--- title: "Spectrum Measurement Engine Settings" slug: "spectrum-measurement-settings-1" updated: 2026-05-04T15:29:42Z published: 2026-05-04T15:29:42Z canonical: "doc360.rationalacoustics.com/spectrum-measurement-settings-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Spectrum Measurement Engine Settings To view detailed settings for a Spectrum measurement, double-click its control block on the Control Bar or open the [*Measurement Config*](/v1/docs/measurement-config-1) panel and either double-click its color tile in the Measurement Configuration table or select its name and click the info button below the table. Any of these actions will take you to a page with the settings below. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(158).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A15Z&se=2026-11-18T18%3A42%3A15Z&sr=b&sp=r&sig=P3XRe1zDBYqEcMD6e0%2Fgzj7gStMVBRB4mAuteQ4aC08%3D) *Spectrum Measurement Engine Settings flyup menu.* ## Measurement Settings - The ***Name*** field under *Measurement Settings* sets the measurement name. If you edit the measurement name, be sure to press the [Enter] key to set the change when you are finished. - The ***Delay*** field sets the signal delay for the measurement in milliseconds. For spectrum measurements this will normally be 0.00, but there may be special cases you would want to delay a signal for display purposes. - ***FFT size*** (in samples) determines the Time Constant and frequency resolution of the frequency Domain displays. Increasing FFT size provides finer frequency resolution, enabling you to distinguish features more closely spaced in frequency, but does so at the expense of time resolution, the ability to resolve features transient of a signal that are closely spaced in time. In general, the default setting of 16K points is a pretty good trade-off between the two that works well for most applications, given a sampling rate of 44.1k or 48k samples per second. - ***Averaging Depth*** specifies the length of time over which individual measurements are averaged to smooth and stabilize the traces or bar graphs on the screen. Bigger numbers give you longer averaging times. The ***FFT*** and ***Averaging Depth*** settings normally follow the global settings for spectrum measurements set in the *Spectrum Measurement Settings* dialog. You can however, set either or both of these setting independently for an individual measurement engine by un-checking its *Use Global* check box and selecting a new setting from the drop-list control. ## Display Settings - ***Color*** has a clickable tile that, when clicked, opens a color picker dialog to change the display color for the measurement. When committed, these changes apply to all linked copies of the measurement with the same name on other tabs and windows. - ***Plot*** sets the preferred graph assignment for the measurement. It is ignored when only one graph of a given type is displayed. If you bring up a second graph of the same type in the same tab, measurements with a *Plot* setting of 1 (the default setting) will stay with the first instance of the graph and any measurements with a setting of 2 will move to the second. - ***Weighting*** applies a weighting curve to the spectrum measurement to reshape its spectrum, subtracting from the level values at some frequencies and perhaps adding to them at others. Weighting in the frequency domain is analogous to filtering the in the time domain. Common weighting curves include *A* and *C* weighting used for SPL and Leq measurements. **(Suite and RT only)** If the *Follow Plot* checkbox is checked for *Weighting* this setting follows changes to the global weighting setting for spectrum measurements set in the *Spectrum Graph Settings* dialog and/or via the on-graph weighting control if applicable. Un-checking this box enables you to set weighting specifically for the individual measurement. ## Input Settings Input settings for spectrum measurements consist of a single input *Device* and *Channel* selection. - ***Device*** - The I-O device (or driver). - ***Channel*** - The specific input from said I-O device that is being used. The frequency content of a given signal. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays.