--- title: "Weighting Curves" slug: "weighting-curves" updated: 2026-05-13T18:32:32Z published: 2026-05-13T18:32:32Z canonical: "doc360.rationalacoustics.com/weighting-curves" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Weighting Curves Weighting curves are how we shape the frequency content of our measurements in Smaart. They are used in real time mode to shape the Magnitude Spectrum of live or stored measurement data. Another way to put it might be to say that filtering in the time Domain equates to weighting in the frequency domain. Weighting curves can be applied to all real-time frequency/magnitude charts in Smaart including RTA, Spectrograph and Transfer Function Magnitude plots. Weighting curves are also used in Sound Pressure Level (SPL) measurements. For more information about SPL weighting, take a look at it’s dedicated article: [Frequency Weighting](/v1/docs/frequency-weighting) ## How to Apply a Weighting Curve To add a weighting curve globally to a live spectrum or transfer function plot, open the *Graph Settings* dialog by clicking the gear icon to the bottom-right of the plot. Here you will see a *Weighting* setting accompanied by a dropdown menu and a *Display Weighting* checkbox. This setting can also be set individually for each measurement engine separately in *Measurement Engine Settings* (both for [Spectrum](/v1/docs/spectrum-measurement-settings-1) and [Transfer Function](/v1/docs/transfer-function-measurement-settings) measurements). ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(231).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=FJF1Xbq9JvZr%2FaXhmYa7b0NA6EQiLXulzG5p%2B%2BHaxEE%3D) *Weighting selection in both Spectrum (left) and Transfer Function (right) Graph Settings.* To add a weighting curve to a captured data trace, use the Weighting selector in the [*Trace Info* dialog](/v1/docs/trace-info). You can open *Trace Info* for a selected file using the *Info* button at the bottom of the Data Bar or by right-clicking said file and select *Info*. ## Custom Weighting Curves By default, Smaart includes *A, C, X,* and *Pink* weighting curves both in their standard forms and as inverted variants. User-defined weighting curves can be created from a captured transfer function trace or imported as an ASCII-formatted .txt file. ## How to Import Weighting Curves To import a weighting curve stored in an ASCII .txt file, select *File > Import > Weighting Curve* or open the *Custom Weighing Curves* dialog (*Options > Weighting Curve*) and then click the *Import* button. Either option will open your operating system’s file browser so that you can find your custom weighting curve file and open it to import the curve data. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(238).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=0Qc%2FqxqF3agc6Vmgkvyhixgkip3Dra1OgQrzj5IJJls%3D) *The Custom Weighting Curves dialog.* ### Weighting Curve Formatting Weighting curve text files need to be in ASCII text format: two columns of data in **Frequency***[Tab]***Level (dB)** format. Smaart will ignore lines beginning with an asterisk (*) or semicolon (;) so these may be used to add human readable headings or comments above these two columns of data. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(241).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=7624u5XYQRQEyPhqxO0xK67AdSWpehI2iTY6T4Go3Oc%3D) *Example weighting curve formatting.* ## Export Captured Transfer Function Trace as Weighting Curve To export a transfer function trace as a weighting curve, select it on the Data Bar, click the hamburger menu (☰) button, and select *Export as Weighting Curve*. Alternatively, you can right-click the desired trace and select *Save As > Weighting Curve.* Doing either causes a dialog to appear, allowing you to name the new weighting curve. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(242).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A06Z&se=2026-11-18T18%3A30%3A06Z&sr=b&sp=r&sig=%2BF9G8ksqB5pidHDsE6XPOKuevcHA1JVbABocLxhr8I8%3D) *New Weighting Curve dialog.* Clicking *OK* in this *New Weighting Curve* dialog will add the new curve to the *Weighting* dropdown list. Smaart automatically creates an inverted version of the curve as well and appends the notation “Inv” to its name. ## Delete Weighting Curve To delete a custom weighting curve, select *Weighting Curves* from the *Options* menu to open the *Custom Weighting Curves* dialog, then click the name of the curve that you no longer want and click the *Delete* button. Deleting a weighting curve removes both the normal and inverted versions. > [!NOTE] > **The standard *A* and *C* (sound level) weighting curves are hard coded in Smaart and cannot be deleted.** 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. The frequency content of a given signal. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. The Real-Time Analyzer (RTA) enables you to look at the frequency content of signals moment-by-moment in real time. The RTA is a graph of the energy in an incoming signal, broken down by frequency or frequency ranges, with frequency (in Hertz) on the x axis and magnitude (energy) on the y axis in decibels (dB) A three-dimensional data plot, displayed in two dimensions with color representing the third dimension (or z-axis). The spectrograph is a topographical representation of the once-common waterfall display. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. The RMS level of pressure waves in air expressed in decibels, referenced to the approximate threshold of audibility for human hearing, where 0 dB is approximately the quietest sound the average human being can detect (and 1 Pascal ≈ 94 dB). SPL is exponentially time-averaged and typically weighted by frequency as well, using standardized Fast or Slow time weighting and A or C frequency weighting curves specified in IEC and ANSI standards for sound level meters..