--- title: "Octave & Fractional-Octave Banding (Spectrum Measurements)" slug: "octave-fractional-octave-banding-spectrum-measurements" updated: 2026-05-12T17:46:06Z published: 2026-05-12T17:46:06Z canonical: "doc360.rationalacoustics.com/octave-fractional-octave-banding-spectrum-measurements" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Octave & Fractional-Octave Banding (Spectrum Measurements) Octave and fractional octave banded spectra are another way of reconciling how we hear with what we see on an analyzer screen. On a banded RTA or Spectrograph display, each fractional octave band represents the summation of the power at all frequencies that fall within that band. That’s why a banded measurement of Pink Noise looks flat on a banded display, but if you look at the linearly spaced FFT data, you see a Signal that rolls off at 3 dB per octave or 10 dB per decade. Each individual FFT bin contains less and less energy as you ascend in frequency but each octave band is comprised of twice as many frequencies, so all the bands add up to an equal number of decibels (given a perfectly pink signal). If you look at a White Noise signal, which has equal energy at all frequencies (nominally at least), you would see that it appears flat on an un-banded linear or logarithmic Spectrum display, but slopes upward at 3 dB per octave on a banded display. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(223).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A18Z&se=2026-11-18T18%3A42%3A18Z&sr=b&sp=r&sig=EPjU7ggSFRzhroLQZAv16vVMxELTpuTaYy1WWH8Y4Z8%3D) *Fractional-octave banding vs FFT data on a logarithmic frequency scale. The lighter green bars show a 1/12-octave banded RTA measurement of pink noise. The darker green line trace is a narrowband (un-banded) view of the same data on a logarithmic frequency scale.* Banded spectrum displays are useful for several reasons. Notably, they can be used in conjunction with pink noise to make a poor man’s measurement of the Magnitude portion (only) of the frequency response of a device or system. A single channel spectrum measurement can’t tell you anything about timing or Phase relationships, both of which are important factors in how a system actually sounds, but it could be better than nothing in a pinch, or perhaps as a quick maintenance check of a system that has already been aligned. Another way that banding is useful is just as a way of smoothing spectral data. By summing FFT multiple bins into each band, you immediately start to get a display that is smoother and more stable than watching the individual bins jumping around. There is a psychoacoustic dimension to banding as well. Pink noise seems to be ubiquitous in nature and in complex systems of all kinds, so perhaps it is not surprising that the long-term average spectra for all kinds of music, across a wide range of genres and cultures, tends to be similar to that of pink noise. Banded spectrum displays may therefore tend to be a natural and intuitive way of looking at the spectral content of music and other signals for that reason. The Real-Time Analyzer (RTA) enables you to look at the frequency content of signals moment-by-moment in real time. The RTA is a graph of the energy in an incoming signal, broken down by frequency or frequency ranges, with frequency (in Hertz) on the x axis and magnitude (energy) on the y axis in decibels (dB) A three-dimensional data plot, displayed in two dimensions with color representing the third dimension (or z-axis). The spectrograph is a topographical representation of the once-common waterfall display. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. A random (or pseudorandom) signal in which, over a given averaging period, each frequency has equal energy. White noise is a common test signal in electronics. It is seldom used in testing systems that include loudspeakers because it has so much high-frequency energy that it can easily damage HF components of the system, and human hearing as well. The frequency content of a given signal. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency.