--- title: "STI & STIPA" slug: "sti-stipa" updated: 2026-07-22T19:30:11Z published: 2026-07-22T19:30:11Z canonical: "doc360.rationalacoustics.com/sti-stipa" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # STI & STIPA ## Why Measure STI & STIPA? In almost all situations where speech is transmitted between a talker and a listener, it is degraded to some degree by the transmission channel. As the speech is degraded, it becomes less intelligible to the listener. This may be due to: - Poor Signal-to-noise ratio - Psychoacoustic masking effects - Sound Pressure Level - Ambient noise level - Reverberation Time (RT60) - Reflections - Loudspeaker frequency response/orientation - Distortion - Background noise - Attenuation over distance/due to obstacles For Public Address & General Alarm (PAGA), Public Address (PA), Voice Address (VA) and alarm systems, it is critical that messages are both audible *and* intelligible so that important instructions can be understood (for instance directions to the nearest exit in the event of an emergency). This is not only a primary concern of potentially hazardous areas such as industrial sites, factories, and oil/gas platforms, but also any area with large crowds such as stadiums, train stations, airports, shopping centers, and hospitals. If emergency announcements are unintelligible or easily misunderstood due to poor system quality, tragic consequences may result. Therefore, it is essential to properly design, install, and verify the speech intelligibility of these reinforcement systems. Those who do so may even have legal or contractual requirements regarding specific speech intelligibility levels, which is where STI and STIPA are useful. ## What Are STI & STIPA? The Speech Transmission Index (STI) has emerged as a go-to metric for objective estimation of speech intelligibility in acoustical systems. STI is a relative of the Articulation Index (AI), which is based on speech-to-noise ratios across a wide range of frequencies. But unlike AI (and its successor, SII), STI also works well for estimating intelligibility in reverberant environments in addition to electronic communication systems. Rather than estimating intelligibility based on direct-to-reverberant or signal-to-noise ratios, STI starts with the concept of speech as a carrier wave (i.e., sound from our vocal cords). This carrier wave is modulated by low frequency fluctuations as the speaker’s mouth and tongue move and change shape to form the phonemes within words. Looking at the example below, a segment of actual human speech, it is not hard to see how someone might arrive at that conclusion. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-01 at 14-19-49.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A10Z&se=2026-11-18T18%3A42%3A10Z&sr=b&sp=r&sig=tss4%2BwMIVh%2FmK17rlq8da9Q4xgD%2Bkm8BaTCzjLY6FnU%3D) *Recording of a male voice saying “Joe took father’s shoe bench out”.* The core concept of STI is that most of the information in speech is carried in these low-frequency modulations, and anything that reduces the depth of the modulations negatively affects speech intelligibility. An advantage of this approach is its sensitivity to just about any factor that works to degrade speech intelligibility in a sound system and/or a room including noise (ambient or electronic), excessive reverberation, distortion, and audible echoes. The basis for calculating STI is the modulation Transfer Function (MTF), which quantifies the depth of modulation in the received signal relative to the transmitted signal at specified frequencies. This modulation transfer function can be either measured directly using specialized “speech-like” test signals or calculated indirectly from the Impulse Response or ETC of a system under test. In either case, it is measured over a range of seven octaves (from 125 Hz to 8 kHz) at fourteen modulation frequencies per band. The modulation frequencies range from 0.63 Hz to 12.5 Hz in 1/3-octave intervals. A general caveat is that STI is sensitive to strongly fluctuating background noise levels, which can lead to overestimation of low intelligibility systems or underestimation of scores on the high end. When measuring in the presence of fluctuating background noise, at least three measurements should be taken and their results averaged to reduce measurement uncertainty. Also, if the speech source and a prominent source of background noise are widely separated, STI may *under*estimate intelligibility – but human hearing can be smarter than machines about that kind of thing. STI is also sensitive to clipping or Amplitude compression in the transmission channel, but in our case those would also violate the linear time-invariant system rule for transfer function measurements. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-01 at 13-59-16.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A10Z&se=2026-11-18T18%3A42%3A10Z&sr=b&sp=r&sig=JirGltc2pqJo9sHfCTdWZ6qjKK7%2FVlx%2FvCd5UFtvl3w%3D) *Modeling modulation loss due to reverberation and noise.* STI estimates speech intelligibility through a transmission channel as a function of modulation loss. In the figure above, the black line is the modulation signal for a transmitted signal. The red line is the modulation signal of the received transmission. The difference between the two (the modulation transfer function or MTF), quantifies loss of modulation due to factors such as reverberation and noise. ### STIPA A historic problem with the direct measurement of STI is that it takes a lot of time. The modulation frequencies are so closely spaced that each one has to be measured separately, and there are 98 (14 frequencies for 7 octaves) modulation frequencies in all. The full direct measurement therefore typically takes about 15 minutes. STI for Public Address systems (STIPA) was developed as a way to get around this problem. STIPA is essentially the same measurement as STI but uses a subset of its modulation frequencies; two per octave, for a total of 14. Alternatively, STIPA is typically uses a speciallized test signal that excites all 14 frequencies at the same time, allowing the measurement to be completed in a single pass. STIPA measurements can be completed in a few seconds and have been found to correlate very well with the results from a more rigorous, full STI measurement. In Smaart, of course, we measure STI indirectly from the impulse response and the full STI measurement takes no longer to perform than a typical direct measurement of STIPA. Smaart *does* provide figures for both STI and STIPA, however, but STIPA in our case is more properly termed STIPA(IR), since it is based on IR data rather than a direct measurement. It is provided for informational purposes, (such as to facilitate comparison with readings from hand-held STIPA meters) and is literally just a subset of the full STI measurement, calculated using exactly the same measurement data. ### Qualitative Thresholds for STI and STIPA STI is calculated from the change in modulation of a test signal, giving a value of between 0 and 1 (1 being the most intelligible and 0 the least). These values (applying to a native speaker of the language being spoken) are evaluated as follows: | STI Range | Quality | | --- | --- | | > 0.75 | Excellent | | 0.60 - 0.74 | Good | | 0.45 - 0.59 | Fair | | 0.30 - 0.44 | Poor | | < 0.30 | Bad | Some versions of the IEC standard on STI have included separate criteria for estimating male vs female speech intelligibility. However, female speech criteria for STI were omitted in the 2020 revision of the standard. Female speech is generally considered to be more intelligible than male speech, and so the worst-case scenario (male speech), makes a better benchmark for evaluating the overall capability of a system to reproduce speech intelligibly. STIPA, alternatively, has always been qualified only for male speech. ## Analyzing STI with Smaart Analyzing STI with Smaart is very simple to do. However, several factors must be considered when measuring an IR for STI analysis in order to obtain a meaningful result. The measurement and analysis procedures for *indirect* STI analysis are so interwoven that it would not make sense to discuss one without the other. [For this reason, we have included a separate article covering these processes.](/v1/docs/calculating-sti) ## AlCons ALCons (sometimes called %ALCons because it is stated as a percentage) stands for Articulation Loss of Consonants. Consonant sounds are critical to speech intelligibility and, since they are short in duration, can tend to get lost more easily than vowel sounds that are voiced over a longer period (and have more total energy as a result). ALCons was originally conceived as an estimate based on room volume, reverberation, and distance of the listener from a sound source. This was commonly called the “architectural” form of ALCons. Later forms used an early-to-late energy ratio in place of room volume and listener distance, theoretically making ALCons directly measurable from an impulse response. The early-to-late energy ratio is conventionally measured in a 1/3-octave band centered on 2 kHz with a split time typically in the range of 10-20 milliseconds. Direct measurement of ALCons from an IR, however, has never been standardized and remains somewhat controversial. That being said, two forms of direct ALCons calculation found their way into a number of acoustical measurement and analysis platforms, including Smaart. The earlier of the two forms did not take background noise into account, making it unsuitable for cases where noise was a significant factor affecting speech intelligibility. A later version that adds an adjustment for noise is informally called “long form” ALCons, to differentiate it from the earlier, “short form” calculation. ALCons is inverted relative to other intelligibility metrics, in that lower values mean *better* scores. ALCons ranges are typically evaluated as such: | ALCons % | Quality | | --- | --- | | < 5% | Excellent | | 5-10% | Good | | 10-15% | Fair | | > 15% | Bad | (STI for public address systems) is a less rigorous variant of STI (see above) intended specifically for use in measuring public address systems. STIPA has been validated only for male speech. The only functional difference in how STI and STIPA are measured is that instead of evaluating 13 modulation frequencies in each octave band, STIPA uses only two frequencies per band to cut down the time required for direct measurement of the modulation transfer functions (MTF). Since Smaart calculates the MTF of a system indirectly from its impulse response and all 13 modulation frequencies required for STI are also used for STIPA (just not in every band) there is no particular advantage to using STIPA in Smaart Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. In acoustics, the amount of time required for audio energy introduced into a system (typically a room) to diminish, or decay by 60 decibels following the cessation of a stimulus signal used to excite the system — e.g., a balloon pop, gun shot or terminated pink noise. It is normally stated band-by-band for individual octave bands. By convention, decay times are normalized to the time required for 60 dB of decay at an observed rate of decay, regardless of the amplitude range actually measured. 60 dB decay time is often referred to as “RT60” or “T60", which is sometimes a source of confusion. And just to confuse things a little more ISO 3382 specifies that it should be called T20 or T30, where the “20" and “30” refer to the decay range actually measured. The main thing to remember is that all of the above refer to 60 dB decay time within a stated frequency range. When a single-number reverberation time is given, according to the ISO standard it should be the average of the reverberation A decrease in the level of a signal. Attenuation can refer to reduction in level for a specified frequency range or a decrease in the overall level. An objective estimate of the intelligibility of human speech transmitted through a transmission medium or system under test. It is based on the relative loss of very low frequency modulation in higher frequency carrier waves. STI is stated as a fractional value between from 0 to 1, where 0 represents a completely unintelligible result and 1 denotes excellent intelligibility with no loss of modulation in transmission. STI is calculated from the modulation transfer functions (MTF) for 7 octave bands from 125 Hz to 8 kHz, and evaluates 13 modulation frequencies in each band. The results for all modulation frequencies in each band are combined into a band-by-band Modulation Transfer Index (MTI) then weighted and summed to produce a single-number STI figure. Separate estimates for the male and female speech may be obtained using different weighting tables when calculating STI. Unless otherwise stated, weighting for male speakers is presumed. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. In signal processing, the maximum deviation from zero in an alternating signal in either the positive or negative direction, typically expressed in volts for an electrical signal, or as a fractional quantity or percentage of Full Scale, in the case of digital signal.