--- title: "SPL Compensation" slug: "spl-compensation-1" status: "new" updated: 2026-11-03T15:34:15Z published: 2026-11-03T15:34:15Z canonical: "doc360.rationalacoustics.com/spl-compensation-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # SPL Compensation The “SPL Compensation” tab in the *SPL Config* dialog allows you “measure” SPL from a virtually calculated point in space where it might not be possible to place a mic during an event, such as the middle of a dance floor or within an audience seating area. To do this, Smaart compares the levels of a test Signal at both this audience listening position (or Virtual Position) and the mic's final measuring position (or Measurement Location), creating offsets for both A and C weighted SPL measurements. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(84).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A10Z&se=2026-11-18T18%3A42%3A10Z&sr=b&sp=r&sig=mybV7Zb7ol3drtfjRfVCTfgDhstJIHQndZwK2ndPfws%3D) *SPL Compensation Tab in Smaart Suite (left) and Smaart SPL (right).* How to use SPL Compensation: 1. Place your mic in its Virtual [listening] Position (a remote location that would be inaccessible to be measured during a performance) and select your desired calibrated input using the drop down under "Step 1". The end result will be a readout that represents the SPL at this location. 2. Excite your system and click “Capture”. This process takes roughly 20 seconds, tracked by a progress bar. For this purpose, use a test signal that represents the full bandwidth of the sound system, like Pink Noise, at a level high enough above noise floor to ensure that the audio system is fully accounted for. This step varies slightly depending on Smaart edition: **In Smaart Suite:** Generator controls are conveniently included here for this reason. You can turn the noise on/off as needed, but it is not done automatically. **In Smaart SPL:** Since Smaart SPL does not include a signal generator, you will need to use an external source to generate your test signal. 3. Move your mic to its actual Measurement Location. This is the location which will have the offset applied in order to represent the Virtual Location from "Step 1". Select your input again under “Step 2”. You can either select the same calibrated input or a different one (when the same microphone is selected, Smaart assumes you have moved it). This input will be duplicated as a newly selectable, "compensated" input after “Step 5”. 4. Excite your system using the same test signal at the exact same level used in "Step 1", then click the “Calculate” button under "Step 2". When this button is pressed, 15 second LAeq and LCeq measurements are calculated and compared to the values previously captured at the Virtual Location. The resulting offsets for A and C weighting will be displayed in the text fields under “Result”. 5. Click "Add" to save these offsets to the input selected in "Step 2". This will create a new SPL input in the SPL Compensation table. By default, this is named after the original input followed by “(compensated)”, but can be renamed if desired. To do so, click its name and it will turn into an editable text field. **These inputs are display-only and won’t create data in any generated logs.** When selecting an input for an SPL meter or to set an alarm, your compensated input(s) are now available for selection, although they won’t generate data for a log. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/base64-converted-image-1782327571938.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A10Z&se=2026-11-18T18%3A42%3A10Z&sr=b&sp=r&sig=Rp3IAJe13nOgLAj8aTvE4b%2Fk8Iyg532F8X1%2F3jeE5jw%3D) Compensation is only applied to A- and C-weighted metrics, which will be the only metrics available in the metric drop down for a compensated input. If the LAeq and/or LCeq correction fields are set to 0, the metrics for that weighting are shown in red to indicate that a compensation offset has not been set. Below are a few examples of SPL Offset Values and how they affect these virtual Compensated inputs: | **Loudest Location Results** | 94 dB SPL Laeq 15s | 110 dB SPL LAeq 15s | | --- | --- | --- | | **Measurement Location Results** | 89 dB SPL LAeq 15s | 113 dB SPL LAeq 15s | | **SPL Offset Value** | A weight = +5 dB offset | C weight = -3 dB offset | Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy.