9.7 Beta Overview
Save for any potential patches, 9.7 will be the final evolution of the Smaart v9 platform. Just as 9.6 was centered on SPL mode, 9.7 will be largely focused on expanding and refining Impulse Response mode functionality (along with some general optimizations and fixes). 9.7B1 includes the first few changes including a brand new IR mode Timer, a new IR mode grid line interval preference, and the long-requested ability to resize the All Bands table. General improvements include the addition of multi-trace recapture and the ability to copy and paste both IP address and host name from the API Preferences window.
New Features in 9.7 beta1:
New in-plot SPL calculations based on running spectrum measurements
New Multi-Recapture functionality
Added SPL information to spectrum metadata
Added the ability to recapture multiple traces simultaneously
Added IR Mode Timer
Full Release Notes:
Added IR mode grid line interval setting
Added advanced option to average SPL for spectrum measurements with calibrated contributors and view in RTA plot
Added SPL capture for spectrum traces when spectrum SPL was calculated
Added IR Mode Timer
Added ability to resize the All Bands Table
Added option to capture SPL values for a spectrum trace
Added ability to copy and paste IP address from API Preferences
Added ability to recapture multiple traces at once
Improved All Bands table exporting
Updated SPL Calibration progress bar to match new SPL Compensation progress bar
Updated error message when IR measurements were started without device connected
Updated error messages for overloaded or digital black IR measurements
Updated Measurement Pause Button Behavior
Updated add Plot behavior regarding plot type
Updated view flyup and added plot proportional graphs checkbox
Updated Sync Ld behavior and renamed to Sync Peak
Restored behavior of [Cmd/Ctrl] + [Right Click] to unlock a locked cursor
Removed D/R calculation from IR mode
Removed Fallback font choice due to JUCE update
Fixed a bug where transfer function engines could be run using disabled inputs
Fixed potential bug with signal generator
Fixed a bug with editing of reference channel input after changing IO device for transfer function measurements
Fixed a bug where unwrap phase would disable phase changes from PTR offset
Fixed a bug where engine selection in IR mode did not match real time mode
Fixed a bug where measurement settings did not reflect live average configuration
Fixed a bug with ETC calculation
Fixed a bug with invalid data in FTW and LIFFT
Fixed a bug with LIFFT calculation
Fixed a bug with recapture trace
Various bug fixes regarding multi spectrum view
Fixed a crash when dragging TF engines into the control bar in the client window