--- title: "IR Mode Data Bar and Trace Info" slug: "ir-mode-data-bar-and-trace-info" status: "new" updated: 2026-10-29T19:54:05Z published: 2026-10-29T19:54:05Z canonical: "doc360.rationalacoustics.com/ir-mode-data-bar-and-trace-info" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # IR Mode Data Bar and Trace Info The Data Bar in Impulse Response mode works almost exactly like [the Data Bar in real-time mode](/v1/docs/the-data-bar-1) but with a few exceptions. Here we have only one data file type to contend with – IR measurements, which are stored as .wav files. IR Mode’s Data Bar menu commands are a subset of the [Real Time mode Data Bar menu commands](/v1/docs/data-bar-menus). Menu commands that are not applicable to impulse response data are simply greyed out, as shown below: ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(640).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A13Z&se=2026-11-18T18%3A30%3A13Z&sr=b&sp=r&sig=rMJPzYtCSWkBas310dKJRq2orwGqFOYmtMCNGNMlT30%3D) Smaart can read standard .wav files from almost any source, but IR measurements created in Smaart have extended information stored in the .wav file headers that tell us some things we would not know otherwise. These attributes can be viewed in the *Trace Info* dialog, which is generally a subset of the Real-Time mode Trace Info dialog with a single exception: the inclusion of an *Import* button. The *Import* button will import [decay marker positions](/v1/docs/rt60-level-markers) used to calculate [RT60 reverberation times](/v1/docs/reverberation-time). Smaart can also store user-selected decay marker positions in the header of IR .wav files. Previous versions of Smaart (optionally) stored these coordinates in separate companion files in comma-separated values (.csv) format, requiring you to import the marker position file each time you loaded the .wav file. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/Screenshot%202026-07-16%20at%2015-31-22.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A13Z&se=2026-11-18T18%3A30%3A13Z&sr=b&sp=r&sig=Jr8CjCwAbAYzRh8q2vEiaUSraeZ1RbEsPPp1v%2B0Dg3I%3D) > **To write decay marker positions from an external .csv file to the header of a legacy IR data file, click the *Import* button in *Trace Info*, navigate to the location of the maker position file and open it, then click the *OK* button in the *Trace Info* dialog.** The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function.