--- title: "Transfer Function Measurement Engine Settings" slug: "transfer-function-measurement-settings" updated: 2026-05-01T16:44:55Z published: 2026-05-01T16:44:55Z canonical: "doc360.rationalacoustics.com/transfer-function-measurement-settings" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Transfer Function Measurement Engine Settings To view detailed settings for a Transfer Function measurement engine, double-click its control block on the Control Bar or open the [*Measurement Config*](/v1/docs/measurement-config-1) panel and either double-click its color tile in the Measurement Configuration table or select its name and click the *Info* button below the table. Any of these actions will take you to a page with the settings below. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(157).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A09Z&se=2026-11-18T18%3A42%3A09Z&sr=b&sp=r&sig=8OOcfF3Ty%2FG2558ntaUtuOhYKB4RsOcGvyxE4v8dIT8%3D) *Transfer Function Measurement Engine Settings flyup menu.* ## Measurement Settings - The ***Name*** field under *Measurement Settings* sets the measurement name. If you edit the measurement name, be sure to press the [Enter] key to set the change when you are finished. - The ***Delay*** field sets the amount of Signal delay (in milliseconds) needed to align the reference and measurement signals. Positive values delay the measurement signal (the most common case). Entering a negative value delays the reference signal. - ***FFT size*** (in samples) determines the Time Constant and frequency resolution of the frequency Domain displays. When *MTW* is selected, Smaart performs multiple FFTs and combines the results into a single frequency data set. The individual FFT sizes used in this case are not user selectable. **(Suite and RT only)** - ***Averaging Depth*** specifies the length of time over which individual measurements are averaged to stabilize transfer function traces on the analyzer screen and improve their signal-to-noise ratio. Bigger numbers give you longer averaging times. - ***Avgerage Type*** sets the type of averaging used for Magnitude traces. The options are Polar (RMS) or complex (vector). Phase traces always use complex averaging. Polar averaging is probably the most common type for magnitude traces, but both types have their uses. In practical terms, *Polar* averaging lets more reverberant energy into the average, which may tend to agree better with what you hear, particularly for musical program material. *Complex* magnitude averaging tends to reject reverberant energy as noise and may give you better clues regarding speech intelligibility than polar averaging. - The ***FFT, Averaging Depth,*** and ***Average Type*** settings follow the global settings set in the *Transfer Function Measurement Settings* dialog. You can however, set any of these for an individual measurement engine by deselecting its *Use Global* checkbox and selecting a new setting from the drop-list. ## Display Settings - ***Color*** has a clickable tile that, when clicked, opens a color picker dialog to change the display color for the measurement. When committed, these changes apply to all linked copies of the measurement with the same name on other tabs and windows. - ***Plot*** sets the preferred graph assignment for the measurement. It is ignored when only one graph of a given type is displayed. If you bring up a second graph of the same type in the same tab, measurements with a *Plot* setting of 1 (the default setting) will stay with the first instance of the graph and any measurements with a setting of 2 will move to the second. - ***Invert Magnitude Display,*** when checked, will cause Smaart to plot the measurement’s magnitude response upside-down. This can be a handy option when setting loudspeaker EQ curves – a cut filter will plot as a boost and a boost filter as a cut when the measurement is inverted, making it easy to create a complimentary EQ curve. The following settings can be assigned locally or at the graph level for all displayed live measurements. If the Follow Plot check box is checked for any of the following parameters, they will follow changes to the settings in the [*Transfer Function Graph Settings*](/v1/docs/transfer-function-graph-settings-1) dialog and/or on-graph controls. If not, the measurement will keep its own settings and ignore the graph-level settings. - ***Phase Smoothing*** sets the amount of smoothing used for the transfer function Phase display. This option can be set globally or locally for each measurement. - ***Mag Smoothing*** sets the degree of smoothing type for transfer function magnitude traces. This option can be set globally or locally for each measurement. - ***Weighting*** applies a weighting curve to the measurement to reshape its response curve, subtracting from the magnitude values at some frequencies and perhaps adding to them at others. Weighting in the frequency domain is analogous to filtering the measurement signal in the time domain. Common weighting curves include *A* and *C* weighting used for SPL and Leq measurements. **(Suite and RT only)** ## Input Settings This section allows you to make changes to the measurement engine’s routing. - ***Device*** - The I-O device (or driver). - ***Channel*** - The specific input from said I-O device that is being used. - ***Measurement Signal*** - Typically the input corresponding to your measurement mic, used to capture output data from the System Under Test. - ***Reference Signal*** - The signal against which your *Measurement Signal* is compared. This is typically an input receiving your I-O device’s output signal. This can either be accomplished via a physical loopback cable connecting one of your I-O device’s output channels into one of its input channels, or via a digital loopback originating from the I-O device itself or some sort of routing application. [Smaart can also facilitate a digital loopback, if desired.](/v1/docs/smaart-loopback) Normally, both *Measurement* and *Reference* signals will come from the same input device, so the *Device* selection for the *Measurement Signal* is automatically applied to the *Reference Signal* as well. > **Multi-Device TF:** > > It *is* possible to use signals from two different devices if you enable *Allow Multi-Device TF* in [*Options > Preferences > Advanced*](/v1/docs/advanced-preferences-1), but this will only work if both devices’ sample clocks are synchronized. If the devices are out of sync, you will see your measurement’s delay time drift. Additionally, it is important to note that different devices will apply different processing delays to each signal path. As such, a *Multi-Device TF* will often calculate delay times that don’t necessarily correlate to physical distance. ## Global TF Settings Two of the settings in the *Global Spectrum Settings* control group, *Mag Threshold* and *Blanking Threshold*, apply to all transfer function measurements in your configuration. The rest can be all applied globally or localized for individual measurements by un-checking their Use Global check boxes in the *Measurement Settings* control group. - ***Mag Threshold*** sets a normalized Full Scale (dBFS) value that the reference signal must exceed before new data is accepted into the measurement at any given frequency. When the magnitude of the reference signal does not cross threshold at some frequency, new incoming data at that frequency is excluded from the average. - ***Blanking Threshold*** sets the coherence value that must be met or exceeded before a data point at a given frequency is displayed on the graph. This setting applies to both phase and magnitude graphs. The following settings apply to any transfer function measurement that subscribes to the global settings for that parameter: *FFT, Averaging, Mag Avg Type, Phase Smoothing, Mag Smoothing,* and *Weighting*. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency. The term full scale (FS) has two possible meanings in digital signal processing. Normalized full scale refers to the maximum amplitude of a digital signal sampled at a given integer sample word size (bits per sample), scaled to +/- 1.0, such that 0 dB corresponds to the maximum possible peak signal value and all lesser decibel values are negative. A second convention preferred by the Audio Engineering Society (AES) references 0 dB to the RMS value of a full-scale peak-to-peak sinewave (i.e., 0.7071 rather than 1.0). In Smaart, all FS decibel values are referenced to normalized full scale, meaning that the RMS power of a full scale sinewave is -3.01 dB. When using a linear amplitude scale, Full Scale amplitude values are typically given as percentages, where 100% = 1.