The File > Import > Trace Data File command (keyboard shortcut: [Ctrl/Cmd] + [L]) imports Smaart data files from other locations into your data library – the location on your hard drive (or other storage device) that you have designated as the storage location for data files in your current session. Smaart Suite, RT, and LE can read Spectrum (.srf) and Transfer Function (.trf) data files from Smaart v7 or later. Smaart Suite is also able to read Impulse Response measurement data stored in .wav or .aiff audio files. Smaart Suite and Smaart SPL are able to read SPL logs stored as .txt files, as well.
To import a trace into your data library, select File > Import > Trace Data File from the file menu or press [Ctrl/Cmd] + [L] on your keyboard. Either of these actions opens the Load Reference File dialog, where you can navigate to the location of the data that you want to import, select the file(s) that you want to import, and then click the Open button. If you are loading .ref files they will be converted to the appropriate native file type (.srf or .trf) automatically.
Notice that the dialog that appears will only show you native data files that match the active graph selection in the active Smaart window. In real-time mode, if the active graph is a transfer function (Magnitude, Phase or Live IR) graph, you will see only .trf files. If the active graph is an RTA or Spectrograph, you will see only .srf files. In IR mode, Smaart will show you only .wav or .aiff files. Note that legacy .ref files from older versions of Smaart can contain either spectrum or transfer function data. You cannot tell what type of data they contain by looking at the file name, and so if you select a .ref file for import and nothing happens, try switching the graph type.
Keep in mind that spectrum files have absolute dB levels associated with their data points, so there might be cases where the import is successful but the data is off the screen – for example, if your RTA display is calibrated to SPL and the imported file was captured with Full Scale calibration. In that case however, you would still see the trace name and its icon added to the graph legend. If you make the imported trace the front trace and run your mouse cursor across the graph, the cursor readout can tell you where to look for the data.
Note: Smaart cannot open reference group (.rgp) files from older versions of Smaart, Smaart Pro, or SmaartLive. If you have data stored in an .rgp file that you want to import into Smaart v9, you will need to open it in a compatible version of SmaartLive or Smaart Pro and save the traces that you want to open in Smaart v9 as trace (.srf or .trf) files.