--- title: "Plot Calibrated Level" slug: "plot-calibrated-level" updated: 2026-06-05T14:22:44Z published: 2026-06-05T14:22:44Z canonical: "doc360.rationalacoustics.com/plot-calibrated-level" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Plot Calibrated Level *Plot Calibrated Level* is a setting that can be made active in the Spectrum page of the *Graph Settings* dialog. This menu is accessible by selecting *Options > Graph Settings > Spectrum*, using the [Alt/Option] + [S] hot key, or by clicking the settings button (![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(101).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A06Z&se=2026-11-18T18%3A42%3A06Z&sr=b&sp=r&sig=6AEQMcR0MkcnT9vBIA6YLuRHD%2BOkUVUQTqPqTGWdwcc%3D)) in the lower-right corner of any Spectrograph or RTA graph in any main window graph area. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(268).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A06Z&se=2026-11-18T18%3A42%3A06Z&sr=b&sp=r&sig=w581Gm6qfTwtkOdfBSLSZ%2FP2v0JzUxYVhJ7N5K5VnMc%3D) *Plot Calibrated Level setting in Spectrum Graph Settings.* When enabled via checkbox, *Plot Calibrated Level* applies input calibration offset (e.g., for SPL calibration) to RTA measurements (if applicable) and changes the default RTA display range to 20 dB to 120 dB. Note that this will result in a drastic difference in scale between data from inputs calibrated to SPL and inputs calibrated to digital Full Scale. When this option is not selected, Smaart ignores input sensitivity calibration and references all spectrum measurements to digital Full Scale. The default Magnitude range for RTA displays in that case is 0 to −100 dB. By default, the y axis of the RTA plot displays level using dB Full Scale. However, since Spectrum target curves are set to specific sets of frequencies, this can mean that they sit incredibly high above any displayed data. When *Plot Calibrated Level* is enabled, however, any data from a calibrated input will be displayed within usable range of any target curve (assuming that the SUT is set to a suitable level for measurement). in the top-right corner of the plot. As the logging continues, you will see a separate trace for the level of each octave band. To view the plot of a particular band, you can either cycle to it in the top plot or bring it to the front of the Z-order in the top-right drop-down menu. The frequency content of a given signal. A three-dimensional data plot, displayed in two dimensions with color representing the third dimension (or z-axis). The spectrograph is a topographical representation of the once-common waterfall display. The Real-Time Analyzer (RTA) enables you to look at the frequency content of signals moment-by-moment in real time. The RTA is a graph of the energy in an incoming signal, broken down by frequency or frequency ranges, with frequency (in Hertz) on the x axis and magnitude (energy) on the y axis in decibels (dB) The term full scale (FS) has two possible meanings in digital signal processing. Normalized full scale refers to the maximum amplitude of a digital signal sampled at a given integer sample word size (bits per sample), scaled to +/- 1.0, such that 0 dB corresponds to the maximum possible peak signal value and all lesser decibel values are negative. A second convention preferred by the Audio Engineering Society (AES) references 0 dB to the RMS value of a full-scale peak-to-peak sinewave (i.e., 0.7071 rather than 1.0). In Smaart, all FS decibel values are referenced to normalized full scale, meaning that the RMS power of a full scale sinewave is -3.01 dB. When using a linear amplitude scale, Full Scale amplitude values are typically given as percentages, where 100% = 1. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude.