--- title: "The Signal Generator" slug: "signal-generator-measurement-settings" updated: 2026-04-30T14:25:59Z published: 2026-04-30T14:25:59Z canonical: "doc360.rationalacoustics.com/signal-generator-measurement-settings" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # The Signal Generator The *Signal Generator* options dialog is a fly-up menu designed to fit within the area of the Control Bar. This new compact interface allows the manipulation of generator settings with an unencumbered view of the data plots. The Signal Generator and its settings can be accessed using the [Alt] + [N] Hotkey or by clicking *Signal Generator* on the Control Bar. When the *Compact Signal Generator* signal layout is selected, clicking on the signal level will open the dialog. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(107).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A15Z&se=2026-11-18T18%3A30%3A15Z&sr=b&sp=r&sig=W6LO%2Ba%2F9%2Bk%2Bs9GuhJwkcc7X5XObzOC6LqTm66eoNlu8%3D) *The Signal Generator Settings dialog fly-up.* In addition to signal type, outputs, level controls, and a *generator On/Off* button, this menu reveals a checkbox to set the interface to compact view, a checkbox to stop the generator once you’ve captured a trace, and an *Output Config* button. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(150).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A15Z&se=2026-11-18T18%3A30%3A15Z&sr=b&sp=r&sig=npt7FnxD5H6WThc1TxLPUC0Te92LwRaFFsZkEJxMgOk%3D) *Standard (left) and compact (right) views of Signal Generator controls.* If you enable *Compact Signal Gen* and can’t remember the hotkey to reopen this menu, don’t fret—you can find a third way to open the fly-up dialog under the *Options* menu. Otherwise, simply click on the textbox displaying the generator level. Smaart LE features the compact view, exclusively. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(151).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A15Z&se=2026-11-18T18%3A30%3A15Z&sr=b&sp=r&sig=6ltyIUZXsTw84AMMEeMdtTnA%2BLYcYoMJoLvExNbJQ5k%3D) The *Signal Generator* options dialog has a *Signal* selector in the upper left corner that sets the type of output signal to be generated. All signal types have a *Level* control that sets the digital output level in dBFS and a *Stop Gen after Capture* option that turns off the generator automatically after you capture a measurement (i.e., when you perform a reference trace capture or a *Capture All* operation in real-time mode, or at the conclusion of a new measurement in IR mode). Other options vary depending on the selected signal type. The *Output Config* button in the lower left corner of the dialog that takes you directly to the [*Outputs*](/v1/docs/output-config-1) tab of the *I-O Config* dialog, where you can select the output devices and channels to which you wish to stream the signal generator output. The *Output* dropdown at the top allows you to quickly switch between output presets. Output presets can be configured while the signal generator is running. ## Noise Types Smaart can generate two basic types of noise: *“Random”* or *Pseudorandom*. *“Random”* noise is created by streaming the output of a pseudorandom number generator (PRNG) with an extremely long cycle time through a digital filter network. The PRNG is randomly seeded every time you start the generator and so, given its cycle length (about 12.5 hours at 48 k sample rate), it effectively will not give you the same noise sequence twice. *Pseudorandom* noise signals in Smaart repeat on intervals that are a power-of-two samples in length up to 220 (1024K) samples. These can be band-limited or shaped to an idealized long-term average speech spectrum (LTASS) in addition to broadband noise. When using pseudorandom noise, you should always select a cycle length that is at least as long as the longest FFT size that you will be using for measurements. For example, the longest Time Window used in the MTW Transfer Function is a little over one second and so 64K would be the lower limit in that case, but noise sequences even that short tend to become hard to listen to pretty quickly. For real-time frequency-domain measurements in general, 512K is generally a good choice for cycle length, however you might wish to increase that to 1024K when using a Sample Rate in excess of 48000 samples/sec. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(108).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A15Z&se=2026-11-18T18%3A30%3A15Z&sr=b&sp=r&sig=q0xWD0v4U0RKc8ZHK%2FiIGtDiRBSG8eehgDC8IiL1aiQ%3D) *Spectrum view of all Noise Contours.* For Impulse Response measurements in [IR mode](/v1/docs/ir-mode-main-graph-area), it is common to use pseudorandom noise with a cycle period matched the to the FFT Time Constant, so that the measurement can be recorded without a data window. The *Drop IR Data Window* option automatically sets the sequence length to match the FFT size for dual-channel measurements in IR mode. There are four spectral shaping options (or "noise contours") for pseudorandom noise: *Pink, Pink-Red, Red,* and *Speech Weighted*. now accessible via the *Contour* menu). - ***Pink*** noise has a spectrum that appears flat on a fractional-octave RTA display and rolls off at 3 dB per octave (10 dB per decade) on a narrow-band frequency scale. - ***Red*** noise (sometimes referred to as brown noise) exhibits a 6dB decrease in energy per octave, or a power spectrum proportional to 1/freq2. This noise source has a significant amount of low-frequency energy and should not be considered a reliable noise source for finding delay times with transfer function measurements. - ***Pink-Red*** noise is a hybridized noise contour created by Rational Acoustics which transitions from pink to red at 1kHz. This way, the HF energy transitions to a Red contour higher in frequency, making it more useable than Red noise for full range systems while not exciting as much high frequency content (which can be fatiguing to both our ears and our loudspeakers). - ***Speech Weighted*** noise has a spectral shape based on the STI test signal spectrum (without notching) as defined in IEC 60268-16:2020. Checking the *Band Limited* option activates the *Start Freq* and *Stop Freq* controls to specify your desired passband. When changes are made to this setting while the signal generator is active, a brief fade-in will trigger to prevent speakers from popping or clicking at higher levels. ## Output The *Output* selection under the band-limiting controls changes the output scheme of the noise seed. - ***Mono:*** When selected, the same noise seed is sent to each output that is enabled. This is the default selection for noise. - ***Stereo:*** When selected, Smaart will generate two different noise seeds: one sent to all enabled odd-numbered output channels, and a second sent to all enabled even-numbered output channels. > [!WARNING] > Warning! > > It is absolutely necessary to use the same noise seed for both your loopback and your output. If you use two different noise seeds for a dual-channel measurement, you will be unable to produce any useful data. - ***Multi (Multi-channel):*** This selection is disabled unless pseudorandom noise is selected. Each output enabled for use will have a unique noise seed. Using this setting, there is no limit to the number of channels that can have a unique output seed. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(109).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A15Z&se=2026-11-18T18%3A30%3A15Z&sr=b&sp=r&sig=PKqVlHYzXStsT%2BRu9RLgfM766eA6xjvuOVg5%2B0lQuQI%3D) *Output selection for noise seed, Noise stimulus.* When the *Fade In* checkbox is engaged, Smaart will gradually increase the signal level over a user-definable period of seconds (rounded to tenths of a second) until the specified level is reached, each time you start the generator. This is set to 1.5 seconds by default. Digital signal levels for all noise signals are calibrated to normalized Full Scale (dBFS), meaning that the maximum possible peak Amplitude for a given number of bits per sample is scaled to 0 dB. Random and pseudorandom Pink Noise signals are hard limited to ensure a peak-to-RMS ratio of 12 dB (Crest Factor = 4). ## Pink Sweep The *Pink Sweep* signal is a logarithmic sinusoidal sweep primarily intended for use in impulse response measurements for room acoustics analysis. In impulse response (IR) mode you can use the *Triggered by impulse response* option to automatically set the sweep length to match the FFT size used for the IR measurement and trigger the generator automatically when you start a measurement. Note that you will typically use little or no averaging when using sweeps to make an IR measurement, as there is little to be gained by averaging multiple measurements in that case. When the *Zero Pad* checkbox is engaged, Smaart will insert a period of silence at the beginning and end of the sweep signal. This option should be turned on when performing “one-shot” measurements, where the system is in an unexcited state when the measurement begins. For steady state measurements, where the system is kept in a continually excited state, un-check this box so that the sweeps signal plays end to end without interruption. IR measurements can be performed as either one-shot or steady state measurements but the one-shot technique is most commonly used. Real-time measurements using sweeps should always be performed as steady state, period-synchronous measurements, with zero-padding and data windowing turned off and the FFT size matched to the sweep sequence length. ## Sine and Dual Sine Waves The options for *Sine* waves and *Dual Sine* signals are essentially identical. *Sine* is enabled by default, and a new checkbox is present to enable *Dual Sine* and allow changes to the bottom row of controls (*Level 2* and *Freq 2*). The relative signal level for each sinewave generator (*Level 1* and *Level 2*) is set independently and the master *Level* control controls the overall signal level. Note that Smaart does not use the AES convention for digital Full Scale (dB FS) when stating output levels for test signals. When *Show Peak* is selected, signal levels for output signals are stated relative to normalized full scale peak, meaning that given a full-scale sinewave, the maximum peak amplitude is 0 dB (not +3 dB) and the RMS level would be −3 dB (not 0 dB). file playback The *Stop Gen after Capture* option automatically stops the signal generator if it is running after you capture a reference trace or perform a *Capture All* operation. ## File-based Signals ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(152).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A15Z&se=2026-11-18T18%3A30%3A15Z&sr=b&sp=r&sig=0nTdK6jvqKSwS887CpgHZVz7Jn2qWmZ6mwRxrTUs620%3D) In addition to internally generated signals, Smaart also lets you use any .wav file as a test signal. Introduced in 9.5, a new multi-file playback system has been added to the signal generator, akin to a basic media player. When clicking *Browse*, the system file explorer will open and allow selection of multiple tracks. Selected tracks are then added to the list and will be played from top to bottom; you can click and drag to re-order them. When new tracks are imported, any previous ones will not be deleted. Two options are available when right-clicking a file loaded into the Signal Generator: *Remove* to remove a file from the list and *Import* (which opens the file browser, like when clicking *Browse*). The three buttons under this list are *Previous Track, Repeat,* and *Next Track*. Selecting *Repeat* will repeat the selected file rather that going to the next track in the list. When the *Normalize* option is checked, Smaart will scale the signal to a peak level of 0 dB normalized full scale. There are two options for outputting the signal: *Mono* and *Stereo+*. *Mono* sums all audio channels of the file and sends that mono sum to all outputs. With a 2-channel stereo file, *Stereo+*, the first channel of a .wav file is sent to all odd numbered channels (1, 3, 5, etc), and the second channel of a .wav file is sent to all even numbered channels (2, 4, 6, etc). If the file contains more than 2 channels, then all channels are accommodated in the order they are presented. For example, if a 5.1 channel (FL/FR/Center/LFE/SL/SR) file is played, and outputs 1, 2, 3, 4, 5, 6 are selected – those channels would receive the outputs as presented from the file (i.e. channel 1 from the file plays to output 1 of Smaart, channel 2 to output 2, etc). Also, be aware that Smaart copies the entire file into RAM to provide seamless looping, so you may want to try and keep your file lengths fairly short. The *Stop Gen after Capture* option automatically stops the signal generator if it is running after you capture a reference trace or perform a *Capture All* operation. ## SMTPE This selection configures the signal generator to output a noise signal that corresponds to the Society of Motion Picture and Television Engineers definition in the SMPTE ST 2095-1 draft. There are no user-definable settings for SMPTE noise. SMTPE Noise has the following characteristics: | Crest Factor | 11.5 - 12 dB | | --- | --- | | Pink Noise signal bandwidth | 10 Hz - 22.4 kHz | | Energy uniformity | +/- 0.25dB for any 1/3oct band from 20 Hz – 16 kHz | | Min. unique signal period | 10 secs | The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. The number of times that the amplitude of a signal is measured within a given period of time in analog-to-digital conversion. For audio-frequency signals, sampling rate is typically expressed in samples/second or Hertz. The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. The Real-Time Analyzer (RTA) enables you to look at the frequency content of signals moment-by-moment in real time. The RTA is a graph of the energy in an incoming signal, broken down by frequency or frequency ranges, with frequency (in Hertz) on the x axis and magnitude (energy) on the y axis in decibels (dB) The term full scale (FS) has two possible meanings in digital signal processing. Normalized full scale refers to the maximum amplitude of a digital signal sampled at a given integer sample word size (bits per sample), scaled to +/- 1.0, such that 0 dB corresponds to the maximum possible peak signal value and all lesser decibel values are negative. A second convention preferred by the Audio Engineering Society (AES) references 0 dB to the RMS value of a full-scale peak-to-peak sinewave (i.e., 0.7071 rather than 1.0). In Smaart, all FS decibel values are referenced to normalized full scale, meaning that the RMS power of a full scale sinewave is -3.01 dB. When using a linear amplitude scale, Full Scale amplitude values are typically given as percentages, where 100% = 1. In signal processing, the maximum deviation from zero in an alternating signal in either the positive or negative direction, typically expressed in volts for an electrical signal, or as a fractional quantity or percentage of Full Scale, in the case of digital signal. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy.