines.
Maximum SPL Rating
Many measurement microphones cannot physically handle the high Peak levels encountered in a typically concert-level measurement situation. Overloads can be problematic, as an overload event will result in all averaging buffers being flushed and the invalidation of large periods of log data.
We recommend a measurement microphone with a Max SPL rating of at least 135 dB SPL, preferably 140 dB SPL. This may seem excessive, but it is not. A typical musical program material will have instantaneous Peak levels 30 to 35 dB higher than average A-weighted levels. For example, if a show hovers around 99 dB SPL A Slow, you can expect Peak values in the mid 130’s.
Sensitivity
Additionally, an SPL measurement microphone should have relatively low sensitivity. At high SPL, some sensitive microphones produce very high voltages that can overload the connected preamp and converter.
For example, a Gen 1 Earthworks M30 has a sensitivity of about 34 mV/PA. At 140 dB SPL, it will pass a voltage of 6.8Vrms (+19 dBu) to the interface, and many preamps will be overloaded. By contrast, an iSEMcon EMX-7150 has a sensitivity of 6 mV/PA. At 140 dB SPL, it will pass a voltage of 1.2Vrms (+4 dBu) to the interface, which most preamps can comfortably accommodate at minimum gain.
Interfaces
While we’re on the topic of voltage, let’s talk about audio interface choices. While we are not concerned about the performance of modern audio interfaces, higher voltage ratings can provide more headroom for your SPL measurements.
Headroom Calculator
SPL Calibrators
In addition, a sound level calibrator is necessary for accurate SPL measurement. The calibrator produces a known acoustic pressure at the mic, which allows the software to associate between that acoustic level and the resulting digital value.
Take a look at our calibration procedure article for information on how to use a calibrator.
Class Compliance
Class Compliant means that the measurement rig – and all its components – have been individually lab-certified to meet all the requirements of the applicable standards. This doesn’t mean the measurement is any more accurate, but it does mean that the SPL log data collected by the system can rise to a legal standard of evidence. Systems like 10EaZy come pre-calibrated and tested from the factory, and are tamper proof, so you know the measurement data can be trusted.
Class Compliant hardware becomes important if you need to prove in court that your levels were not in violation of a noise ordinance, workplace noise regulation, or other legal requirement.
Dedicated Hardware
It is important to mention that there are dedicated, tamper-proof hardware systems for SPL measurement. Smaart v9 integrates with 10 EaZy