--- title: "Measurement Settings (Global)" slug: "measurement-settings-global-1" status: "update" updated: 2026-10-28T18:32:29Z published: 2026-10-28T18:32:29Z canonical: "doc360.rationalacoustics.com/measurement-settings-global-1" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Measurement Settings (Global) ## Spectrum Measurement Settings ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(159).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A14Z&se=2026-11-18T18%3A42%3A14Z&sr=b&sp=r&sig=8ZhOAsUZzXpdROk%2F5EvIuTCECAAXri0LQ3vpzzmTxpA%3D) - ***Data Window*** sets the data window function, used to precondition time domain signals before performing an FFT for narrowband spectrum measurements (banded spectrum measurements always use a *Hann* window). The default setting is *Hann*, which is generally a good place to leave it unless you have some good reason to change it. - ***FFT size*** (in samples) determines the time constant and frequency resolution of the frequency domain displays. Increasing FFT size provides finer frequency resolution, enabling you to distinguish features more closely spaced in frequency, but does so at the expense of time resolution, the ability to resolve features transient of a Signal that are closely spaced in time. In general, the default setting of 16k is a pretty good trade-off between the two that works well for most applications, given the default Sample Rate of 48k. - ***Averaging Depth*** specifies the length of time over which individual measurements are averaged to smooth and stabilize the traces or bar graphs on the screen. Bigger numbers give you longer averaging times. --- ## Transfer Function Measurement Settings ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(160).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A14Z&se=2026-11-18T18%3A42%3A14Z&sr=b&sp=r&sig=nPWYGjlceIoEP81jBMaD2GkWqWhrM4s9eDrQGZhYedo%3D) General Settings - ***FFT size*** (in samples) determines the Time Constant and frequency resolution of the frequency Domain displays. When *MTW* is selected, Smaart performs multiple FFTs and combines the results into a single frequency data set. The individual FFT sizes used in this case are not user selectable. **(Suite and RT only)** - ***Averaging Depth*** specifies the length of time over which individual measurements are averaged to stabilize transfer function traces on the analyzer screen and improve their signal-to-noise ratio. Bigger numbers give you longer averaging times. - ***Mag Threshold*** sets a normalized dBFS value that the reference signal must exceed before new data is accepted into the measurement at any given frequency. When the Magnitude of the reference signal does not cross threshold at some frequency, new incoming data at that frequency is excluded from the average. Live IR & Delay Tracker - ***FFT Size*** sets the FFT frame size (in samples) for the Live IR display. The resulting time constant, based on the current sample rate setting in *Audio Options*, is calculated and displayed for each available FFT size. - ***Averaging*** sets the number of averages used for the Live IR display. Increasing this value may provide a more stable display at the expense of responsiveness. Increasing this value will also give you a better chance of capturing a usable Live IR measurement when measuring under difficult conditions. Delay Finder - ***FFT size*** and ***Averages***- The default is a 64k FFT with no averaging, which works out to a time constant of 1365 ms at 48k sample rate. This is sufficient for finding delay times at distances up to about 450 feet (140 meters) from a source. A good rule of thumb is that the FFT time constant should be least three times greater than the expected delay time. When measuring from extremely long distances or using a sample rate greater than 48k, you may need to increase the FFT size. When working in very noisy surroundings, increasing the number of averages may help as well. - ***Increment*** allows you to set how much delay is applied with each press of the + and - buttons on your Transfer Function measurement engine. The frequency content of a given signal. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. The number of times that the amplitude of a signal is measured within a given period of time in analog-to-digital conversion. For audio-frequency signals, sampling rate is typically expressed in samples/second or Hertz. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude.