--- title: "Input Meters Window" slug: "input-meters-window" updated: 2026-04-15T18:22:19Z published: 2026-04-15T18:22:19Z canonical: "doc360.rationalacoustics.com/input-meters-window" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Input Meters Window The Input Meters window displays a graphical, peak-reading signal level meter calibrated to normalized full scale for each input channel that is currently selected for use in Smaart on the [*I-O Config*](/v1/docs/io-config) tab of the Configurator dialog. This window is accessible by selecting Input *Meters > Input Meters Window* from the [*View* menu](/v1/docs/view-menu) or pressing [Shift] + [E] on your keyboard. Repeating either of the actions while the window is open will close it. | ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(17).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A03Z&se=2026-11-18T18%3A30%3A03Z&sr=b&sp=r&sig=R31RqPb8nHS5pjQ7H5thjC6c3PGE8cCjOup0iIz%2B0cg%3D) *Horizontal Meter Orientation* | ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(18).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A03Z&se=2026-11-18T18%3A30%3A03Z&sr=b&sp=r&sig=gu9KdQ9iXD6kuA5SkN04TWn5BzNmWpZropBphNDhWdk%3D) *Vertical Meter Orientation* | | --- | --- | The meter window is resizable, the component meter modules scale with window size, meaning that you can expand the window to display larger meters or shrink the window and all of its contents to take up less space or fit more meters on your screen. You also have the option of a horizontal or vertical window layout. To change the orientation of the Input Meters window, you can select *Input Meter > Input Meters* *Orientation* from the *View* menu or press [Alt/Option] + [Shift] + [E] on your keyboard. Repeating either action will change it back. The individual level meters that make up the *Input Meters* window are multicolor, with each color representing a specific Amplitude range. Signal levels below -60 dB FS Peak are shown in dark green, transitioning to lighter green from -60 to -12 dB, then yellow from -12 and -6 dB and red above -6. Since the meters are calibrated to normalized full scale peak, the maximum possible value is 0 dB. If a clip is detected on any input channel, its entire meter bar turns red until the condition is resolved. Each meter module includes a polarity invert button (useful if you have a microphone that's wired Pin 3 +). Level meters for input channels on supported devices may also include input gain and 48V phantom power controls. Note: The invert button for 10Eazy devices are disabled since the microphone is known. Smaart v9 currently supports the below devices for gain and phantom power control: As of Smaart v9.6 there are three types of I-O Device that support direct Smaart integration: - [Audient EVO 4, 8, & 16 (v9.1 or later. Audient EVO SP8 is not supported)](/v1/docs/audient-evo-control-integration) - [Roland Octa-capture (Smaart v8 or later. These devices are discontinued)](/v1/docs/roland-octa-capture-control-integration) - Smaart IO (Smaart v8 or later. These devices are discontinued) In signal processing, the maximum deviation from zero in an alternating signal in either the positive or negative direction, typically expressed in volts for an electrical signal, or as a fractional quantity or percentage of Full Scale, in the case of digital signal.