Which audio interface should I use with Smaart?

While Rational Acoustics does not officially endorse one particular audio interface to use with Smaart. Smaart will work with any I-O device that uses WAV/WDM (Windows), ASIO (Windows) or CoreAudio (macOS) device drivers. As long as there are standardized drivers compatible with the OS version you are running, it should work properly. It is ultimately up to the hardware manufacturer to ensure that the device is compatible with the most recent version of macOS or Windows. Please make sure to check manufacturer websites prior to purchase.

Which interface is best for your situation is dependent upon a number of factors such as channel count, software integration, and network capabilities. Smaart does have gain control and tracking integration on a number of devices.

Purchase recommendations can be made by our support team on a case-by-case basis. Please submit a ticket to reach us.

Which interfaces have control integration and gain tracking in Smaart?

Smaart can control the gain and phantom power of certain audio devices directly from its input meters, accessed by navigating to View > Input Meters or use the [Shift] + [E] hot key.

Devices with control integration will also allow for gain tracking, which is enabled in the Input tab of the I-O Config window. To turn on this feature, check the "Gain Tracking" box after calibrating your input for SPL. This will cause Smaart to recalculate its dB offset with the gain for any calibrated channel of that device is adjusted. Please note that this recalibration is not perfect, so you might see a +/- 1dB difference depending on how large the gain change is.

The following devices have gain tracking integration in Smaart.

Which microphone(s) should I use with Smaart?

Determining what measurement microphone to use primarily depends on the types of measurements you will be making, and of course - your budget.

For basic measurement scenarios, we do not recommend one measurement microphone over another. Any Omni-directional, flat frequency response measurement microphone should do the trick.

If you are measuring SPL, there are some additional considerations. See the Selecting Hardware for SPL measurement article for more information.

Purchase recommendations can be made by our support team on a case-by-case basis. Please submit a ticket to reach us.

My RTA-420 is Pin-3 Hot, what does that mean?

The Rational Acoustics RTA 420 is Pin 3 hot. This means that the polarity of the microphone is reversed compared to most other microphones.

If you are using a single microphone, or all of your microphones are Pin 3 hot, this should not affect your measurement.

If you will be comparing a standard (pin 2 hot) microphone to the RTA 420, this is something to be aware of. Polarity adjustment may be required.

Is the Smaart IO compatible with the Smaart v9 platform?

Yes, although it is now treated as a generic controllable interface like our other integrated audio devices such as the Roland Octacapture or Audient EVO series.

Gain control and phantom power can be natively controlled using the Smaart input meters (View > Input Meters, or the [Shift] + [E] hotkey.) Microphone sensitivity-based calibration and the saving of microphones is no longer supported. SPL calibration must be done manually using a calibrator such as the iSEMcon SC-1.

Gain tracking is still supported. For more information about gain tracking, click here.

Which wireless unit should I use for measurement?

There are many factors to consider when selecting hardware for wireless measurement (as discussed in this article). However, all considerations boil down to these two non-negotiable requirements:

  1. Linearity in Level - Frequency-shifting or gain effects are not desirable, as they will hurt coherence and alter the resulting measurement's response. When sending a Signal through an undamaged cable, it's perfectly reasonable to expect that its output is at a similar level, with a largely untouched frequency response. The same should be true of any useful wireless unit, but this is not always the case. Many wireless units make use of companding, which can negatively affect linearity beyond the point of usefulness. Companding and its effects are described in greater detail in the article linked above.

  2. Time Invariance - Any time-variant phenomena must be avoided. Linear delay values are integral for evaluating measurements (especially Phase), so any changes in timing between your measurement and reference signals will make your data unusable. For instance, if you capture a measurement through your wireless unit and find a delay value of 3.29 ms, then measure again without making any changes and see a delay of 3.52 ms, this variation in time can throw off your phase measurements. A guide on testing your wireless unit for time invariance can be found here.