--- title: "Display (SPL Config)" slug: "display" updated: 2026-07-30T16:25:58Z published: 2026-07-30T16:25:58Z canonical: "doc360.rationalacoustics.com/display" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Display (SPL Config) The *Display* page of the *SPL Config* dialog contains display settings for the SPL History and numeric SPL meters. The latter apply both to the in-Tab SPL/Signal Level meter that appears by default at the top of the control bar in *Real-Time* and Impulse Response (IR) mode in Smaart Suite and meter modules that make up the *SPL Meters* window and the meter bar in both Smaart SPL and Smaart Suite’s SPL mode. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-07-10 at 11-41-35.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A06Z&se=2026-11-18T18%3A42%3A06Z&sr=b&sp=r&sig=twbswzlmHbml%2BAQjuRKVy%2B7AXUnHRNIwah6F0Yf2iUc%3D) *Display tab of the SPL Config dialog.* ## SPL History Settings *Line Thickness* controls set the line thickness for line charts in the SPL History display in Smaart SPL and Smaart Suite’s SPL mode. - *Foreground Trace Thickness* sets the line thickness in pixels for the data trace at the top of the z axis (the frontmost trace) on all line charts. - *Background Trace Thickness* sets the line thickness in pixels for all data traces other than the top trace when multiple traces are displayed on any line chart. ## Meter Display Settings Values displayed on sound level meters (SPL, Leq, and Peak C, A, or Z) change colors according to the sound level thresholds specified in this section. These can be set individually for each measurement type or set once and applied to all measurement types using the *Apply to All* button. Typical usage for this feature would be to set the *Green Above* level comfortably above the self-noise level of your microphone and preamp, so that when the meter text is green, you will know that you are measuring actual sounds. The *Yellow Above* threshold might then be set to a sound level that normally should not be exceeded and *Red Above*, to a level that must not be exceeded. Note that the SG Audio Aps 10EaZy reads its usable range figure directly from the device and ignores the global *Green Above* threshold. Otherwise, these settings apply to all SPL and Leq meters in Smaart SPL and Smaart Suite. To configure thresholds for a single measurement type, select its name in the *Type* list, then enter threshold levels (in decibels) in the *Red Above, Yellow Above,* and *Green Above* fields. You can then apply your new settings to all other measurement types if you like by clicking the *Apply to All* button. You will still be able to adjust thresholds for individual measurement types after doing so. When the *Always on Top* box is checked, the *SPL Meters* window stays in front of all the other windows on your screen when checked regardless of which window has focus. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function.