--- title: "Import ASCII" slug: "import-to-ascii" status: "new" updated: 2026-10-22T19:35:29Z published: 2026-10-22T19:35:29Z canonical: "doc360.rationalacoustics.com/import-to-ascii" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Import ASCII In addition to its own reference file formats (.srf, .trf, and .ref), Smaart can import frequency-Domain data from ASCII text files stored in comma-delimited (.csv) or tab-delimited table formats. This is a handy feature for importing Spectrum or frequency response data from other programs, or creating target curves for Transfer Function or *narrowband* spectrum measurements (to create target curves for banded spectrum measurements see [*Target Curves*](/v1/docs/target-curves)). To import trace data from an ASCII text file, select *Import ASCII* from the data bar menu or *File > Import > Import ASCII* from the *File* menu. This opens the *ASCII Import* dialog. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(77).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A16Z&se=2026-11-18T18%3A42%3A16Z&sr=b&sp=r&sig=hB70f9SCEItYoQUIbAXfdtEG%2FJawpNYqU1bWuvjoNtA%3D) *The ASCII Import dialog.* You will be creating a regular spectrum or transfer function stored data trace and so you will need to specify *FFT Size* and Sample Rate. Together, these two things determine frequency spacing. The current active graph type determines the *Trace Type.* The frequency spacing of data in the imported text file does not need to match the precise FFT bin frequencies for the *FFT Size* and *Sample Rate* that you select. Smaart will automatically interpolate the frequency points that it needs from whatever set of coordinates you supply, using *Linear* or cubic spline *(B-Spline)* interpolation. *B-Spline* is usually the better choice for real signals and smooth functions. *Linear* interpolation may work better for arbitrary curves with sharp corners. The *Name* field sets the name of the trace to be created. To select an ASCII text file for import, click the *Browse* button to bring up the *Load File* dialog and then navigate to your source file and open it. At minimum, the text file to be imported needs to have at least two sets of frequency and Magnitude coordinates. Each set of coordinates occupies a line by itself with the frequency in Hertz in the first position, followed by a column separator character (a comma or tab) and a magnitude value in decibels. For transfer function traces, you can optionally add columns for Phase in degrees and coherence as a fractional value between 0 and 1. Smaart will ignore any line in the file beginning with an asterisk (*) or semicolon (;) so these may be used to add headings or comments to the file. Once all parameters are set, click the *Import* button to import the data from the file. The *ASCII Import* dialog will close, a new data file is created in your session folder on the [Data Bar](/v1/docs/data-bar), and your newly imported trace should appear on the active graph in the graph area. ## Importing Meyer SIM® Data To import transfer function data from Meyer SIM® data files using the *Import* *ASCII* function, first make sure the SIM binary (.bin) and .xml files that you want to import are in the same folder. Open the *ASCII Import* dialog, select SIM.bin in the FFT Size drop-list, then click the Browse button. Navigate to the folder containing the files and open the .bin file then click the Import button in the *ASCII Import* dialog. Smaart will analyze each measurement group within the .bin file and extract room, processor, and resultant traces for each group as Smaart .trf files. For consistency with native Smaart transfer function data, coherence data extracted from SIM data files is square-rooted on import. To display coherence data in Smaart as magnitude-squared coherence, enable the squared coherence *(Squared Coh)* setting in [*Transfer Function* measurement settings](/v1/docs/spectrum-measurement-settings). In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. The frequency content of a given signal. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. The number of times that the amplitude of a signal is measured within a given period of time in analog-to-digital conversion. For audio-frequency signals, sampling rate is typically expressed in samples/second or Hertz. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency.