The current configuration in Smaart includes the names, layouts and locations all of your windows and tabs, audio device selections including friendly names and calibration settings, measurement setups for each tab, along with view presets, and all but a handful of menu and dialog settings. It is updated each time you make a settings change and stored to a .xml file on shutdown, so that the Smaart can “remember” all of your settings, measurement configurations, and preferences the next time you run it.
Config Management Dialog
.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A23%3A58Z&se=2026-11-18T17%3A36%3A58Z&sr=b&sp=r&sig=HzPDG3zr1oj7QdN8Mt4frWHWHAd9En1b%2FBNg%2FeuF4jk%3D)
The Config Management dialog.
The Config Management dialog, accessible by selecting Manage Configurations from the Config menu, enables you to store and reload copies of an entire configuration, which can be an easy way to switch between setups for different tasks or work environments. You can also restore Smaart to its first-run defaults at any time by simply clicking the Restore Defaults button in the Manage Configurations dialog. This can be useful as a “panic button” when you are learning to use the program or as a quick way to clear the board for a new project.
The first time you run Smaart, it will create a folder with the same name as the your version of Smaart in the Documents directory for your user account to hold its data files. Configurations are stored as XML files in the Config subdirectory of your Smaart data folder. Copies of config file(s) for a given computer can be saved to any other location for backup purposes, however we do not recommend attempting to move them from one machine to another, due to environment-specific information they contain. The current configuration is stored in a file named Config.xml. If you delete this file while Smaart is closed, it will have the same effect as doing running Restore Defaults from the configuration manager.
Storing & Recalling Configurations
To store a copy of your current configuration to a file that you can reload at some later time, open the Manage Configurations dialog and click the Save As button in the Current Config section. You will be prompted to name the stored configuration. When you have done so, click OK to close the pop-up window and your new configuration will appear in the Stored Configs list.
Each saved config file is a “snapshot” of your configuration’s state at the moment it was saved. Modifications to Smaart's current configuration made after the file was saved will not affect settings in the saved copy. You can, however, overwrite an existing configuration with current settings by selecting its name in the list and clicking the Overwrite button. To rename an existing configuration, double-click its name in the list to make it editable, type in the new name, then press the [Enter] key on your keyboard to set the change.
To load a stored configuration, click its name in the list to select it and then click the Recall button. Smaart will warn that you are about wipe out all of your current settings and ask if you are sure that’s what you want to do. Assuming that you say yes, Smaart will close the current windows and reopen them to the configuration that you selected on restart.
To make a copy of a stored configuration select its name and click the Copy button. Here again, you will be prompted to name the new config file.
To delete a stored configuration that you no longer need, select its name and click the Delete button.
Config files do not include measurement data files or their display settings, and so changing configurations does not affect your stored data. Smaart measurement data files reside in the Data directory of your Smaart data folder and are managed through the Data Bar. Reloading a stored configuration will not restore files that have been deleted since the config file was saved, nor will reloading a configuration delete any new files created after the config file was written.
The configuration does remember display settings for some types of data files (depending on your Smaart product type) that were present when the config file was saved, including show/hide state, y-axis offset, weighting, and the state of the Inverted check box (for Transfer Function traces).