--- title: "Magnitude Response" slug: "magnitude-response" status: "update" updated: 2026-10-28T18:40:04Z published: 2026-10-28T18:40:04Z canonical: "doc360.rationalacoustics.com/magnitude-response" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Magnitude Response The Transfer Function Magnitude plot shows both the magnitude portion of the frequency response of the system under test (SUT) and [coherence](/v1/docs/coherence) for the active transfer function measurement. The magnitude plot shows relative gain and Attenuation in the output of the system at each frequency. If the reference and measurement signals are identical in level at all frequencies, the magnitude trace is a flat line at 0 dB. If there is an overall level difference between the two signals, the centerline of the measurement moves up or down on the graph – up means the measurement Signal is coming in at a higher level, relative to the reference signal, down means the reverse is true. If the SUT produces a relative gain at some frequencies and relative attenuation at others (as is usually the case with real world sound systems), the magnitude trace will deviate above the centerline of the measurement at frequencies where there is a relative gain and dip below it in regions of attenuation. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-12 at 14-09-10.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=SNrfLJaSlvPlhC9NAnDCyc33CUgZXfgi9RXhNac5Pdg%3D) *Transfer Function Magnitude plot.* Because we are directly comparing the signal going into the SUT to the output signal that the system produces in response, we get the same response curve using virtually any broadband signal with sufficient energy at all frequencies to resolve the measurement (including music). Unlike Spectrum measurements, the shape of the response curve is not dependent on the spectrum of the input signal. The resulting magnitude response ends up looking very similar to a fractional octave spectrum measurement made using Pink Noise, particularly when *Polar* averaging is used. When *Complex* magnitude averaging is selected, RTA and transfer function magnitude measurements of the same system *can* look significantly different in some cases, owing to the tendency for complex averaging to reject reverberation as “noise.“ When running multiple live transfer function measurements it is a good practice to match the sensitivity of each measurement so that that their overall magnitude levels match. This makes the overall levels of each measurement directly comparable to each other and directly relatable to relative sound pressure level. A straightforward method for sensitivity matching is to measure the same source from exactly the same position with each microphone, adjust their levels to match in that position and then don’t touch the preamp settings afterward. Of course, no two microphones have identical frequency response but any mic that bills itself as a measurement microphone should have very nearly flat response up to 10-12 kHz at least, so that is generally the range that you want to concentrate on most. Note that sensitivity matching is not the same thing as sound level calibration. You could however, accomplish the more or less the same result using a sound level calibrator, by adjusting the input gains for each microphone to get the same full-scale for each. In that case, the calibration offset for SPL measurement would end up being the same for each microphone. The Transfer Function Magnitude plot shows both the magnitude portion of the frequency response of the system under test (SUT) and [coherence](/v1/docs/coherence) for the active transfer function measurement. The magnitude plot shows relative gain and Attenuation in the output of the system at each frequency. If the reference and measurement signals are identical in level at all frequencies, the magnitude trace is a flat line at 0 dB. If there is an overall level difference between the two signals, the centerline of the measurement moves up or down on the graph – up means the measurement Signal is coming in at a higher level, relative to the reference signal, down means the reverse is true. If the SUT produces a relative gain at some frequencies and relative attenuation at others (as is usually the case with real world sound systems), the magnitude trace will deviate above the centerline of the measurement at frequencies where there is a relative gain and dip below it in regions of attenuation. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot 2026-06-12 at 14-09-10.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=SNrfLJaSlvPlhC9NAnDCyc33CUgZXfgi9RXhNac5Pdg%3D) *Transfer Function Magnitude plot.* Because we are directly comparing the signal going into the SUT to the output signal that the system produces in response, we get the same response curve using virtually any broadband signal with sufficient energy at all frequencies to resolve the measurement (including music). Unlike Spectrum measurements, the shape of the response curve is not dependent on the spectrum of the input signal. The resulting magnitude response ends up looking very similar to a fractional octave spectrum measurement made using Pink Noise, particularly when *Polar* averaging is used. When *Complex* magnitude averaging is selected, RTA and transfer function magnitude measurements of the same system *can* look significantly different in some cases, owing to the tendency for complex averaging to reject reverberation as “noise.“ When running multiple live transfer function measurements it is a good practice to match the sensitivity of each measurement so that that their overall magnitude levels match. This makes the overall levels of each measurement directly comparable to each other and directly relatable to relative sound pressure level. A straightforward method for sensitivity matching is to measure the same source from exactly the same position with each microphone, adjust their levels to match in that position and then don’t touch the preamp settings afterward. Of course, no two microphones have identical frequency response but any mic that bills itself as a measurement microphone should have very nearly flat response up to 10-12 kHz at least, so that is generally the range that you want to concentrate on most. Note that sensitivity matching is not the same thing as sound level calibration. You could however, accomplish the more or less the same result using a sound level calibrator, by adjusting the input gains for each microphone to get the same full-scale for each. In that case, the calibration offset for SPL measurement would end up being the same for each microphone. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. A decrease in the level of a signal. Attenuation can refer to reduction in level for a specified frequency range or a decrease in the overall level. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. The frequency content of a given signal. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy. The Real-Time Analyzer (RTA) enables you to look at the frequency content of signals moment-by-moment in real time. The RTA is a graph of the energy in an incoming signal, broken down by frequency or frequency ranges, with frequency (in Hertz) on the x axis and magnitude (energy) on the y axis in decibels (dB)