--- title: "Synchronous Source (SyncSource™) Measurements" slug: "synchronous-source-syncsource-measurements" updated: 2026-09-22T20:18:35Z published: 2026-09-22T20:18:35Z canonical: "doc360.rationalacoustics.com/synchronous-source-syncsource-measurements" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Synchronous Source (SyncSource™) Measurements ## What is SyncSource™? A hallmark of Smaart’s transfer function measurement process is its ability to measure a system’s response using whatever random signal is passing through it, commonly known as "Source Independent Measurement". This allows engineers to measure their systems under actual use conditions with any reference signal type, or source - console output, prerecorded or live music, third-party noise generators, etc. This allows for an incredible degree of flexibility in terms of signal routing for dual channel measurement. Transfer function measurement with random signals *do* involve certain compromises, most notably the need to apply a data window when the input signals are not periodic. Because an FFT assumes that the input signal is the entire input signal (or alternatively a single, complete cycle of an infinitely repeating signal), and random signals do not repeat, we have to create a “0” point, gradually reducing the start and endpoint of an incoming waveform to zero to avoid, or at least reduce, the amplitude of discontinuities on the edges of our FFT bins. Since raw random signals are inherently non-repeating, they can introduce a significant amount of mathematical noise and instability into the output data. Applying a data window greatly reduces the severity of both issues by conditioning the incoming signals for the FFT (essentially a “fade in” and “fade out” that makes the input signals appear more periodic). This windowing comes at a cost of a slightly raised measurement noise floor. Luckily, neither of these compromises are particularly detrimental to the accuracy of our TF measurement, particularly once adequate averaging is applied. The SyncSource™ transfer function measurement process avoids this issue altogether by using a pseudorandom excitation source (Pink Noise or Sweep) that has a cycle length matched to the length of the FFT being used. Also referred to as a "Source Dependent Measurement”, the SyncSource™ transfer function measurement avoids the use of a data window by using a truly periodic signal. As such, synchronized measurements require the use of Smaart's built-in signal generator to provide the excitation source (Smaart must know what the reference is, and it must not be random). This creates a more deterministic measurement with improved measurement stability and better correlation (and in certain scenarios higher Coherence in turn). One key reason for the higher coherence is that the reverberant energy influencing the measurement becomes functionally correlated with the reference signal and no longer decreases the coherence values. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-12 at 13-35-28.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=arnfQEKE0uHZRgsaxNMj2PCAfqSKZIVPYUYUfgBV3eU%3D) *Example of Random Source TF Measurement (top) versus SyncSource™ TF Measurement (bottom).* --- ## Performing a SyncSource™ Measurement SyncSource™ TF measurements, available exclusively in Smaart Suite and RT, can be enabled via checkbox within the “Advanced” tab of the *Options > Preferences* dialog. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(308).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=XlNTN99xpCEFtH9ZiAXLCBUOUIg2WZhdTVBkP2KsMlQ%3D) When *SyncSource™ TF* is enabled from the [*Advanced* *Preferences*](/v1/docs/advanced-preferences) menu, a drop list for selecting the *Stimulus* Signal type (as *Random* or *Pseudorandom*) appears above the averaging control on the [Control Bar](/v1/docs/control-bar) for Transfer Function measurements. When *Pseudorandom* is selected, an additional dropdown menu appears to select the *Length* of the measurement period, which sets both the stimulus signal sequence length and FFT size of the measurement. The sequence lengths are power-of-two FFT sizes, meaning Magnitude and Phase response data are always calculated using a single Time Window for all frequencies. Coherence can be calculated based on either the *SyncSource* data or an MTW measurement performed simultaneously, depending on whether the *Use MTW Coh* checkbox is checked in [*Transfer Function Measurement Settings.*](/v1/docs/spectrum-measurement-settings#transfer-function-measurement-settings) > [!WARNING] > **Note** > > **Transfer function engines whose FFT selection does not follow the global FFT setting are disabled when performing SyncSource™ measurements.** ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/SyncSource.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=fc%2B8gPbhrr8QhR3vZNRNXHNQL0Ev3%2FTMvE9RO%2BfysMI%3D) *Example of Transfer Function Control Bar with SyncSource™ disabled (left) and enabled (right).* Choosing *Synchronized* as the Stimulus will: - Limit the Signal Generator choices to only *Pseudorandom Noise* or *Sweep.* - Set the *FFT size / Period Length* for both the transfer function measurement engine(s) and the Generator source to the length specified in the Control Bar’s *Length* setting. These controls become inaccessible in [Transfer Function measurement settings](/v1/docs/measurement-settings-global-1#transfer-function-measurement-settings) and [Generator Settings](/v1/docs/signal-generator-measurement-settings). - Limit the available settings for Transfer Function FFT size to 16k and larger. - Disable any Transfer Function engines configured as exempt from Global FFT size setting, and pop an error message stating the same. - Disable the transfer function measurement data window. - MTW is still calculated simultaneously, using the pseudorandom noise source and FFT data windows. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency. The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant.