--- title: "Frequency Domain Time Windowing (FTW)" slug: "frequency-domain-time-windowing" updated: 2026-09-18T20:49:52Z published: 2026-09-18T20:49:52Z canonical: "doc360.rationalacoustics.com/frequency-domain-time-windowing" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Frequency Domain Time Windowing (FTW) ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/base64-converted-image-1787339388231.png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=ng5aNj1MRt%2BPJFWHIc2DwLXabs17Z5CCUUcD0gdkoVY%3D)Frequency-Domain “time windowing” (FTW) is a complex linear smoothing technique performed in the frequency domain that is mathematically equivalent to applying a tapered window function to the Impulse Response in the time domain and transforming the result with a zero-padded FFT. Since the bandwidth of the smoothing kernel is linear, the effects of FTW are most noticeable at lower frequencies. Because complex data includes both the time (phase) and magnitude response of the system, FTW smoothing affects both traces simultaneously, without separate controls like you'd see with fractional octave smoothing. [For some general context, we have an article on Smoothing available here.](/v1/docs/smoothing-transfer-function) FTW is a global function applied to all live and captured Transfer Function measurements that use *Complex* Magnitude averaging (only). Enabling FTW forces the global magnitude averaging selection for live transfer function measurements to *Complex*. However, live measurements do not use the global setting and are unaffected by FTW if their magnitude averaging selection is *Polar*. Stored data traces captured using polar magnitude averaging are also unaffected. When FTW is turned on, a vertical red line appears on transfer function Magnitude and Phase graphs denoting the low-frequency cutoff for the equivalent Time Window. Because FTW limits the effective window size of the equivalent impulse response, data at frequencies below the cutoff frequency cannot be reliably resolved and should not be considered trustworthy. Impulse Response time-windowing is commonly used to 'clean up' measurements by eliminating reflections or later arriving energy from other sources. When a time-windowed IR is transformed into the frequency domain, some later-arriving noise and comb filter-causing reflections are "windowed" out of the frequency response. FTW Smoothing in Smaart emulates the frequency-domain resultant of IR time-windowing the IR in the time domain without requiring transforms back and forth between domains. --- ## Enabling FTW ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(429).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=8cE8P65uInVkcBZmXniEhqt9WFFtfqJPHgzzo6I93tQ%3D) *FTW smoothing must first be enabled in* *Options > Preferences > Advanced* *via the "Frequency Time Windowing (FTW)" checkbox.* FTW Smoothing is set in terms of equivalent nominal half-window length. Once enabled, two additional controls appear below the averaging control for transfer function measurements: A checkbox to turn FTW on and a text field to set the nominal time window size in milliseconds. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(430).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=q4OoAc%2BEJj9BzkNJPg0IYI6GtjwcB32cIBXlBfyGqPM%3D) Activating FTW will change the global Magnitude Averaging (Mag Avg Type) setting for TF measurements to "Complex". Additionally, it will smooth any measurement set to "Complex" locally along with any captured data traces that were captured while set to "Complex". ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(431).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=95EjPqbGDUhzxVWB0NinJvuWiUXvAmGXC%2FDUBBAIwTs%3D) --- ### Setting the FTW Smoothing Value FTW Smoothing is set in terms of nominal half-window length in milliseconds. The maximum half-window size is one half of the FFT Time Constant (TC = FFT Size / Sample Rate). It's generally more practical to stay below 25-30% of the FFT time constant, however. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(432).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A07Z&se=2026-11-18T18%3A30%3A07Z&sr=b&sp=r&sig=wDxMjbzqvSaUHOUhgXTmpvY5jwxEMMB%2BpGoYjYECVpU%3D) *When FTW is turned on, a vertical red line appears on transfer function magnitude and phase graphs indicating this threshold frequency, based on the current nominal time window setting.* Since FTW smoothing limits the effective time window of the measurement, the effective frequency resolution of the FTW-smoothed measurement depends on the nominal time window. For example, a 20ms FTW window size has an effective frequency resolution of 100Hz, regardless of FFT size. Data at frequencies below that point should be ignored, as they are below the first valid data point (100Hz). Smaart will indicate the lowest point for accurate frequency resolution via a vertical red line on each plot. In signal processing, the term “domain” refers to the independent variable of a signal. By convention, when graphing a signal the independent variable is typically placed on the horizontal (x) axis of the plot with the dependent variable on the vertical (y) axis. For example in Smaart, an impulse response display, with time (the independent variable) on the x axis and amplitude (the dependent variable) on the y-axis, is referred to as a time domain display. Similarly, Spectrum and Transfer Function displays where magnitude or phase shift are plotted as a function of frequency are called frequencydomain displays. Frequency-domain “time windowing” (FTW) is a complex linear smoothing technique performed in the frequency domain that is mathematically equivalent to applying a tapered window function to the Impulse Response in the time domain and transforming the result with a zero-padded FFT. In practice, FTW applies smoothing in the time domain, and can be a useful companion to frequency domain smoothing, especially when used with longer time values (50ms+). The signal that describes the response of a system to an ideal impulsive stimulus in the time domain. The impulse response of linear time invariant (LTI) system is the inverse Fourier transform of its frequency-domain transfer function. The frequency (magnitude and phase) response of a system, function or network. The transfer function of the linear time invariant (LTI) system can be measured directly, using techniques such as dual-FFT transfer function measurements that compare the output of the system to its input signal in the frequency domain, or by taking the Fourier transform of the system’s impulse response. 1. A number assigned to a quantity so that it may be compared with other quantities. 2. The absolute value of amplitude. As a convention, we most often use the terms amplitude to refer to linearly scaled quantities and magnitude when discussing amplitudes cast in logarithmic units such as decibels or orders of magnitude. Phase, or Phase shift is a timing difference in a signal (relative to some reference) at one or more frequencies, typically expressed in degrees, where 360° = one full cycle at a given frequency. The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant. In physics and engineering the term time constant is most commonly used to denote a time span between reference or threshold points in continuous processes, such as rise or decay time in the step response of filters, heating and cooling times in thermal systems and lag times in mechanical systems. In the context of acoustic measurement we typically use (or perhaps misuse) the term to mean the total time required for discrete processes, such as the time it takes to collect enough samples for an FFT and/or the time span of an impulse response measurement. This is to say that we tend to use the term interchangeably with Time Window. The number of times that the amplitude of a signal is measured within a given period of time in analog-to-digital conversion. For audio-frequency signals, sampling rate is typically expressed in samples/second or Hertz.