--- title: "Room Volume, Absorption, and Reverberation Time (RT60)" slug: "room-volume-absorption-and-reverberation-time-rt60" updated: 2026-07-22T19:30:17Z published: 2026-07-22T19:30:17Z canonical: "doc360.rationalacoustics.com/room-volume-absorption-and-reverberation-time-rt60" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Room Volume, Absorption, and Reverberation Time (RT60) Reverberation Time is typically measured or calculated for a [60dB decay range (RT60)](/v1/docs/reverberation-time). The following information will help you to appreciate the factors that affect reverberation time so that, after measurements have been made, appropriate changes can be suggested where necessary. RT60 is heavily dependent on room volume, the amount of absorption in the room, and air absorption at higher frequencies. A popular approximation, based on Sabine’s formula, is: ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-03 at 13-55-08.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A16Z&se=2026-11-18T18%3A30%3A16Z&sr=b&sp=r&sig=DGEp3md5Zm8jL8WT4Op1sK0qT0iy8U1F4ahrozRUb%2BQ%3D)Where: - ***RT*** is the time it takes for reverberant sound energy to decay by 60dB (in seconds) - ***V*** is the volume of the room in cubic meters - ***c*** is the Speed of Sound in meters/second (varies with temperature) - ***A*** is the total sound absorption of room materials in square meter Sabines – i.e. the sum of surface areas, each multiplied by its respective sound absorption coefficient - ***m*** is the intensity Attenuation coefficient of air per meter (varies with temperature and humidity) ## Typical Material Absorption Coefficients *Note that absorption coefficients vary with frequency.* | Material Type | Typical Mid-Band Sound Absorption Coefficient | | --- | --- | | Marble | 0.01 | | Plastered Walls | 0.02 | | Bare Brick | 0.03 | | 10mm Plywood | 0.09 | | 10mm Mineral Wool | 0.60 | | 25mm Polyurethane Foam | 0.70 | | Acoustic Ceiling Tile | 0.72 | | Audience Member on Upholstered Seat | 0.88 | [A more in-depth list can be found here.](https://www.sengpielaudio.com/calculator-RT60Coeff.htm) ## Air Absorption Air absorbs sound quite significantly at higher frequencies due to molecular resonance. This high frequency air absorption varies with temperature and relative humidity in a way too complex to cover here. [For further information, a useful air absorption calculator may be found here.](http://resource.npl.co.uk/acoustics/techguides/absorption/) ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-03 at 14-05-34.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A16Z&se=2026-11-18T18%3A30%3A16Z&sr=b&sp=r&sig=CwiqBHqw%2FFCG0gFXPaDmYBL9XHZE9Q6vLtVvVqZLJhk%3D) *Air absorption (in dB/m) vs. relative humidity at room temperature.* Note that sound absorption through air is per meter – not per doubling of distance as seen for radial attenuation. Sound in a room with a mid-band RT60 of roughly 2 seconds will travel several hundred meters before decaying into the noise floor so air absorption is a significant additional factor in reducing high frequency reverberation times. ## Schroeder Cut-Off Frequency RT60 assessments are usually restricted to the Schroeder Frequency (or critical frequency). This is the crossover point between the stochastic region (high frequency range where sound paths are diffuse and random) and modal region (low frequency range heavily affected by room modes). In the region surrounding the Schroeder Frequency, modes start to overlap by a fairly arbitrary factor of three. The popular approximation published by Schroeder in 1962 is: ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-03 at 15-04-17.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A16Z&se=2026-11-18T18%3A30%3A16Z&sr=b&sp=r&sig=1RNBzi7UrZ0XwKprsUobAgppNXXKS7kAU5QUCWG9HhM%3D) As before, RT is the time taken for the reverberant sound energy to decay by 60dB (in seconds) and V is the volume of the room in cubic meters. For room volume in cubic feet, the equation can be written as:![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-03 at 15-05-13.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A16Z&se=2026-11-18T18%3A30%3A16Z&sr=b&sp=r&sig=nV94vtC%2FQk%2BR5JOL%2B4qFkgOOecEe3NquI3wcR4Y8nYI%3D) ## Practical Measurement Considerations Most of the above equations are approximations that assume an omnidirectional sound source, homogenous sound distribution, and the possession of accurate venue information! In reality (where we typically perform our measurements), accurate venue information may be difficult to acquire and operating conditions may vary from event to event. Reverberation characteristics are also likely to vary slightly across the audience area and early decay characteristics will vary significantly from seat to seat. Because of this, accurate measurements, over a practical range of operating conditions, are recommended. As most rooms have significant background noise levels (the noise floor), a full 60dB decay range isn’t always available – especially when the direct sound is at normal speech levels or, as is possible with Smaart, we measure a system with an audience in place. For convenience, instead of measuring the full 60 dB decay time, the decay slope (in dB per second) is measured over a 30 dB range (preferred) and then doubled to work out the RT60. This scaling works, similarly to a car’s spedometer - You do not need to drive for an hour to understand how far you *would* travel if you continued at your current speed. For a T30 measurement, slope is conventionally measured between the -5dB and -35dB points, as long as the lower point is at least 10dB above the noise floor. If the noise floor is exceptionally high, it may sometimes be necessary to measure the decay slope over a smaller level range. In that case a 20 dB range may be measured instead and then tripled to normalize to equivalent 60 dB decay time. According to ISO 3382, reverberation time measured over a 30 dB range is called T30 and T20 signifies a 20 dB measured range. In their notation scheme, the letter T, by itself, stands for 60 dB decay time and so hopefully it is understood that the 20 and 30 refer only to the measured range. The stated reverberation time in seconds for either figure is the equivalent 60 dB decay at the measured rated of decay. Typical values are as follows: | Venue | Reverberation Time (In Seconds) | | --- | --- | | Talk Studio | < 0.5 | | Cinema/Auditorium | 0.4 - 1 | | Conference Room/Classroom | 0.1 - 1 | | Musical Theaters | 1 - 1.5 | | Chamber Music/Opera Venues | 1.5 - 2 | | Symphony Halls | 1.5 - 2.5 | In practice, of course, acceptable ranges vary with expectations based on the venue size. In acoustics, the amount of time required for audio energy introduced into a system (typically a room) to diminish, or decay by 60 decibels following the cessation of a stimulus signal used to excite the system — e.g., a balloon pop, gun shot or terminated pink noise. It is normally stated band-by-band for individual octave bands. By convention, decay times are normalized to the time required for 60 dB of decay at an observed rate of decay, regardless of the amplitude range actually measured. 60 dB decay time is often referred to as “RT60” or “T60", which is sometimes a source of confusion. And just to confuse things a little more ISO 3382 specifies that it should be called T20 or T30, where the “20" and “30” refer to the decay range actually measured. The main thing to remember is that all of the above refer to 60 dB decay time within a stated frequency range. When a single-number reverberation time is given, according to the ISO standard it should be the average of the reverberation The speed at which sound waves propagate through a transmission medium such as air or water. This quantity has dependent actors such as temperature and density of the material of propagation. Useful rule-of thumb values for the speed of sound in air at room temperature are 1130 ft/sec, or 344 m/sec. In Smaart the speed of sound is used primarily to calculate distance equivalents for time differences. A decrease in the level of a signal. Attenuation can refer to reduction in level for a specified frequency range or a decrease in the overall level.