--- title: "IR Measurement Guide, Part 2: Inside Smaart" slug: "how-to-perform-an-ir-measurement-part-2-in-smaart" updated: 2026-09-02T20:51:54Z published: 2026-09-02T20:51:54Z canonical: "doc360.rationalacoustics.com/how-to-perform-an-ir-measurement-part-2-in-smaart" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # IR Measurement Guide, Part 2: Inside Smaart Once you have [determined your source and measurement positions and chosen a measurement technique](/v1/docs/how-to-perform-an-ir-measurement), Smaart's involvement is quite straightforward. It follows these basic steps: 1. Select your measurement parameters, including: - Input source - Excitation level - Measurement duration (Time Window) - FFT Size - Averaging & Overlap - Delay compensation 1. Turn on the Signal generator or other stimulus signal source. 2. Start the measurement and save it. From this point, you are free to analyze the Impulse Response data you've collected. [A list of common IR measurement settings can be viewed here](/v1/docs/common-ir-measurement-settings). The following guide includes a more detailed guide to each setting as well as how to make and save the measurement in Smaart. --- ## IR Measurement Settings in Smaart The two main things you need to concern yourself with at this point are stimulus **excitation level** and **measurement duration**, which are determined by a combination of **FFT size** and the **number of averages**. ### Excitation Level As a starting point, it is recommended that you measure your background noise level. Your excitation level will be set in relation to this baseline. Since this level is used to set a relative threshold, precise SPL calibration isn't necessary ([unless measuring STI](/v1/docs/calculating-sti)). To do so, set the sound level meter in Smaart to "Slow SPL" and let the meter run for 10-20 seconds with no output signal running. This will give you a general idea of the background noise level, against which to set your excitation level. Then, start the signal generator at a low level and gradually increase the gain until you reach your target level (or as close as possible). Ideally, your excitation level should be at least 40-50 dB higher than your background noise level. In Reverberation Time (RT60) measurements, reverberant decay is over a range. This range starts 5 dB below the arrival of direct sound (typically the highest peak on the plot) and extending down another 20 or 30 dB from the start point (while a 30 dB range is preferred, 20 dB is also acceptable). The lower end of the range should be at least 10 dB above the measured noise floor. Following these guidelines, you should see a minimum of 45 dB of Dynamic Range for a 30 dB evaluation range, or at least 35 dB for a 20 dB range (in an ideal situation with no noise artifacts from the measurement process itself). In more realistic situations, adding another 5 to 10 dB on is advantageous (so long as it doesn't drive the system into distortion or cause damage). ### Measurement Duration (Time Window) and FFT Size For dual-channel measurements, the **time window** (measurement duration) is determined by the FFT Time Constant - that is, the time required to record enough samples for a given FFT size at whatever Sample Rate you are using. In Impulse Response mode, Smaart gives you the time constant in milliseconds, along with the frame size in samples for each available FFT/DFT size. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(600).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A19Z&se=2026-11-18T18%3A30%3A19Z&sr=b&sp=r&sig=n53lL%2F7%2F4nAz7pYaCt%2FJtebmrVbkQ%2FA0y0DOYn000%2Fk%3D) If you are measuring: - **Delay times only:** - The measurement should be 3 times the longest delay time you want to measure. - **Reverberation time *and* early-to-late energy ratios:** - The 60 dB decay time (RT60) of the system is a good target. This is not only a requirement for period-matched/dual-channel measurements, but a good general guideline in general. Ideally, you would like to measure 30 dB of reverberant decay with the lower end of the evaluation range +10 dB above the noise floor, which would be 40 dB (2/3 of 60). By the time you factor in Propagation Delay, early decay and maybe enough of a noise tail to see the dynamic range of the measurement, chances are you have eaten well into the remaining third. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(601).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A19Z&se=2026-11-18T18%3A30%3A19Z&sr=b&sp=r&sig=MsuuOS03jElyDOV0vDU5RqncyGefldePALTVJeuqots%3D) Both rules require either knowing either the [delay time](/v1/docs/delay-compensation) or [RT60](/v1/docs/reverberation-time) before measuring, however. This typically means you need to guess, then measure, then possibly adjust and measure again. For delay times, you can divide the distance to the source by the Speed of Sound, to start. The speed of sound, 1130ft/sec (345m/sec) at typical room temperatures, increases with temperature, so you may need to adjust this value if measuring a particularly hot or cold room. For reverberation times, one to two seconds is a useful starting point for most theaters/auditoriums. Indoor stadiums and other large structures tend to have much longer reverb times. You may want to make longer measurements then you think you might need, as there is no downside to do so. Lower frequencies tend to decay more slowly than highs, so lower octave decay time is the key deciding factor in measurement length. ### Averaging and Overlap **Averaging** is remarkably more effective when using random stimulus signals. With random (or effectively random) signals, typical averaging settings are in the 4-16 range. Noisier environments may require a larger value (or just resorting to using a period-matched signal). When measuring with period-matched noise or sweeps, averaging is normally set to "None" or 2, although it is still possible that a higher setting could prove helpful if measuring in an extremely noisy environment. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(602).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A19Z&se=2026-11-18T18%3A30%3A19Z&sr=b&sp=r&sig=bU%2FCVH4LezW4CwsG3JhWt7sXoQnKsPGuxSL%2Fr3rsqm8%3D) The **Overlap** setting also affects averaging and can be adjusted in the *Impulse Response Graph Options* menu (accessible by either the [Alt/Opt] + [i] hotkey or by navigating to *Options>Graph Settings>Impulse Response*). When set to **0%**, each FFT is calculated from unique data for maximum noise reduction in that averaging setting. When set to a **non-zero** **value**, some data carries over to successive FFTs, similar to Spectrograph overlap. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(603).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A19Z&se=2026-11-18T18%3A30%3A19Z&sr=b&sp=r&sig=kTYftVhsDO0CXsJq5zTGaUvZyJLvHg0t9PakgwyZXcU%3D) If overlap is set to **50%**, it takes slightly longer to record 16 averages than it would for 8 at 0% overlap. You don't get the full benefit of averaging 16 unique FFTs in that case (with increased processing time) but you *will* experience better signal-to-noise than you would get 8 with some net time savings. ### Delay Compensation When using random signal sources your results will improve if you compensate for the delay time through the SUT. It is typical to measure twice if the delay time isn't already known: once to find the delay and a second time utilizing the delay. Clicking the circular gray button to the right of the delay field in the measurement engine control block sets reference signal delay to the highest peak in the impulse response. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(604).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A19Z&se=2026-11-18T18%3A30%3A19Z&sr=b&sp=r&sig=fK21UAeFEgSnwSxyV%2Fz8zvORKXKtEhj7QvAhym10F0I%3D) > **Note: Setting the delay to a non-zero value does not affect the peak location in the resulting IR. Smaart will apply delay compensation while making the IR measurement and then back out the delay time upon completion. This preserves the flight time for direct sound in the time record.** --- ## Finally Making the Measurement At this point, all of the groundwork has been laid out. Outside of Smaart you've chosen your measurement technique, excitation sources, and measurement positions. Within Smaart, you've set your input/output levels, FFT length, and number of averages, if applicable. All that's left is to take the measurement itself. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(605).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A19Z&se=2026-11-18T18%3A30%3A19Z&sr=b&sp=r&sig=pXlvUtQTn4xnzZbXUcu15iL91CtOjy4c%2B2MBGcWQupg%3D) - For a **dual-channel (indirect IR)** measurement: - Start your excitation signal (unless using a triggered sweep, in which case the generator will start automatically when you start the measurement). - Click the start (play) button at the top of the Control Bar. - Smaart take the measurement and display the results when complete. - For a **single-channel (direct IR)** measurement: - Click the record button. - Click the start (play) button. - Trigger your excitation source (pop your balloon/fire your blank pistol/etc.) - Give the system a moment to ring out. - Click the stop button to end the recording and display the results. --- ## Saving Your Work When you make a new IR measurement, it is not saved automatically. Since you may need to make several IR measurements while adjusting your settings, this would create unnecessary data bar clutter. To save your measurement either press [Space] or click the Save button on the Data Bar. Doing so will only save the top trace. You will then be prompted to name your measurement. When you click *OK* on the *Save Trace* dialog, the new file will immediately appear in the current session folder in the Data Bar. **If you have cropped the file for display purposes using the Crop function, only the displayed portion of the time record is written to file.** Additionally, you can save *all* displayed measurements by using the shortcut [Shift] + [Space] or by clicking the *Save All* button on the Data Bar. In this case, you will be prompted to name the destination folder and each measurement will be saved there as their measurement engine names. The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant. For Smaart’s purposes, the term Overlap refers to the amount of data each successive FFT Frame shares in common with the one before. Overlapping FFT frames are analogous to shingles on a roof. When no overlap is used, each new FFT frame begins where the last one stopped, as beads on a string. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. In acoustics, the amount of time required for audio energy introduced into a system (typically a room) to diminish, or decay by 60 decibels following the cessation of a stimulus signal used to excite the system — e.g., a balloon pop, gun shot or terminated pink noise. It is normally stated band-by-band for individual octave bands. By convention, decay times are normalized to the time required for 60 dB of decay at an observed rate of decay, regardless of the amplitude range actually measured. 60 dB decay time is often referred to as “RT60” or “T60", which is sometimes a source of confusion. And just to confuse things a little more ISO 3382 specifies that it should be called T20 or T30, where the “20" and “30” refer to the decay range actually measured. The main thing to remember is that all of the above refer to 60 dB decay time within a stated frequency range. When a single-number reverberation time is given, according to the ISO standard it should be the average of the reverberation The difference in level between the highest and lowest signal a system can accept or reproduce, for example the range between the noise floor and the clipping voltage of an amplifier, typically expressed in decibels. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. The number of times that the amplitude of a signal is measured within a given period of time in analog-to-digital conversion. For audio-frequency signals, sampling rate is typically expressed in samples/second or Hertz. The time it takes for sound to travel from one place (such as a loudspeaker) to another place (e.g., a measurement microphone). The speed at which sound waves propagate through a transmission medium such as air or water. This quantity has dependent actors such as temperature and density of the material of propagation. Useful rule-of thumb values for the speed of sound in air at room temperature are 1130 ft/sec, or 344 m/sec. In Smaart the speed of sound is used primarily to calculate distance equivalents for time differences. A three-dimensional data plot, displayed in two dimensions with color representing the third dimension (or z-axis). The spectrograph is a topographical representation of the once-common waterfall display.