--- title: "IR Mode Control Bar GUI" slug: "ir-mode-control-bar-gui" updated: 2026-09-18T20:29:08Z published: 2026-09-18T20:29:08Z canonical: "doc360.rationalacoustics.com/ir-mode-control-bar-gui" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # IR Mode Control Bar GUI ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(35).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T18%3A30%3A08Z&sr=b&sp=r&sig=XlY1k63vCw92PmgFAPhG52poVxGimrC6INvmw18wB0w%3D) *IR Mode Control Bar.* The Control Bar in Impulse Response mode is home to the in-tab SPL meter/Clock and includes live measurement controls, bandpass filters Signal generator and main display controls. The Control Bar and in-tab [SPL Meter](/v1/docs/template-1) (when present) can be shown or hidden by pressing the [O] key on your keyboard or selecting *Control Bar* from the [*View* menu](/v1/docs/view-menu). When hidden, a triangular button appears in the right border of the window and clicking this button will restore it. The in-tab SPL Meter/Clock can be hidden independently of the Control Bar. You can also change it to a clock by pressing the [K] key on your keyboard or selecting *Toggle SPL/Clock* from the *View* menu. To hide this display completely, use the *SPL Meter* command in the *View* menu or press [Alt/Option] + [K] on your keyboard. For more information about the in-tab SPL Meter/Clock, please refer to the [*SPL Meter/Clock*](/v1/docs/template-1) article. --- ## Live Measurement Controls The next section below the SPL Meter/Clock houses live measurement controls for recording impulse response measurements in the field. Note that you can also analyze file-based data in impulse response mode. --- ## Dual-Channel Measurement Settings The FFT size and averaging (Avg) controls together determine the measurement duration for dual-channel impulse response (IR) measurements. Notice that for each FFT size, the Time Constant is given along with the FFT size in samples. The FFT time constant, also called the measurement "Time Window," is the amount time it takes to record the required number of samples for a single FFT frame at the currently selected Sample Rate. The Averages (Avg) selector sets the number of successive IR measurements to average together to improve the signal-to-noise ratio of dual-channel measurements. When measuring with random signals or in noisy environments, more averaging can significantly improve the signal-to-noise ratio of impulse response measurements. For deterministic IR measurements made using period-matched signals, the number of averages is normally set to a low number or even “None”. Note that overlapping successive measurements (by setting Overlap *%* in the *General Options* section of *Impulse Response Options* to a number greater than 0) will generally reduce the noise reduction benefit of any given number of averages. --- ## IR Measurement Controls The row of buttons below the FFT size and Averaging selectors control the capture of new IR measurements and determine their type. The button labeled with a circle (●) works like the record button on a tape deck or digital recorder, but in this case, it is a measurement type control. Clicking the run/stop (►) button (or use the hot key [Shift] + [R]) **without** the record button punched in triggers a dual-channel IR measurement using both input channels of each selected "measurement engine" (see below). Smaart records the specified number of FFT frames at the selected FFT size for each selected measurement pair and then calculates and displays the results when finished. Clicking the run/stop (►) button while the measurement procedure is running cancels the measurement. The button labeled with the hammer and wrench icon opens the *Measurement Config* page. With the record button (●) activated, Smaart becomes a single-channel digital recorder and records just the measurement signal channel(s) of selected measurement engine signal pairs. The idea is that you would start the recording and pop a balloon or fire your starter pistol (or whatever), and then click the run/stop (►) button again to end recording and display the results. The Continuous (*Cont*) button causes dual-channel measurements to run continuously, starting over again automatically each time it finishes a measurement until you tell it to stop (by clicking the stop button). The results of the last measurement are displayed while it’s recording and processing the next measurement. Click the run/stop (►) button again to stop the measurement. --- ## Measurement Engines Dual-channel IR measurements in Smaart are essentially Transfer Function measurements (followed by an inverse Fourier transform) and so any of the transfer function signal pairs that you have set up in the current tab for real-time (frequency-Domain) transfer function measurements may also be used in any combination for IR measurements. The check box in the upper right corner of each measurement engine's control block determines whether or not it is included when capturing a new IR measurement – if left unselected, the measurement engine is ignored. After capturing a new IR, clicking the circular button to the right of the delay field in any active (checked) measurement control block sets its delay time to the highest peak found in the new measurement. Note that new IR measurements are initially stored only in memory. Any previous unsaved measurement data captured for selected measurement engines is replaced by new date when you run a new measurement. To save new measurements to .wav files, click the Save or Save All buttons on the Data Bar. The "*+ TF Engine* button below the live measurement control blocks does the same thing as the *New TF* commands in the *Config* menu. Creating a new transfer function measurement engine also creates a new Impulse Response mode measurement engine to match. The *View* button opens a menu for selecting *View Presets*, which also includes main display control buttons for allocating the main graph area (à la Smaart 7 and 8, in case anyone misses them), show/hide buttons for the Data Bar, Tab Bar, Control Bar, and Command Bar, and a *Tab* selector drop list in case the tab bar is hidden. The Timer button opens the settings page for timed measurements however timed measurements are currently not available in Impulse Response mode. --- ## Bandpass Filters ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(36).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T18%3A30%3A08Z&sr=b&sp=r&sig=t8%2BHyaK8jUbqoHuQwO%2BaLlhYIeaXcrga%2FLS%2FwLMBvPk%3D)The broadband impulse response is useful for finding delay times and discrete reflections, but for most acoustical analysis purposes, the IR needs to be filtered into octave bands or sometimes 1/3-octave bands. Smaart includes complete sets of octave and 1/3-octave bandpass filters for impulse response analysis. Bandpass filtering is non-destructive and is done on the fly whenever you need it. All you have to do is select the filter set that you want to use (Octave or 1/3-Octave) using the *Filters* selector on the Control Bar and then choose the center frequency for the band that you want to analyze from the *Band* list. Smaart's octave and 1/3-octave band filters are linear Phase with Magnitude response conforming to IEC 61260-1:2014 Class 1 specifications. In addition to the conventional octave and 1/3-octave bandpass filter, there is a user-defined bandpass filter option. When selected, a pair of input fields appear to specify cut-off frequencies for the high-pass and low-pass filter. These are the same filters that can optionally used for band-limiting the broadband IR (see *Impulse Response Options*) but settings for the user-defined bandpass filter are maintained separately. The high pass and low pass filter have linear phase response and are designed to approximate 6th-order Butterworth magnitude response in the pass band but have steeper roll-off in the transition band. The low-pass filter is based on a bi-linear transform design and will effectively increase in order at frequencies approaching Nyquist. The minimum bandwidth for the user-defined filter is one octave. When the high-pass and low-pass filter cut-off frequencies are set exactly one octave apart they form a bandpass filter conforming to EC 61260-1:2014 Class 2 magnitude response specifications. --- ## Signal Generator Controls ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(37).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A08Z&se=2026-11-18T18%3A30%3A08Z&sr=b&sp=r&sig=KMkPtu3tldOBI%2Fd2TFT2L0fHnlV3sBMINmYbiSYy6f4%3D)The next group of controls on the Control Bar is for the signal generator. The label at the top of this section is actually a hover button (it turns into a button when your mouse cursor passes over it) that opens the *Signal Generator* dialog, which contains a lot more options for the signal generator than we could fit on the Control Bar. Below are a signal type selector (Pink Noise is selected in the example to the right) and an output level field that shows the current output level in normalized dB Full Scale. The On button turns the generator on or off – it glows an angry red when the generator is running. The minus and plus (−|+) buttons to the right of the output level field bump the signal level down or up by 1 dB. --- ## Display Controls The last group of controls consists of six buttons. - The *All Bands* button opens the *All Bands* table, where you will find nearly all of the quantitative acoustical metrics that Smaart can calculate automatically for an impulse response. See [*Histogram* and *All Bands Table*](/v1/docs/template-1-1) for more in this feature. - Clicking the T60 button displays level marker widgets used for calculating Reverberation Time and early decay time on Log IR or ETC plots. - The *Schroeder* button displays a reverse time integration curve on Log IR or ETC plots. To exit Impulse Response mode, click either the Real-Time or SPL mode selector buttons above the control bar. The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant. The number of times that the amplitude of a signal is measured within a given period of time in analog-to-digital conversion. For audio-frequency signals, sampling rate is typically expressed in samples/second or Hertz. For Smaart’s purposes, the term Overlap refers to the amount of data each successive FFT Frame shares in common with the one before. Overlapping FFT frames are analogous to shingles on a roof. When no overlap is used, each new FFT frame begins where the last one stopped, as beads on a string. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy. The term full scale (FS) has two possible meanings in digital signal processing. Normalized full scale refers to the maximum amplitude of a digital signal sampled at a given integer sample word size (bits per sample), scaled to +/- 1.0, such that 0 dB corresponds to the maximum possible peak signal value and all lesser decibel values are negative. A second convention preferred by the Audio Engineering Society (AES) references 0 dB to the RMS value of a full-scale peak-to-peak sinewave (i.e., 0.7071 rather than 1.0). In Smaart, all FS decibel values are referenced to normalized full scale, meaning that the RMS power of a full scale sinewave is -3.01 dB. When using a linear amplitude scale, Full Scale amplitude values are typically given as percentages, where 100% = 1. In acoustics, the amount of time required for audio energy introduced into a system (typically a room) to diminish, or decay by 60 decibels following the cessation of a stimulus signal used to excite the system — e.g., a balloon pop, gun shot or terminated pink noise. It is normally stated band-by-band for individual octave bands. By convention, decay times are normalized to the time required for 60 dB of decay at an observed rate of decay, regardless of the amplitude range actually measured. 60 dB decay time is often referred to as “RT60” or “T60", which is sometimes a source of confusion. And just to confuse things a little more ISO 3382 specifies that it should be called T20 or T30, where the “20" and “30” refer to the decay range actually measured. The main thing to remember is that all of the above refer to 60 dB decay time within a stated frequency range. When a single-number reverberation time is given, according to the ISO standard it should be the average of the reverberation