--- title: "Histogram Display" slug: "histogram-display" updated: 2026-06-08T18:10:22Z published: 2026-06-08T18:10:22Z canonical: "doc360.rationalacoustics.com/histogram-display" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Histogram Display Selecting *Histogram* as your display type for an IR mode graph plots a chart of all reverberation times or early-to-late energy ratios by either octave or 1/3-octave bands. The type of data the *Histogram* displays and the resolution are selected by means of the list control in the upper left corner of the graph. You can change the Histogram to a line chart by opening *Graph Settings >* *Impulse Response* and selecting *Lines* under *Histogram Settings*. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(43).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A42%3A06Z&se=2026-11-18T18%3A42%3A06Z&sr=b&sp=r&sig=2tnVEtt8Jq1kM22mxTlTcewBG26zvCZ7DBltyQa%2FR2I%3D) *Smaart’s Histogram plot and All Bands Table.* The [*All Bands* Table](/v1/docs/all-bands-table) in Smaart collects [reverberation times](/v1/docs/reverberation-time) and early-to-late energy ratios for all octave and 1/3-octave bands in a single table. [Speech intelligibility metrics (STI and STIPA](/v1/docs/sti-stipa)) are displayed here as well. The *Histogram* chart can plot any column of the *All Bands* Table as a bar graph or line chart in octave or 1/3-octave resolution. The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. (STI for public address systems) is a less rigorous variant of STI (see above) intended specifically for use in measuring public address systems. STIPA has been validated only for male speech. The only functional difference in how STI and STIPA are measured is that instead of evaluating 13 modulation frequencies in each octave band, STIPA uses only two frequencies per band to cut down the time required for direct measurement of the modulation transfer functions (MTF). Since Smaart calculates the MTF of a system indirectly from its impulse response and all 13 modulation frequencies required for STI are also used for STIPA (just not in every band) there is no particular advantage to using STIPA in Smaart