The Quick Compare feature is intended as a quick, temporary way to subtract one Transfer Function measurement from another. It is functionally equivalent to exporting a transfer function trace as a weighting curve, then applying the resulting inverse weighting curve to all live transfer function measurements. The difference is that there are fewer steps involved and nothing to clean up when you’re done (if you don’t want to keep the weighting curve for posterity).
Capture Quick Compare
To do a quick compare you first need to save an existing measurement into memory to use as a reference. The reference can be any live transfer function measurement or trace data file. To capture the quick compare reference curve, make sure that the active graph is a transfer function Magnitude or Phase plot and the trace that you want to reference is the top trace on the graph. If you don’t see its name showing in the upper right corner of the graph, click the control block for the measurement on the Control Bar or the trace name on the Data Bar for the trace that you want to use or press the [Z] key on your keyboard repeatedly until it comes to the front, then press [Alt/Option] + [Q] or select Capture Quick Compare in the Command menu to copy the trace into memory.
Toggle Quick Compare
When you have captured the quick compare reference curve, press the [Q] key on your keyboard or select Toggle Quick Compare from the Command menu to subtract it from all live measurements that are running. To turn quick compare off press the [Q] key or select Toggle Quick Compare from the Command menu again. To replace the reference, simply repeat the Capture Quick Compare procedure.