Sound Level Measurements

Prev Next

Smaart® is capable of measuring Full Scale and Sound Pressure Level (SPL) using a variety of metering options. Over the last decade or so of development, SPL functionality in Smaart has developed from a single SPL meter in the main user interface (which we still support), to a fully featured SPL Mode entirely dedicated to be a comprehensive solution for SPL monitoring, logging, and reporting. SPL Mode contains various history plots, fully customizable metering metrics, remote-viewing capabilities, alarms and even notes, customizable 'traffic light' metering color options, logging and report generation, as well as class 1 or 2 capability with the appropriate hardware.

SPL Mode is found in Smaart Suite and Smaart SPL. Smaart LE and RT offer the in-plot, view-only, SPL meter - which long time users will recognize from the v7 and Di interfaces. While improved upon some by adding the ability to apply meter coloring, commonly called 'traffic lights', the SPL functionality in RT and LE is otherwise limited to a single display that does not offer logging, alarms, or any of the more advanced functionality of SPL Mode.

Full Scale (dBFS)

By default Smaart will display all level values as dBFS. These negative values indicate the digital level seen by the input device you are using.

dBFS vs Full Scale

There exist two competing references for decibels in digital audio signals. Once convention references dBFS to the largest possible Amplitude value in a digital system, such that 0 dBFS denotes the maximum possible digital amplitude value. We refer to this as “normalized Full Scale.” The second convention, preferred by the Audio Engineering Society (AES), references 0 dBFS to the RMS value of a full-scale peak-to-peak sine wave (i.e. 0.7071 normalized Full Scale, rather than 1.0). We will call this “AES Full Scale.” In Smaart, Full Scale Decibel values are always referenced to normalized full scale, meaning that the RMS level of a full-scale digital sine wave is -3.01 dBFS.

Sound Pressure Level

Sound Pressure Level is a measure of the RMS average pressure deviation from still air over some period, integrated by an exponential “time-weighting” function. SPL is stated in decibels, referenced to 20 micro-Pascals (μPa) – the approximate threshold of audibility for humans – such that 94 dB SPL ≈ 1 Pascal.

There are a variety of SPL Metrics used, determined by their Time integration and Frequency weighting.

Time Integrations

Peak Level

The “Peak” measurement always shows the maximum instantaneous level reached within a measurement interval. While technically not “SPL” due to the lack of an RMS average in its calculation, it is still useful for measuring high level impulses and is commonly used as a secondary “SPL” limit at live events.

Fast & Slow Time Weighting

The most common way to see SPL is using Fast and Slow “time-weighting.” These integrations are implemented as first order low pass filters with the time constants of 1/8th of a second for fast and one second for slow. The video below displays peak, fast, and slow metrics in Smaart, and how quickly they respond to changes in level. Despite being given the name of “Slow,” SPL Slow is actually quite fast, which can lead to problems interpreting levels over time. The video This is where Equivalent Continuous Level (Leq) comes into play.

Equivalent Continuous Level (Leq)

Equivalent sound level (Leq) is a way of representing sound levels that vary over time as a single figure, as though the same amount of energy had been received over the same amount of time at a constant level. In other words, Leq is a measurement of the total sound energy over a period of time, presented as a single dB value. It is widely used for assessment of environmental noise in applications ranging from airports to constructions sites to rock concerts, and can answer the question “what is the equivalent steady-state level over the same amount of time?”

Leq is stated in a notational form that includes the frequency weighting used and the period over which the measurement was taken. For example, 85 dB LAeq 10 means 85 dB equivalent continuous A-weighted sound level measured over a period of 10 minutes.

For a more in depth look at time integrations, take a look at the Time Weighting & Time Averaging article.

Frequency Weighting

Smaart offers multiple options for frequency weighting, including A, C, Z (unweighted), and octave banded filters.

Traditionally, sound level measurements have been calculated with A or C frequency weighting. As a general rule of thumb (but not law) A weighting is used for measuring frequencies that tend to cause hearing damage, while C is a better indication of nuisance noise and neighbor complaints.

Octave Banding

Smaart Suite and Smaart SPL also offer the ability to measure sound levels in octave wide bands, on center frequencies from 16Hz through 16kHz. This can be useful for helping to study how sound level energy is distributed over frequency.

Sound Exposure

Smaart can also measure Sound Exposure, using the Exposure N and Exposure O dosimeter metrics. Exposure N calculates exposure based on limits recommended by the U.S. National Institute for Occupational Safety and Health (NIOSH), while Exposure O uses the U.S. Occupational Safety and Health Administration (OSHA) guidelines. Displayed values indicate exposure dosage as a percentage, with 100% constituting the full allowable dose for one workday.

Hardware Considerations & Calibration

Measuring SPL has additional specific hardware requirements, which have been detailed in the Selecting Hardware for SPL Measurement article. Additionally, Smaart requires a calibration procedure in order to relate acoustic levels to the dBFS values that Smaart calculates by default.

Standards Compliance.

The DSP routines in Smaart that calculate sound level metrics in Smaart are fully compliant with applicable standards for SLMs and dosimeters. When used with suitable hardware (microphone, preamp, input device…) and properly calibrated, Smaart can provide sound level measurement results as accurate as a dedicated sound level metering instruments with one very important caveat. We cannot certify compliance with applicable standards for SLMs and dosimeters because the test regime for certification requires testing the complete instrument. There is no process for certifying the performance of the Smaart software alone, without your specific Smaart measurement system hardware.

It is possible to assemble a fully standard-compliant Smaart measurement setup and obtain a certificate of calibration as a Class 1 or Class 2 SLM from an accredited test lab for that specific setup, but it is expensive and time-consuming and may require upgraded hardware, in addition to the cost of lab testing. Smaart users may therefore want to consider other metering options instead of, or in addition to using Smaart in applications where lab-certified instrumentation is strictly required.