--- title: "Program Focus" slug: "program-focus" updated: 2026-06-05T16:27:20Z published: 2026-06-05T16:27:20Z canonical: "doc360.rationalacoustics.com/program-focus" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Program Focus In Smaart, left-clicking on a plot will put it in focus. When a plot is in focus, the lines that form its border will become thicker. For instance, in the bottom screenshot the top plot is in focus: ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(279).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A29%3A56Z&se=2026-11-18T18%3A29%3A56Z&sr=b&sp=r&sig=kvPrrOCUnJKF%2BoXbJZp5mhbegJ526mCBsimfmNjDjG8%3D) When a plot is in focus, any hot keys or other commands are made to that specific plot. This can include any zooming, scrolling, or other manipulations of data. This is important to keep in mind, as there will be times (such as in Transfer Function view) that different types are data are displayed simultaneously in different plots. In the screenshot below, for example, the Phase plot is in focus. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(305).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A29%3A56Z&se=2026-11-18T18%3A29%3A56Z&sr=b&sp=r&sig=PjipZFWw43XzajWZIdJqXKsADrDhWMwURVh8IQJHk9A%3D) *With the Phase plot focused, the “Show Target Curves” option is greyed out.* This is fine and good if you’re looking to scroll or zoom in on the phase trace, but this will prevent you from being able to display Target Curves. Since they appear on the Magnitude plot, Target Curves cannot be shown using the [X] hot key and their option in the *View* dropdown menu is greyed out. In order to show Target Curves, left-click the Magnitude plot to bring it into focus. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude.