--- title: "SPL Config" slug: "spl-config-dialog" status: "new" updated: 2026-10-28T15:59:45Z published: 2026-10-28T15:59:45Z canonical: "doc360.rationalacoustics.com/spl-config-dialog" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # SPL Config The *SPL Config* command (keyboard shortcut [Ctrl] + [Shift] + [E]) opens the *SPL Config* dialog window, where you can configure sound level measurements and display options for the *SPL Meters* window and SPL History display in Smaart SPL and Smaart Suite. Settings in the *SPL Config* dialog window are grouped into five tabbed pages: - [Display](/v1/docs/display) - [Alarms](/v1/docs/spl-alarms-1) - [Custom Metrics](/v1/docs/custom-spl-metrics) - [Logging](/v1/docs/spl-loggig) - [SPL Compensation](/v1/docs/spl-compensation-1) (Note that the keyboard shortcut for this command does not follow the conventional mapping of the Windows [Ctrl] key to the Mac's [Command] key. The [Ctrl] key is used in both Windows and Mac OS versions of Smaart in this case.) ## Meter Display Settings When the SPL meter is set up for sound level measurement (SPL, Leq, or Peak C) meters change colors according to thresholds specified in this section. These can be set individually for each measurement type or set once and applied to all measurement types. Typical usage for this feature would be to set the *Green Above* level comfortably above the self-noise level of your microphone and preamp, so that when the meter text is green, you will know that you are measuring actual sounds. The *Yellow Above* threshold might then be set to a sound level that normally should not be exceeded and *Red Above*, to a level that must not be exceeded. Note that the SG Audio Aps 10EaZy reads its usable range figure directly from the device and ignores the *Green Above* threshold if it is different. To configure thresholds for a single measurement type, select its name in the *Type* list, then enter threshold levels (in decibels) in the *Red Above, Yellow Above,* and *Green Above* fields. You can then apply your new settings to all other measurement types if you like by clicking the *Apply to All* button. You will still be able to adjust thresholds for individual measurement types after doing so. ## Leq Meter Settings The *Weighting* control sets frequency weighting for Leq measurements. The options are standard *A* and *C* weighting or *None*. Assuming that your microphone and preamps are flat to within the specified tolerances for a given sound level meter performance class from 20 Hz to 20 kHz, a setting of *None* equates to Z weighting. The *Time* field specifies the Leq integration period in minutes. Be sure to press the [Enter] key on your keyboard after editing this setting to set the change.