--- title: "Common IR Measurement Settings" slug: "common-ir-measurement-settings" updated: 2026-09-01T20:42:32Z published: 2026-09-01T20:42:32Z canonical: "doc360.rationalacoustics.com/common-ir-measurement-settings" --- > ## Documentation Index > Fetch the complete documentation index at: https://doc360.rationalacoustics.com/llms.txt > Use this file to discover all available pages before exploring further. # Common IR Measurement Settings Outlined in the the Smaart v8.5 User Guide, these are some common "go-to" settings for dual-channel IR measurements in Smart that generally work well for a variety of purposes. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(587).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A12Z&se=2026-11-18T18%3A30%3A12Z&sr=b&sp=r&sig=tZCHaCuyELLsB8jpLmKCt4jewAZXwVrM5C%2BHQfoin0g%3D) **1. Signal Type** If you are able to use Smaart's signal generator as your stimulus signal source, then period-matched pseudorandom noise is a good all-around choice for signal type. To turn on this option, open the signal generator control panel, select Pink Noise as the signal type, then tick the boxes labeled Pseudorandom and Drop IR Data Window. **2. Input Levels/Excitation Level** When using random or pseudorandom noise signals, -12 to -15 dB is a preferred input level for IR measurement in Smaart. If you need to measure Reverberation Time, then your excitation level should be at least 45 dB above the background noise level for T30 or at least 35 dB above to get T20. For most other purposes, any excitation level that is comfortable above the background level should be fine. **3. FFT Size and Averaging** 128K is a decent default setting for FFT size. At a 48k sampling rate, your Time Window will be almost 3 seconds. You'd need more than that in extremely large spaces, but it's a good fit for smaller venues. When using period-matched noise, an averaging setting of 2 is a good starting point. 8 is a good setting if you use a random signal source, and 16 is desirable if you are working in a noisier environment, with a 0% Overlap for averaging. **4. Delay Time** When using [period-matched noise](/v1/docs/synchronous-source-syncsource-measurements), a delay time of 0 is okay if it isn't already set. ![](https://cdn.document360.io/a725c8f7-3a1a-4c09-9518-5d15d09a2ae2/Images/Documentation/image(588).png?sv=2026-02-06&spr=https&st=2026-11-18T17%3A30%3A12Z&se=2026-11-18T18%3A30%3A12Z&sr=b&sp=r&sig=qScP3JsFToSb3RmCPU9xtR2rHt7kO06Coc2gLA1nqiE%3D) If you are using a **random noise** source and need to find your signal pair's delay time: - Run the IR measurement once to find the delay. - Click the circular gray button to the right of the delay field. - Run the measurement again. Strictly speaking a signal can be any set of values that depends on some other set of values. In signal processing, the independent variable, e.g., time or frequency, is said to be the domain of the signal. In audio and acoustics, the things we most commonly think of as signals are time domain signals, where voltages or numeric values representing amplitude (the dependent variable) vary over time (the independent variable). But by strict definition, most of the things we see in Smaart could also be called signals, including transfer function Magnitude and Phase and RTA displays where relative energy or phase shift are presented as a function of frequency, rather than time. A random (or pseudorandom) signal in which, over a given averaging period, each Octaveband (or other logarithmically spaced interval) contains an equal amount of energy. In acoustics, the amount of time required for audio energy introduced into a system (typically a room) to diminish, or decay by 60 decibels following the cessation of a stimulus signal used to excite the system — e.g., a balloon pop, gun shot or terminated pink noise. It is normally stated band-by-band for individual octave bands. By convention, decay times are normalized to the time required for 60 dB of decay at an observed rate of decay, regardless of the amplitude range actually measured. 60 dB decay time is often referred to as “RT60” or “T60", which is sometimes a source of confusion. And just to confuse things a little more ISO 3382 specifies that it should be called T20 or T30, where the “20" and “30” refer to the decay range actually measured. The main thing to remember is that all of the above refer to 60 dB decay time within a stated frequency range. When a single-number reverberation time is given, according to the ISO standard it should be the average of the reverberation The amount of time required for and/or represented by a measurement or other process. Often used interchangeably with Time Constant. For Smaart’s purposes, the term Overlap refers to the amount of data each successive FFT Frame shares in common with the one before. Overlapping FFT frames are analogous to shingles on a roof. When no overlap is used, each new FFT frame begins where the last one stopped, as beads on a string.